Back to Authors

Gorny, Krzysztof R.

https://orcid.org/0000-0001-8785-3070

Mayo Clinic

Mayo Clinic

Citations 23

Novel Focal Therapeutic Hypothermia Device for Treatment of Acute Neurologic Injury: Large Animal Safety and Efficacy Trial
Perry, Avital , Graffeo, Christopher S. , Ding, Yong Hong, Jakaitis, Daniel R. , Lu, Aiming , Rodgers, Seth, Kreck, Thomas, Hoofer, Kelly, Gorny, Krzysztof R. , Kadirvel, Ramanathan , Kallmes, David F. , Carlstrom, Lucas P. , Dai, Daying , Ding, Yong H, Ding, Yonghong

Journal of Neurological Surgery Part B: Skull Base | March 9, 2021 | Volume: 83 | Issue: 02 | Pages: 203-209

10.1055/s-0040-1721818 Get It

Abstract Objective Therapeutic hypothermia is a potentially powerful and controversial clinical tool for neuroprotection following acute neurologic pathology, particularly vascular injury. Indeed, therapeutic hypothermia remains a standard of care for postcardiac arrest ischemia and acute neonatal hypoxic-ischemic encephalopathy, improving both survival and outcomes. Although therapeutic hypothermia remains promising for cellular and systems-based neuronal protection in other neurologic injury states, the systemic side effects have limited clinical utility, confounded analysis of potential neurologic benefits, and precluded the completion of meaningful clinical trials. Methods To address such limitations, we developed and tested a novel, minimally invasive, neurocritical care device that employs continuous circulation of cold saline through the pharyngeal region to deliver focal cerebrovascular cooling. We conducted a preclinical safety and efficacy trial in six adult porcine animals to assess the validity and functionality of the NeuroSave device, and assess cooling potential following middle cerebral artery occlusion (n = 2). Results NeuroSave consistently lowered brain parenchymal temperature by a median of 9°C relative to core temperature within 60 minutes of initiation, including in ischemic cerebral parenchyma. The core body temperature experienced a maximal reduction of 2°C, or 5% of body temperature, with no associated adverse effects identified. Conclusion The present study uses a large animal preclinical model to demonstrate the safety and efficacy of a novel, noninvasive device for the induction of robust and systemically safe hypothermia within the brain.
MRI and tractography techniques to localize the ventral intermediate nucleus and dentatorubrothalamic tract for deep brain stimulation and MR-guided focused ultrasound: a narrative review and update
Lee, Kendall H. , Klassen, Bryan T. , Blezek, Daniel J. , Goyal, Abhinav , Shah, Bhavya , Gorny, Krzysztof R. , Lehman, Vance T. , Huston, John , Kaufmann, Timothy J.

Neurosurgical Focus | July 1, 2020 | Volume: 49 | Issue: 1 | Pages: E8

10.3171/2020.4.focus20170 Get It

The thalamic ventral intermediate nucleus (VIM) can be targeted for treatment of tremor by several procedures, including deep brain stimulation (DBS) and, more recently, MR-guided focused ultrasound (MRgFUS). To date, such targeting has relied predominantly on coordinate-based or atlas-based techniques rather than directly targeting the VIM based on imaging features. While general regional differences of features within the thalamus and some related white matter tracts can be distinguished with conventional imaging techniques, internal nuclei such as the VIM are not discretely visualized. Advanced imaging methods such as quantitative susceptibility mapping (QSM) and fast gray matter acquisition T1 inversion recovery (FGATIR) MRI and high-field MRI pulse sequences that improve the ability to image the VIM region are emerging but have not yet been shown to have reliability and accuracy to serve as the primary method of VIM targeting. Currently, the most promising imaging approach to directly identify the VIM region for clinical purposes is MR diffusion tractography. In this review and update, the capabilities and limitations of conventional and emerging advanced methods for evaluation of internal thalamic anatomy are briefly reviewed. The basic principles of tractography most relevant to VIM targeting are provided for familiarization. Next, the key literature to date addressing applications of DTI and tractography for DBS and MRgFUS is summarized, emphasizing use of direct targeting. This literature includes 1-tract (dentatorubrothalamic tract [DRT]), 2-tract (pyramidal and somatosensory), and 3-tract (DRT, pyramidal, and somatosensory) approaches to VIM region localization through tractography. The authors introduce a 3-tract technique used at their institution, illustrating the oblique curved course of the DRT within the inferior thalamus as well as the orientation and relationship of the white matter tracts in the axial plane. The utility of this 3-tract tractography approach to facilitate VIM localization is illustrated with case examples of variable VIM location, targeting superior to the anterior commissure–posterior commissure plane, and treatment in the setting of pathologic derangement of thalamic anatomy. Finally, concepts demonstrated with these case examples and from the prior literature are synthesized to highlight several potential advantages of tractography for VIM region targeting.
Magnetic Resonance–Guided Prostate Ablation
Woodrum, David A. , Gorny, Krzysztof R. , Mynderse, Lance A. , Kawashima, Akira

