AbstractBackgroundTransvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS).Methods and resultsWe designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof‐of‐concept and 5 additional acute canine experiments.The TS device recorded ventricular and atrial electrograms. The median amplitude of near‐field ventricular electrograms was 3.3 mA (IQR 2.0–4.3) and of near‐field atrial electrograms was 2.1 mA (IQR 1.3–2.2). The median ventricular threshold (N = 30) was 1.1 mA (IQR 0.7–3.1) at a median pulse width of 0.5 ms (IQR 0.5–0.5). The median atrial threshold (N = 10) was 2.4 mA (IQR 1.1–7.8) at a median pulse width of 0.5 ms (IQR 0.5–0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications.ConclusionsThis study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.
Irreversible electroporation for the treatment of cardiac arrhythmias
Among patients undergoing cardioversion for atrial fibrillation, the presence of left ventricular thrombus is a relatively uncommon and challenging clinical dilemma. While left atrial appendage thrombus is a contraindication to cardioversion, there is paucity of data regarding the safety of cardioversion in with the presence of left ventricular apical thrombus. Also, thrombus characteristics such as protrusion and mobility on echocardiography are known risk factors for systemic embolism. In this article, we present a case highlighting the management of atrial fibrillation in the setting of left ventricular dysfunction, acute heart failure, and echocardiographic evidence of acute left ventricular apical thrombus.
Response by Vaidya et al to Letter Regarding Article, “Burden of Arrhythmia in Pregnancy”
BackgroundEchocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO.MethodsIn 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow‐up echocardiogram.ResultsOf 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow‐up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time‐dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447–2.189, P < 0.0001), or increase in RVSP by >10 mm Hg (HR 2.018, 95% CI 1.593–2.556, P < 0.0001), or maximum RVSP in follow‐up (HR 1.432, 95% CI 1.351–1.516, P < 0.0001). A significant increase (P < 0.001) in TR was also noted during follow‐up.ConclusionsIn patients with CIED and PFO, structural and hemodynamic echocardiographic markers did not predict future stroke/TIA. However, a significantly higher TR or RVSP was associated with higher mortality.
Electrophysiologic Characteristics of Ventricular Arrhythmias Arising from the Aortic Mitral Continuity—Potential Role of the Conduction System
Arrhythmogenic Substrate of Ventricular Arrhythmias at the AMCIntroductionCatheter ablation of ventricular arrhythmia (VA) at the fibrous aortic mitral continuity (AMC) has been described, yet the nature of the arrhythmogenic substrate remains unknown.MethodsProcedural records of 528 consecutive patients undergoing ablation of VA at Mayo Clinic, Rochester, MN, were reviewed. The electrocardiographic and electrophysiologic characteristics of patients with successful ablation at the AMC were analyzed to characterize the underlying arrhythmogenic substrate.ResultsOf the 21 patients (mean age 53.2 ± 13.4 years, 47.6% male) who underwent ablation of VA at the AMC with acute success, prepotentials (PPs) were found at the ablation sites preceding the ventricular electrogram (VEGM) during arrhythmias in 13 (61.9%) patients and during sinus rhythm in 7 (53.8%) patients. VAs with PPs were associated with a significantly higher burden of premature ventricular complexes (PVCs; 26.1 ± 10.9% vs. 14.9 ± 10.1%, P = 0.03), shorter VEGM to QRS intervals (9.0 ± 28.5 milliseconds vs. 33.1 ± 8.8 milliseconds, P = 0.03), lower pace map scores (8.7 ± 1.6 vs. 11.4 ± 0.8, P = 0.001), and a trend toward shorter V‐H intervals during VA (32.1 ± 38.6 milliseconds vs. 76.3 ± 11.1 milliseconds, P = 0.06) as compared to those without PP. A strong and positive correlation was found between V‐H interval and QRS duration during arrhythmia in those with PPs (B = 2.11, R2 = 0.97, t = 13.7, P < 0.001) but not in those without PPs.ConclusionLocal EGM characteristics and relative activation time of the His bundle suggest the possibility of conduction tissue as the origin for VA arising from the fibrous AMC. Specific identification and targeting of PPs when ablating VAs at this location may improve procedural success.
Response to Letters Regarding Article, “Stroke or Transient Ischemic Attack in Patients With Transvenous Pacemaker or Defibrillator and Echocardiographically Detected Patent Foramen Ovale”
Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device
Electromagnetic Interference with Ventricular Assist DeviceBackgroundHemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.MethodsImpella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.ResultsSevere EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P < 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance‐only mapping with manual annotation.ConclusionConcurrent use of MFD caused EMI to prevent acquisition of points with magnet‐based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance‐only mapping are 2 methods to resolve EMI.