Back to Authors

Bruce, Charles J.

https://orcid.org/0000-0002-7481-5793

Mayo Clinic

Mayo Clinic in Florida

Citations 43

Endocardial Device Leads in Patients with Patent Foramen Ovale: Echocardiographic Correlates of Stroke/TIA and Mortality
Ponamgi, Shiva , Vaidya, Vaibhav R. , Noheria, Amit , Hodge, David O. , Slusser, Joshua P. , Ammash, Naser M., Friedman, Paul A. , Asirvatham, Samuel J. , Ponamgi, Shiva P , Bruce, Charles J. , DeSimone, Christopher V. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | December 12, 2016 | Volume: 40 | Issue: 3 | Pages: 310-322

10.1111/pace.12985 Get It

BackgroundEchocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO.MethodsIn 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow‐up echocardiogram.ResultsOf 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow‐up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time‐dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447–2.189, P < 0.0001), or increase in RVSP by >10 mm Hg (HR 2.018, 95% CI 1.593–2.556, P < 0.0001), or maximum RVSP in follow‐up (HR 1.432, 95% CI 1.351–1.516, P < 0.0001). A significant increase (P < 0.001) in TR was also noted during follow‐up.ConclusionsIn patients with CIED and PFO, structural and hemodynamic echocardiographic markers did not predict future stroke/TIA. However, a significantly higher TR or RVSP was associated with higher mortality.
Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG
Sapir, Yehu , Dugan, Jennifer , Ackerman, Michael J. , Asirvatham, Samuel J. , Striemer, Bryan L., Bukartyk, Jan , Bennet, Kevin E. , Ladewig, Dorothy J., Gilles, Emily J., Sadot, Dan , Geva, Amir B. , Friedman, Paul A. , Dillon, John J, Dugan, Jennifer L, Bruce, Charles J. , Attia, Zachi I. , DeSimone, Christopher V. , Dillon, John J., Somers, Virend K. , Scott, Christopher G. , Asirvatham, Samuel J

Journal of the American Heart Association | January 25, 2016 | Volume: 5 | Issue: 1 | Pages: No page available

10.1161/jaha.115.002746 Get It

Background Hyper‐ and hypokalemia are clinically silent, common in patients with renal or cardiac disease, and are life threatening. A noninvasive, unobtrusive, blood‐free method for tracking potassium would be an important clinical advance. Methods and Results Two groups of hemodialysis patients (development group, n=26; validation group, n=19) underwent high‐resolution digital ECG recordings and had 2 to 3 blood tests during dialysis. Using advanced signal processing, we developed a personalized regression model for each patient to noninvasively calculate potassium values during the second and third dialysis sessions using only the processed single‐channel ECG . In addition, by analyzing the entire development group's first‐visit data, we created a global model for all patients that was validated against subsequent sessions in the development group and in a separate validation group. This global model sought to predict potassium, based on the T wave characteristics, with no blood tests required. For the personalized model, we successfully calculated potassium values with an absolute error of 0.36±0.34 mmol/L (or 10% of the measured blood potassium). For the global model, potassium prediction was also accurate, with an absolute error of 0.44±0.47 mmol/L for the training group (or 11% of the measured blood potassium) and 0.5±0.42 for the validation set (or 12% of the measured blood potassium). Conclusions The signal‐processed ECG derived from a single lead can be used to calculate potassium values with clinically meaningful resolution using a strategy that requires no blood tests. This enables a cost‐effective, noninvasive, unobtrusive strategy for potassium assessment that can be used during remote monitoring.
“The Balloon Plug Concept” for Tricuspid Valve Repair Ex Vivo Proof of Concept
Bajona, Pietro, Salizzoni, Stefano , Vandenberghe, Stijn , Speziali, Giovanni, Zehr, Kenton J., Bruce, Charles J.

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | January 27, 2015 | Volume: 10 | Issue: 1 | Pages: 27-32

