Back to Authors

Parikh, Vishal

https://orcid.org/0000-0003-4877-9044

Mayo Clinic

Unity Health System

Citations 2

Predictors of Gastrointestinal Bleeding in Patients Following Left Ventricular Assist Device Implantation: A Systematic Review and meta-analysis
Gangwani, Manesh Kumar , Aziz, Muhammad , Nawras, Ali, Priyanka, Fnu , Ahmed, Zohaib , Khan, Raja Samir , Qamar, Mohammad Aadil , Haroon, Fawad, Aziz, Abeer , Lee‐Smith, Wade , Ravi, Shri Jai Kirshan , Parikh, Vishal , Alyousif, Zakaria, Mahmood, Asif , Tariq, Raseen , Rai, Devesh , Aronow, Wilbert S. , Tariq, Raseen , Nawras, Ali T. , Mahmood, Asif

Future Cardiology | November 5, 2022 | Volume: 18 | Issue: 12 | Pages: 957-967

10.2217/fca-2022-0054 Get It

Abstract 13422: The Impact of Cardiac Resynchronization Therapy With Defibrillator in Patients With Nonischemic Cardiomyopathy
Patel, Harsh , Lee, Justin Z. , Parikh, Vishal , Feitell, Scott , Deshmukh, Abhishek , Thakkar, Samarthkumar , Kowlgi, Gurukripa N. , Kumar, Ashish , Parikh, Rohan, Dani, Sourbha S. , DeSimone, Christopher V.

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.13422 Get It

Introduction: Real-world data on the significance of adding a defibrillator to cardiac resynchronization therapy (CRT-D) in patients with nonischemic cardiomyopathy (NICM) are limited. Hypothesis: CRT-D is associated with a lower risk of mortality and heart failure (HF) readmissions compared to CRT-P in NICM. Methods: We identified patients with NICM who underwent CRT-D and CRT without an ICD (CRT-P) by analyzing the nationwide readmission database from October 2015- December 2018 and using appropriate ICD-10 CM codes. Propensity score matching was performed to adjust for the confounders. Kaplan Meier curves were utilized for time to event analysis. Cox proportional hazard regression was used to generate hazard ratios. All-cause mortality at 6 months was the primary outcome whereas readmission due to HF and any other cause at 6 months were defined as secondary outcomes. Results: Post-PSM, 3054 patients with NICM underwent CRT-P, and 2863 patients underwent CRT-D placement. CRT-D did not show any benefit over CRT-P in reducing all-cause mortality at 6 months (2.92% vs. 2.79%, HR: 0.84, 95% CI: 0.61-1.16, p=0.29). Similarly, there was no difference in terms of readmissions due to other causes among both groups of patients (36.25% vs. 31.85%, HR: 0.98, 95% CI: 0.89-1.08, p=0.77). However, patients with CRT-P implantations had a lower risk of HF readmissions compared to the CRT-D group (10.05% vs. 14.25%, HR: 0.67, 95% CI: 0.58-0.79, p<0.0001). Conclusions: The addition of a defibrillator to CRT failed to show a survival benefit in patients with NICM. Moreover, HF readmissions were higher in CRT-D patients compared to CRT-P.