Abstract Background Minimal clinically important differences (MCIDs) quantify the clinical relevance of quality of life results at the individual patient and group level. The aim of this study was to estimate the MCID for the Brief Fatigue Inventory (BFI) and the Worst and Usual Fatigue items in patients with brain or CNS cancer undergoing curative radiotherapy. Methods Data from a multi-site prospective registry was used. The MCID was calculated using distribution-based and anchor-based approaches. For the anchor-based approach, the fatigue item from the PROMIS-10 served as the anchor to determine if a patient improved, deteriorated, or had no change from baseline to end of treatment (EOT). We compared the unadjusted means on the BFI for the 3 groups to calculate the MCID. For the distribution-based approaches, we calculated the MCID as 0.5 SD of the scores and as 1.96 times the standard error of measurement. Results Three-hundred and fifty nine patients with brain or CNS tumors undergoing curative radiotherapy filled out the 9-item BFI at baseline and EOT. The MCID for the BFI was 1.33 (ranging from 0.99 to 1.70 across the approaches), 1.51 (ranging from 1.16 to 2.02) and 1.76 (ranging from 1.38 to 2.14) for the usual and worst fatigue items, respectively. Conclusions This study provides the MCID ranges for the BFI and Worst and Usual fatigue items, which will allow clinically meaningful conclusions to be drawn from BFI scores. These results can be used to select optimal treatments for patients with brain or CNS cancer or to interpret BFI scores from clinical trials.
Accurate Patient Alignment without Unnecessary Imaging Dose via Synthesizing Patient-specific 3D CT Images from 2D kV Images
Abstract In radiotherapy, 2D orthogonally projected kV images are used for patient alignment when 3D-on-board imaging(OBI) unavailable. But tumor visibility is constrained due to the projection of patient’s anatomy onto a 2D plane, potentially leading to substantial setup errors. In treatment room with 3D-OBI such as cone beam CT(CBCT), the field of view(FOV) of CBCT is limited with unnecessarily high imaging dose, thus unfavorable for pediatric patients. A solution to this dilemma is to reconstruct 3D CT from kV images obtained at the treatment position. Here, we propose a dual-models framework built with hierarchical ViT blocks. Unlike a proof-of-concept approach, our framework considers kV images as the solo input and can synthesize accurate, full-size 3D CT in real time(within milliseconds). We demonstrate the feasibility of the proposed approach on 10 patients with head and neck(H\&N) cancer using image quality(MAE:<45HU), dosimetric accuracy(Gamma passing rate(2%/2mm/10%):>97%) and patient position uncertainty(shift error:<0.4mm). The proposed framework can generate accurate 3D CT faithfully mirroring real-time patient position, thus significantly improving patient setup accuracy, keeping imaging dose minimum, and maintaining treatment veracity.
Technical note: Generalizable and promptable artificial intelligence model to augment clinical delineation in radiation oncology
Abstract Background Efficient and accurate delineation of organs at risk (OARs) is a critical procedure for treatment planning and dose evaluation. Deep learning‐based auto‐segmentation of OARs has shown promising results and is increasingly being used in radiation therapy. However, existing deep learning‐based auto‐segmentation approaches face two challenges in clinical practice: generalizability and human‐AI interaction. A generalizable and promptable auto‐segmentation model, which segments OARs of multiple disease sites simultaneously and supports on‐the‐fly human‐AI interaction, can significantly enhance the efficiency of radiation therapy treatment planning. Purpose Meta's segment anything model (SAM) was proposed as a generalizable and promptable model for next‐generation natural image segmentation. We further evaluated the performance of SAM in radiotherapy segmentation. Methods Computed tomography (CT) images of clinical cases from four disease sites at our institute were collected: prostate, lung, gastrointestinal, and head & neck. For each case, we selected the OARs important in radiotherapy treatment planning. We then compared both the Dice coefficients and Jaccard indices derived from three distinct methods: manual delineation (ground truth), automatic segmentation using SAM's ’segment anything’ mode, and automatic segmentation using SAM's ‘box prompt’ mode that implements manual interaction via live prompts during segmentation. Results Our results indicate that SAM's segment anything mode can achieve clinically acceptable segmentation results in most OARs with Dice scores higher than 0.7. SAM's box prompt mode further improves Dice scores by 0.1∼0.5. Similar results were observed for Jaccard indices. The results show that SAM performs better for prostate and lung, but worse for gastrointestinal and head & neck. When considering the size of organs and the distinctiveness of their boundaries, SAM shows better performance for large organs with distinct boundaries, such as lung and liver, and worse for smaller organs with less distinct boundaries, like parotid and cochlea. Conclusions Our results demonstrate SAM's robust generalizability with consistent accuracy in automatic segmentation for radiotherapy. Furthermore, the advanced box‐prompt method enables the users to augment auto‐segmentation interactively and dynamically, leading to patient‐specific auto‐segmentation in radiation therapy. SAM's generalizability across different disease sites and different modalities makes it feasible to develop a generic auto‐segmentation model in radiotherapy.