Seminars in Interventional Radiology | December 2, 2019 | Volume: 36 | Issue: 05 | Pages: 351-366

10.1055/s-0039-1697001 Get It

AbstractIn 2019, the American Cancer Society (ACS) estimates that 174,650 new cases of prostate cancer will be diagnosed and 31,620 will die due to the prostate cancer in the United States. Prostate cancer is often managed with aggressive curative intent standard therapies including radiotherapy or surgery. Regardless of how expertly done, these standard therapies often bring significant risk and morbidity to the patient's quality of life with potential impact on sexual, urinary, and bowel functions. Additionally, improved screening programs, using prostatic-specific antigen and transrectal ultrasound-guided systematic biopsy, have identified increasing numbers of low-risk, low-grade “localized” prostate cancer. The potential, localized, and indolent nature of many prostate cancers presents a difficult decision of when to intervene, especially within the context of the possible comorbidities of aggressive standard treatments. Active surveillance has been increasingly instituted to balance cancer control versus treatment side effects; however, many patients are not comfortable with this option. Although active debate continues on the suitability of either focal or regional therapy for the low- or intermediate-risk prostate cancer patients, no large consensus has been achieved on the adequate management approach. Some of the largest unresolved issues are prostate cancer multifocality, limitations of current biopsy strategies, suboptimal staging by accepted imaging modalities, less than robust prediction models for indolent prostate cancers, and safety and efficiency of the established curative therapies following focal therapy for prostate cancer. In spite of these restrictions, focal therapy continues to confront the current paradigm of therapy for low- and even intermediate-risk disease. It has been proposed that early detection and proper characterization may play a role in preventing the development of metastatic disease. There is level-1 evidence supporting detection and subsequent aggressive treatment of intermediate- and high-risk prostate cancer. Therefore, accurate assessment of cancer risk (i.e., grade and stage) using imaging and targeted biopsy is critical. Advances in prostate imaging with MRI and PET are changing the workup for these patients, and advances in MR-guided biopsy and therapy are propelling prostate treatment solutions forward faster than ever.
Abstract QS35: Clinical and Radiological Safety of Retained Implantable Doppler Devices After Free Flaps
Kreutz‐Rodrigues, Lucas , Frick, Matthew A., Gorny, Krzysztof R. , Carlsen, Brian T. , Bakri, Karim , Mardini, Samir

Plastic and Reconstructive Surgery - Global Open | April 29, 2019 | Volume: 7 | Issue: 4S | Pages: 125-126

10.1097/01.gox.0000558455.34144.2d Get It

Laser ablation for mesial temporal epilepsy: a multi-site, single institutional series
Zimmerman, Richard S. , Brinkmann, Benjamin H. , Tatum, William O. , Crepeau, Amy Z. , Woodrum, David A. , Gorny, Krzysztof R. , Felmlee, Joel P. , Watson, Robert E. , Trenerry, Max R., Marsh, W. Richard , Wharen, Robert E. , Hoxworth, Joseph M. , Vibhute, Prasanna , Brinkmann, Benjamin H , Grewal, Sanjeet S. , Worrell, Gregory A. , Gupta, Vivek , Kaufmann, Timothy J. , Gompel, Jamie J. Van

Journal of Neurosurgery | July 6, 2018 | Volume: No volume available | Issue: No issue available | Pages: 1-8