10.1097/imi.0000000000000124 Get It

Objective Functional tricuspid regurgitation (TR) is recognized as a significant cause of morbidity and mortality in cardiothoracic surgery. We hypothesized that a variably expandable, transvalvular balloon mounted on a catheter could be percutaneously inserted and fixed to the right ventricle apex. This novel approach could provide a minimally invasive way to eliminate clinically relevant TR caused by annular dilatation. This study was performed to test the ex vivo hemodynamic effects and the feasibility of the “balloon plug concept.” Methods Twenty harvested calf tricuspid valves were placed in a mechanical simulator. Tricuspid regurgitation was created by annular stretching and displacement of the papillary muscles so as to create central TR. A flexible catheter with a 4-cm–long, soft, fusiform balloon was positioned across the valve so that the balloon was suspended centrally across the valve annular plane. After activating the mechanical ventricle, data were collected with balloon inflation volumes of saline from 5 to 20 mL. Transvalvular pressure gradients and leaflet mechanics were evaluated with incremental inflation. Results In all cases, 5-mL inflation did not significantly reduce TR and 20-mL inflation caused obstruction to antegrade flow (mean transvalvular gradient > 4 mm Hg). Inflation between 10 and 15 mL caused significant reduction in TR with acceptable transvalvular gradients (<3 mm Hg). Conclusions The balloon plug concept showed promising ex vivo hemodynamic results. In vivo investigations are warranted to evaluate percutaneous techniques, thrombogenicity, and effects of repeated balloon-leaflet contact on valve integrity.
Anatomical aortic reconstruction in Marfan disease: dismantling of a hybrid repair†
Quintana, Eduard , Sabaté-Rotés, Anna , Pochettino, Alberto , Bruce, Charles, Sabate Rotes, Anna, Bruce, Charles J.

European Journal of Cardio-Thoracic Surgery | December 4, 2014 | Volume: 48 | Issue: 3 | Pages: 507-509

10.1093/ejcts/ezu465 Get It

Filter Neuroprotection of a Single Patent Internal Carotid Artery During Transapical Aortic Valve Implantation
Sarangi, Siddharth, Bresnahan, John F., Mario, Gössl, Suri, Rakesh M. , Bruce, Charles J.

Journal of Cardiac Surgery | April 22, 2014 | Volume: 30 | Issue: 3 | Pages: 260-262

10.1111/jocs.12347 Get It

CT and MRI Assessment of the Aortic Root and Ascending Aorta
Freeman, Laura A., Young, Phillip M. , Foley, Thomas A. , Williamson, Eric E. , Greason, Kevin L. , Bruce, Charles J.

American Journal of Roentgenology | May 23, 2013 | Volume: 200 | Issue: 6 | Pages: W581-W592

10.2214/ajr.12.9531 Get It

Dyssynchrony Indices To Predict Response to Cardiac Resynchronization Therapy
Miyazaki, Chinami , Redfield, Margaret M. , Powell, Brian D. , Lin, Grace, Herges, Regina M., Hodge, David O. , Olson, Lyle J. , Hayes, David L. , Espinosa, Raúl E. , Rea, Robert F., Nelson, Susan M., Miller, Fletcher A., Oh, Jae K. , Bruce, Charles J.

Circulation: Heart Failure | July 21, 2010 | Volume: 3 | Issue: 5 | Pages: 565-573

10.1161/circheartfailure.108.848085 Get It

Background— Whether mechanical dyssynchrony indices predict reverse remodeling (RR) or clinical response to cardiac resynchronization therapy (CRT) remains controversial. This prospective study evaluated whether echocardiographic dyssynchrony indices predict RR or clinical response after CRT. Methods and Results— Of 184 patients with heart failure with anticipated CRT who were prospectively enrolled, 131 with wide QRS and left ventricular ejection fraction <35% had 6-month follow-up after CRT implantation. Fourteen dyssynchrony indices (feasibility) by M-mode (94%), tissue velocity (96%), tissue Doppler strain (92%), 2D speckle strain (65% to 86%), 3D echocardiography (79%), and timing intervals (98%) were evaluated. RR (end-systolic volume reduction ≥15%) occurred in 55% and more frequently in patients without (71%) than in patients with (42%) ischemic cardiomyopathy ( P =0.002). Overall, only M-mode, tissue Doppler strain, and total isovolumic time had a receiver operating characteristic area under the curve (AUC) greater than the line of no information, but none of these were strongly predictive of RR (AUC, 0.63 to 0.71). In nonischemic cardiomyopathy, no dyssynchrony index predicted RR. In ischemic cardiomyopathy, M-mode (AUC, 0.67), tissue Doppler strain (AUC, 0.79), and isovolumic time (AUC, 0.76) -derived indices predicted RR ( P <0.05 for all), although the incremental value was modest. No indices predicted clinical response assessed by Minnesota Living with Heart Failure Questionnaire, 6-minute walk distance, and peak oxygen consumption. Conclusions— These findings are consistent with the Predictors of Response to CRT study and do not support use of these dyssynchrony indices to guide use of CRT.
Changes in Left and Right Ventricular Mechanics During the Mueller Maneuver in Healthy Adults
Koshino, Yuki, Villarraga, Hector R. , Orban, Marek , Pressman, Gregg S. , Leinveber, Pavel , Saleh, Haydar K., Konečný, Tomáš , Kára, Tomáš, Bruce, Charles J. , Somers, Virend K. , López-Jiménez, Francisco