Clinical evaluation of fitness to drive in patients with brain metastases (P6.151)
RADT-25. IMPACT OF 18F-DOPA PET ON RADIATION TREATMENT PLANNING FROM PHASE II STUDY OF SHORT COURSE HYPOFRACTIONATED PROTON BEAM THERAPY FOR ELDERLY PATIENTS WITH GLIOBLASTOMA
Abstract PURPOSE 18F-DOPA is sensitive/specific for identifying areas of biologically aggressive disease for glioblastoma. We report the impact of 18F-DOPA on radiation treatment planning from a phase II study. METHODS Gross target volume (GTV) was defined by the boolean of high-risk PET (tumor/normal brain SUV > 2.0) and MRI T1 contrast enhancement (MRI-CE) including surgical cavity. The clinical target volume (CTV) included the GTV with 1cm margin. Using proton beam therapy, GTV ≤ 65 cc was treated with 25 (CTV), 30 (MRI-CE), and 35 (PET) GyE over 5 fractions with a simultaneous integrated boost. GTV > 65 cc received 30 (CTV), 35 (MRI-CE), and 40 (PET) GyE over 10 fractions. Radiation field design was compared to traditional 1.5cm CTV margin on MRI-CE. RESULTS Between May 2019 and October 2021, 39 patients were treated. The median MRI-CE tumor diameter was 5.2cm. The median PET volume was 7.9cc (range 0–64.9cc). The median MRI-CE volume was 35.1cc (range 8.6–114cc). High-risk PET was contained within: MRI-CE 18/39 (46%), MRI-CE + T2W FLAIR 13/39 (33%), MRI-CE + T2W FLAIR + outside GTV 4/39 (10%), outside GTV 2/39 (5%) and no uptake 2/39 (5%). Utilizing this planning technique, there was a 26% volume reduction in CTV to traditional 1.5 cm margin on MRI-CE. PET imaging in treatment planning allowed inclusion of high-risk disease that would have been excluded on traditional CTV in 23% of cases (range 1.6-33.8cc). PET was more predictive [HR 1.03 (95% CI 1.01, 1.05) p = 0.002] than MRI [HR 1.01 (95% CI 1.00, 1.03) p = 0.02] for death with each cc increasing risk of death by 3.1%. CONCLUSIONS The incorporation of 18F-DOPA in treatment planning yields a more targeted approach with reductions in both normal brain treated and risk of geographic miss compared to traditional CTV margins.