10.3171/2018.2.jns171873 Get It

OBJECTIVE Although it is still early in its application, laser interstitial thermal therapy (LiTT) has increasingly been employed as a surgical option for patients with mesial temporal lobe epilepsy. This study aimed to describe mesial temporal lobe ablation volumes and seizure outcomes following LiTT across the Mayo Clinic’s 3 epilepsy surgery centers. METHODS This was a multi-site, single-institution, retrospective review of seizure outcomes and ablation volumes following LiTT for medically intractable mesial temporal lobe epilepsy between October 2011 and October 2015. Pre-ablation and post-ablation follow-up volumes of the hippocampus were measured using FreeSurfer, and the volume of ablated tissue was also measured on intraoperative MRI using a supervised spline-based edge detection algorithm. To determine seizure outcomes, results were compared between those patients who were seizure free and those who continued to experience seizures. RESULTS There were 23 patients who underwent mesial temporal LiTT within the study period. Fifteen patients (65%) had left-sided procedures. The median follow-up was 34 months (range 12–70 months). The mean ablation volume was 6888 mm 3 . Median hippocampal ablation was 65%, with a median amygdala ablation of 43%. At last follow-up, 11 (48%) of these patients were seizure free. There was no correlation between ablation volume and seizure freedom (p = 0.69). There was also no correlation between percent ablation of the amygdala (p = 0.28) or hippocampus (p = 0.82) and seizure outcomes. Twelve patients underwent formal testing with computational visual fields. Visual field changes were seen in 67% of patients who underwent testing. Comparing the 5 patients with clinically noticeable visual field deficits to the rest of the cohort showed no significant difference in ablation volume between those patients with visual field deficits and those without (p = 0.94). There were 11 patients with follow-up neuropsychological testing. Within this group, verbal learning retention was 76% in the patients with left-sided procedures and 89% in those with right-sided procedures. CONCLUSIONS In this study, there was no significant correlation between the ablation volume after LiTT and seizure outcomes. Visual field deficits were common in formally tested patients, much as in patients treated with open temporal lobectomy. Further studies are required to determine the role of amygdalohippocampal ablation.
Development of a robust MRI fiducial system for automated fusion of MR‐US abdominal images
Favazza, Christopher , Gorny, Krzysztof R. , Callstrom, Matthew R. , Kurup, A. Nicholas , Washburn, Michael J., Trester, Pamela S. , Fowler, Charles L., Hangiandreou, Nicholas J., Favazza, Christopher P, Kurup, Anil N, Kurup, Anil N

Journal of Applied Clinical Medical Physics | May 22, 2018 | Volume: 19 | Issue: 4 | Pages: 261-270

10.1002/acm2.12352 Get It

AbstractWe present the development of a two‐component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto‐segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center‐of‐mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm‐measured inter‐marker spacings and actual separation distances were 0.53 ± 0.36 mm. “Proof‐of‐concept” automatic MR‐US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath‐hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences.
Safety of Laser Interstitial Thermal Therapy in Patients With Pacemakers
Gorny, Krzysztof R. , Favazza, Christopher , Watson, Robert E. , Favazza, Christopher P, Grewal, Sanjeet S. , Kaufmann, Timothy J. , Gompel, Jamie J. Van

Operative Neurosurgery | February 10, 2018 | Volume: 15 | Issue: 5 | Pages: E69-E72

10.1093/ons/opx292 Get It

Abstract BACKGROUND AND IMPORTANCE Laser interstitial thermal therapy (LiTT) has increasingly been used as a treatment option for medically refractory epilepsy, tumors, and radiation necrosis. The use of LiTT requires intraoperative magnetic resonance (MR) thermography. This can become an issue in patients with other implanted therapeutic devices such as pacemakers and vagal nerve stimulators due to concerns regarding increases in the specific absorption rate (SAR). This is a technical case report demonstrating a successfully and safely performed LiTT in a 1.5-T magnetic resonance imaging (MRI) in a patient with a pacemaker for mesial temporal sclerosis. CLINICAL PRESENTATION An 83-yr-old gentleman who had an implanted cardiac pacemaker presented with medically intractable epilepsy and was confirmed to have mesial temporal sclerosis on imaging. Video electroencephalography demonstrated concordant ipsilateral seizures and semiology. He underwent LiTT for ablation of the mesial temporal lobe. This was performed with the below described protocol with a cardiology nurse monitoring the patient's cardiac condition and a physicist monitoring SAR, and MR imaging quality without any adverse events. CONCLUSION This study reports on a protocol of cardiac and MR SAR to safely perform MR-guided LiTT in the setting of traditional pacemakers in patients who are not pacemaker dependent.
Evaluations of UltraiQ software for objective ultrasound image quality assessment using images from a commercial scanner
Long, Zaiyang , Tradup, Donald J., Stekel, Scott F. , Gorny, Krzysztof R. , Hangiandreou, Nicholas J.