Circulation: Cardiovascular Imaging | February 17, 2010 | Volume: 3 | Issue: 3 | Pages: 282-289

10.1161/circimaging.109.901561 Get It

Background— Obstructive sleep apnea is highly prevalent in patients with cardiovascular disease and has detrimental effects on systolic and diastolic function of the ventricles. In this research, the changes in strain (S) and strain rate (SR) during the performance of the Mueller maneuver (MM) in an effort to better understand how negative intrathoracic pressures affect ventricular mechanics. Methods and Results— The MM was performed to maintain a target intrathoracic pressure of −40 mm Hg. Echocardiography was used to measure various parameters of cardiac structure and function. Myocardial deformation measurements were performed using tissue speckle tracking. Twenty-four healthy subjects (9 women; mean age, 30�6 years) were studied. Global left ventricular longitudinal S in systole and SR in early filling were significantly decreased during the MM (S: baseline, −17.0�1.6%; MM, −14.5�2.2%; P <0.0001, SR: baseline, 1.09�0.20 s −1 ; MM, 0.92�0.21 s −1 ; P =0.01). Global right ventricular longitudinal S was also significantly decreased during the MM (baseline, −22.0�3.1%; MM, −17.2�2.5%; P <0.0001), as was global right ventricular longitudinal systolic SR (baseline, −1.34�0.35 s −1 ; MM, −1.02�0.21 s −1 ; P =0.0006). Conclusions— Left ventricular and right ventricular longitudinal deformation are significantly reduced during the MM. These results suggest that negative intrathoracic pressure during apnea may contribute to changes in myocardial mechanics. These results could help explain the observed changes in left ventricular and right ventricular mechanics in patients with obstructive sleep apnea.
Right-Sided Valve Disease Deserves a Little More Respect
Connolly, Heidi M. , Bruce, Charles J.

Circulation | May 26, 2009 | Volume: 119 | Issue: 20 | Pages: 2726-2734

10.1161/circulationaha.108.776021 Get It

Mechanisms of Recurrent Functional Mitral Regurgitation After Mitral Valve Repair in Nonischemic Dilated Cardiomyopathy
Lee, Alex Pui‐Wai , Kubo, Spencer H. , Bolling, Steven F., Park, Seung W., Oh, Jae K. , Acker, Michael G. , Bruce, Charles J.

Circulation | May 4, 2009 | Volume: 119 | Issue: 19 | Pages: 2606-2614

10.1161/circulationaha.108.796151 Get It

Background— Recurrent functional mitral regurgitation (MR) has been reported after mitral valve repair with annuloplasty in patients with dilated cardiomyopathy, but the mechanism is not understood completely. The authors sought to identify abnormalities of the mitral valve and left ventricle that are associated with recurrent MR after mitral annuloplasty. Method and Results— In 104 patients with idiopathic dilated cardiomyopathy who underwent annuloplasty for functional MR, basal mitral anterior leaflet angle, distal mitral anterior leaflet angle (ALA tip ), posterior leaflet angle, coaptation depth, tenting area, mitral annular dimensions, left ventricular volumes, and MR severity were quantified by echocardiography before surgery and at 6-month intervals after it. Compared with patients without MR recurrence (n=79), patients with recurrent MR (defined as ≥2+) (n=25) had greater ALA tip ( P <0.001) and basal mitral anterior leaflet angle ( P <0.001), greater coaptation depth and tenting area ( P <0.001), larger left ventricular volumes ( P <0.001), and worse left ventricular ejection fraction ( P <0.05) but similar mitral annular dimensions and postoperative exaggeration in posterior leaflet angle. Multivariable analysis identified postoperative ALA tip as the major determinant of postoperative MR. Receiver operator characteristic curves identified preoperative ALA tip as the best predictor of MR recurrence (area under curve, 0.98). For ALA tip >25°, the sensitivity, specificity, and positive and negative predictive values in predicting recurrent MR were 88%, 94%, 82%, and 93%, respectively. Three distinct patterns of anterior leaflet tethering (minimal, basal, and distal) with an increasing risk of recurrent MR were identified. Conclusions— Posterior leaflet tethering is invariable after mitral annuloplasty, rendering postoperative mitral competence highly dependent on distal anterior leaflet mobility.