Modelling small block aperture in an in-house developed GPU-accelerated Monte Carlo-based dose engine for pencil beam scanning proton therapy
Abstract Purpose . To enhance an in-house graphic-processing-unit accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and materials . A module to simulate VPs passing through patient-specific aperture blocks was developed and integrated in VPMC based on simulation results of realistic particles (primary protons and their secondaries). To validate the aperture block module, VPMC was first validated by an opensource MC code, MCsquare, in eight water phantom simulations with 3 cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4 cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45 mm water equivalent thickness. Then, VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 c.c. with range of 0.4–43.3 c.c.). Finally, 3 typical patients were selected for robust optimization with aperture blocks using VPMC. Results . In the water phantoms, 3D gamma passing rate (2%/2 mm/10%) between VPMC and MCsquare was 99.71 ± 0.23%. In the patient geometries, 3D gamma passing rates (3%/2 mm/10%) between VPMC/MCsquare and RayStation MC were 97.79 ± 2.21%/97.78 ± 1.97%, respectively. Meanwhile, the calculation time was drastically decreased from 112.45 ± 114.08 s (MCsquare) to 8.20 ± 6.42 s (VPMC) with the same statistical uncertainties of ~0.5%. The robustly optimized plans met all the dose–volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 s and the subsequent on-the-fly ‘trial-and-error’ optimization procedure took only 71.4 s on average for the selected three patients. Conclusion . VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.
Beam mask and sliding window‐facilitated deep learning‐based accurate and efficient dose prediction for pencil beam scanning proton therapy
AbstractBackgroundAccurate and efficient dose calculation is essential for on‐line adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results in photon therapy. However, there is a scarcity of DL‐based dose prediction methods specifically designed for proton therapy. Successful dose prediction method for proton therapy should account for more challenging dose prediction problems in pencil beam scanning proton therapy (PBSPT) due to its sensitivity to heterogeneities.PurposeTo develop a DL‐based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on‐line adaptive proton therapy clinical decision and subsequent replanning.MethodsPBSPT plans of 103 prostate cancer patients (93 for training and the other 10 for independent testing) and 83 lung cancer patients (73 for training and the other 10 for independent testing) previously treated at our institution were included in the study, each with computed tomography scans (CTs), structure sets, and plan doses calculated by the in‐house developed Monte‐Carlo dose engine (considered as the ground truth in the model training and testing). For the ablation study, we designed three experiments corresponding to the following three methods: (1) Experiment 1, the conventional region of interest (ROI) (composed of targets and organs‐at‐risk [OARs]) method. (2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. (3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D‐Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates with a criterion of 3%/3 mm/10%, and dice coefficients for the structures enclosed by the iso‐dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency.ResultsCompared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices (for lung cancer, CTV D98 absolute deviation: 0.74 ± 0.18 vs. 0.57 ± 0.21 vs. 0.54 ± 0.15 Gy[RBE], ROI vs. beam mask vs. sliding window methods, respectively). For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method improved the passing rates in these regions and the sliding window method further improved them (for prostate cancer, targets: 96.93% ± 0.53% vs. 98.88% ± 0.49% vs. 99.97% ± 0.07%, BODY: 86.88% ± 0.74% vs. 93.21% ± 0.56% vs. 95.17% ± 0.59%). A similar trend was also observed for the dice coefficients. This trend was especially remarkable for relatively low prescription isodose lines (for lung cancer, 10% isodose line dice: 0.871 ± 0.027 vs. 0.911 ± 0.023 vs. 0.927 ± 0.017). The dose predictions for all the testing cases were completed within 0.25 s.ConclusionsAn accurate and efficient deep learning‐augmented proton dose prediction framework has been developed for PBSPT, which can predict accurate dose distributions not only inside but also outside ROI efficiently. The framework can potentially further reduce the initial planning and adaptive replanning workload in PBSPT.
Radiotherapy toxicity prediction using knowledge-constrained generalized linear model
Phase II study of short course hypofractionated proton beam therapy incorporating 18F-DOPA-PET/MRI for elderly patients with newly diagnosed glioblastoma.