Journal of Applied Clinical Medical Physics | January 16, 2018 | Volume: 19 | Issue: 2 | Pages: 298-304

10.1002/acm2.12255 Get It

AbstractWe evaluated a commercially available software package that uses B‐mode images to semi‐automatically measure quantitative metrics of ultrasound image quality, such as contrast response, depth of penetration (DOP), and spatial resolution (lateral, axial, and elevational). Since measurement of elevational resolution is not a part of the software package, we achieved it by acquiring phantom images with transducers tilted at 45 degrees relative to the phantom. Each measurement was assessed in terms of measurement stability, sensitivity, repeatability, and semi‐automated measurement success rate. All assessments were performed on a GE Logiq E9 ultrasound system with linear (9L or 11L), curved (C1‐5), and sector (S1‐5) transducers, using a CIRS model 040GSE phantom. In stability tests, the measurements of contrast, DOP, and spatial resolution remained within a ±10% variation threshold in 90%, 100%, and 69% of cases, respectively. In sensitivity tests, contrast, DOP, and spatial resolution measurements followed the expected behavior in 100%, 100%, and 72% of cases, respectively. In repeatability testing, intra‐ and inter‐individual coefficients of variations were equal to or less than 3.2%, 1.3%, and 4.4% for contrast, DOP, and spatial resolution (lateral and axial), respectively. The coefficients of variation corresponding to the elevational resolution test were all within 9.5%. Overall, in our assessment, the evaluated package performed well for objective and quantitative assessment of the above‐mentioned image qualities under well‐controlled acquisition conditions. We are finding it to be useful for various clinical ultrasound applications including performance comparison between scanners from different vendors.
Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator
Favazza, Christopher , Edmonson, Heidi A. , Shu, Yunhong , Felmlee, Joel P. , Watson, Robert E. , Gorny, Krzysztof R. , Favazza, Christopher P, Ma, Chi , Ma, Chi

Medical Physics | September 7, 2017 | Volume: 44 | Issue: 11 | Pages: 5749-5754

10.1002/mp.12567 Get It

PurposeTo assess risks of RF‐heating of a vagus nerve stimulator (VNS) during 1.5 T prostate MRI using body coil transmit and to compare these risks with those associated with MRI head exams using a transmit/receive head coil.MethodsSpatial distributions of radio‐frequency (RF) B1 fields generated by transmit/receive (T/R) body and head coils were empirically assessed along the long axis of a 1.5 T MRI scanner bore. Measurements were obtained along the center axis of the scanner and laterally offset by 15 cm (body coil) and 7 cm (head coil). RF‐field measurements were supplemented with direct measurements of RF‐heating of 15 cm long copper wires affixed to and submerged in the “neck” region of the gelled saline‐filled (sodium chloride and polyacrylic acid) “head‐and‐torso” phantom. Temperature elevations at the lead tips were measured using fiber‐optic thermometers with the phantom positioned at systematically increased distances from the scanner isocenter.ResultsB1 field measurements demonstrated greater than 10 dB reduction in RF power at distances beyond 28 cm and 24 cm from isocenter for body and head coil, respectively. Moreover, RF power from body coil transmit at distances greater than 32 cm from isocenter was found to be lower than from the RF power from head coil transmit measured at locations adjacent to the coil array at its opening. Correspondingly, maximum temperature elevations at the tips of the copper wires decreased with increasing distance from isocenter — from 7.4°C at 0 cm to no appreciable heating at locations beyond 40 cm.ConclusionsFor the particular scanner model evaluated in this study, positioning an implanted VNS farther than 32 cm from isocenter (configuration achievable for prostate exams) can reduce risks of RF‐heating resulting from the body coil transmit to those associated with using a T/R head coil.
Intramuscular fat infiltration evaluated by magnetic resonance imaging predicts the extensibility of the supraspinatus muscle
Giambini, Hugo , Gorny, Krzysztof R. , Widholm, Per , Karlsson, Anette , Leinhard, Olof Dahlqvist , Adkins, Mark C., Zhao, Chunfeng , An, Kai‐Nan, Hatta, Taku, Hatta, Taku , An, Kai‐Nan

Muscle & Nerve | April 25, 2017 | Volume: 57 | Issue: 1 | Pages: 129-135

10.1002/mus.25673 Get It

ABSTRACTIntroduction: Rotator cuff (RC) tears result in muscle atrophy and fat infiltration within the RC muscles. An estimation of muscle quality and deformation, or extensibility, is useful in selecting the most appropriate surgical procedure. We determined if noninvasive quantitative assessment of intramuscular fat using MRI could be used to predict extensibility of the supraspinatus muscle. Methods: Seventeen cadaveric shoulders were imaged to assess intramuscular fat infiltration. Extensibility and histological evaluations were then performed. Results: Quantitative fat infiltration positively correlated with histological findings and presented a positive correlation with muscle extensibility (r = 0.69; P = 0.002). Extensibility was not significantly different between shoulders graded with a higher fat content versus those with low fat when implementing qualitative methods. Discussion: A noninvasive prediction of whole‐muscle extensibility may directly guide pre‐operative planning to determine if the torn edge could efficiently cover the original footprint while aiding in postoperative evaluation of RC repair. Muscle Nerve 57: 129–135, 2018