Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator
Favazza, Christopher , Edmonson, Heidi A. , Shu, Yunhong , Felmlee, Joel P. , Watson, Robert E. , Gorny, Krzysztof R. , Favazza, Christopher P, Ma, Chi , Ma, Chi

Medical Physics | September 7, 2017 | Volume: 44 | Issue: 11 | Pages: 5749-5754

10.1002/mp.12567 Get It

PurposeTo assess risks of RF‐heating of a vagus nerve stimulator (VNS) during 1.5 T prostate MRI using body coil transmit and to compare these risks with those associated with MRI head exams using a transmit/receive head coil.MethodsSpatial distributions of radio‐frequency (RF) B1 fields generated by transmit/receive (T/R) body and head coils were empirically assessed along the long axis of a 1.5 T MRI scanner bore. Measurements were obtained along the center axis of the scanner and laterally offset by 15 cm (body coil) and 7 cm (head coil). RF‐field measurements were supplemented with direct measurements of RF‐heating of 15 cm long copper wires affixed to and submerged in the “neck” region of the gelled saline‐filled (sodium chloride and polyacrylic acid) “head‐and‐torso” phantom. Temperature elevations at the lead tips were measured using fiber‐optic thermometers with the phantom positioned at systematically increased distances from the scanner isocenter.ResultsB1 field measurements demonstrated greater than 10 dB reduction in RF power at distances beyond 28 cm and 24 cm from isocenter for body and head coil, respectively. Moreover, RF power from body coil transmit at distances greater than 32 cm from isocenter was found to be lower than from the RF power from head coil transmit measured at locations adjacent to the coil array at its opening. Correspondingly, maximum temperature elevations at the tips of the copper wires decreased with increasing distance from isocenter — from 7.4°C at 0 cm to no appreciable heating at locations beyond 40 cm.ConclusionsFor the particular scanner model evaluated in this study, positioning an implanted VNS farther than 32 cm from isocenter (configuration achievable for prostate exams) can reduce risks of RF‐heating resulting from the body coil transmit to those associated with using a T/R head coil.
FANCD2 and DNA Damage
Nepal, Manoj , Che, Raymond , Ma, Chi , Fei, Peiwen, Zhang, Jun

International Journal of Molecular Sciences | August 21, 2017 | Volume: 18 | Issue: 8 | Pages: 1804

10.3390/ijms18081804 Get It

Investigators have dedicated considerable effort to understanding the molecular basis underlying Fanconi Anemia (FA), a rare human genetic disease featuring an extremely high incidence of cancer and many congenital defects. Among those studies, FA group D2 protein (FANCD2) has emerged as the focal point of FA signaling and plays crucial roles in multiple aspects of cellular life, especially in the cellular responses to DNA damage. Here, we discuss the recent and relevant studies to provide an updated review on the roles of FANCD2 in the DNA damage response.
Evaluation of a projection-domain lung nodule insertion technique in thoracic computed tomography
Yu, Lifeng , Chen, Baiyu , Koo, Chi Wan , Takahashi, Edwin A. , Levin, David L. , Viers, Lyndsay D., Vincent-Sheldon, Stephanie, Ma, Chi , Kuzo, Ronald S. , Vincent-Sheldon, Stephanie A, Ma, Chi , Chen, Baiyu , Leng, Shuai , Leng, Shuai , Takahashi, Edwin A

Journal of Medical Imaging | March 31, 2017 | Volume: 4 | Issue: 1 | Pages: 013510

10.1117/1.jmi.4.1.013510 Get It