2002 Background: Elderly patients with glioblastoma have a poor prognosis with phase III trials reporting median overall survival (OS) and global time to deterioration of 6–9 and 1.2 months respectively. 18F-DOPA (3,4-dihydroxy-6-[18F]-fluoro-L-phenylalanine) positron emission tomography (PET) is sensitive and specific for identifying regions of high density and biologically aggressive glioblastoma. Proton beam therapy (PBT) can spare more healthy tissue that may improve quality of life for this patient population. With improved targeting of disease along with dosimetric advantages of PBT, this phase II trial tested whether hypofractionated PBT can offer both improved survival and quality of life. Methods: Patients with newly diagnosed glioblastoma aged ≥65 years without contraindications to 18F-DOPA were eligible. Target volumes were defined by PET (tumor/normal brain SUV ≥2.0) and MRI areas of contrast enhancement including surgical cavity. Patients received dose escalated hypofractionated PBT of 35-40 GyE to PET/MRI over 5-10 treatments with 10 mm margin. Patients received concurrent/adjuvant temozolomide. With an alpha of 0.1, 18 of 39 patients would be required to be alive at 12 months for the study to be considered a success. Kaplan-Meier/Cox regression analysis was performed for progression free survival (PFS) and OS. Toxicities were evaluated with CTCAE v4.0. Patients completed EORTC BN20, QLQ-C30, and MMSE questionnaires. Time to deterioration, defined as a 10-point decrease in the score of the function domain or 10-point increase in score of symptom domain, was evaluated. Results: Between 5/2019-6/2021, 43 patients were enrolled, with 4 patients withdrawing due to progression/insurance denial prior to beginning protocol therapy. The median age was 70.2 yrs. and median follow-up was 12.5 months. MGMT methylation was present in 13 (33%). Tumors were multifocal in 10 (26%) and unifocal in 29 (74%). The primary endpoint was met with median PFS/OS was 6.5/12.9 months for all patients and for MGMT methylated patients 11.9/29.8 months respectively. Grade 3 baseline adjusted treatment related adverse events included 1 (3%) confusion, 2 (5%) fatigue, and 1 (3%) seizure. There were no grade 4/5 events. Multivariate analysis revealed MGMT unmethylated, ECOG 2 and biopsy only patients had worse survival. PET volume was more predictive than MRI volume for OS with PET volume>26 cc having a hazard ratio of 3.7. The median time to global deterioration per QLC-C30 was 6.3 months. Conclusions: This phase II trial incorporating 18F-DOPA PET-guided dose escalated hypofractionated proton beam treatment for elderly patients with glioblastoma met its primary endpoint for improved OS and patient reported quality of life compared to historical controls. Further investigation is warranted. Clinical trial information: NCT03778294 .
Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery
AbstractBackgroundMechanical accuracy should be verified before implementing a proton stereotactic radiosurgery (SRS) program. Linear accelerator (Linac)‐based SRS systems often use electronic portal imaging devices (EPIDs) to verify beam isocentricity. Because proton therapy systems do not have EPID, beam isocentricity tests of proton SRS may still rely on films, which are not efficient.PurposeTo validate that our proton SRS system meets mechanical precision requirements and to present an efficient method to evaluate the couch and gantry's rotational isocentricity for our proton SRS system.MethodsA dedicated applicator to hold brass aperture for proton SRS system was designed. The mechanical precision of the system was tested using a metal ball and film for 11 combinations of gantry and couch angles. A more efficient quality assurance (QA) procedure was developed, which used a scintillator device to replace the film. The couch rotational isocentricity tests were performed using orthogonal kV x‐rays with the couch rotated isocentrically to five positions (0°, 315°, 270°, 225°, and 180°). At each couch position, the distance between the metal ball in kV images and the imaging isocenter was measured. The gantry isocentricity tests were performed using a cone‐shaped scintillator and proton beams at five gantry angles (0°, 45°, 90°, 135°, and 180°), and the isocenter position and the distance of each beam path to the isocenter were obtained. Daily QA procedure was performed for 1 month to test the robustness and reproducibility of the procedure.ResultsThe gantry and couch rotational isocentricity exhibited sub‐mm precision, with most measurements within ±0.5 mm. The 1‐month QA results showed that the procedure was robust and highly reproducible to within ±0.2 mm. The gantry isocentricity test using the cone‐shaped scintillator was accurate and sensitive to variations of ±0.2 mm. The QA procedure was efficient enough to be completed within 30 min. The 1‐month isocentricity position variations were within 0.5 mm, which demonstrating that the overall proton SRS system was stable and precise.ConclusionThe proton SRS Winston–Lutz QA procedure using a cone‐shaped scintillator was efficient and robust. We were able to verify radiation delivery could be performed with sub‐mm mechanical precision.