Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Citations 14
Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis
Background The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems. Method We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024. The primary outcome was a favorable outcome defined as a modified Rankin Scale (mRS) score of 0–2 at 90 days after the procedure. Data were analyzed using a random-effects model and heterogeneity was assessed using the I2 test and Q statistics. Results Five studies with a total of 1562 patients were analyzed. Of these, 68.4% were treated with biplane systems and 31.6% with single plane systems. Single plane angiography was associated with a significantly higher rate of favorable outcomes (OR 1.43; 95% CI 1.13 to 1.80; P<0.01). There were no significant differences in successful recanalization, periprocedural complications, procedure time, total fluoroscopy time, or contrast volume between the two systems. Conclusion While single plane angiography systems may offer slightly better outcomes in MT for AIS, both systems appear equally effective in most clinical and technical perspectives, suggesting that system selection may be more dependent on availability and procedural requirements rather than inherent superiority. Our findings may encourage clinicians to use single-plane angiography in settings where the biplane angiography suite availability is limited, but it should be noted that this observation may have been influenced by selection bias, particularly since the larger studies included in our meta-analysis did not observe this effect in adjusted analyses for potential confounder factors.
Optimizing the hemodynamics of hand injections in neuroangiography
Purpose Optimizing the preparation of a 10 ml syringe for manual injection of contrast media can help operators obtain easier and faster injections. This study aims to compare the flow rates of different contrast media injection methods. Methods Different contrast media solutions were compared: 100% contrast (10 ml contrast), mixed contrast solution (8:2 contrast/saline), and layered contrast below saline (“Parfait”) in different volumes. Contrast media were injected at room temperature (20°C) and after heating (37°C). Four operators injected 10 ml syringes filled with different mediums through 5-French angiographic catheters. The average flow rate was used to compare different contrast injection mediums. The Kruskal-Wallis test with post-hoc pairwise comparisons using Bonferroni correction or Mann-Whitney U-tests were employed depending on the type of comparison. Results Compared to the 100% contrast solution, every Parfait media and mixed contrast solution demonstrated significantly higher flow rates (p < 0.001). The 5 ml saline Parfait had the highest flow rate among the Parfait solutions. The 5 ml saline Parfait and the mixed solution had comparable flow rates (p = 0.237). Higher flow rates were observed upon heating both 100% contrast (p < 0.001) and mixed contrast solutions (p < 0.001) in comparison to their flow rates at room temperature. Conclusion This study demonstrates the capability of the Parfait and mixed contrast injections to achieve higher flow rates than the 100% contrast solutions. Heating the contrast media to 37°C also proves to be a viable strategy for further enhancing the flow rates for 100% and mixed contrast solutions.
Neck apposition is a key factor for aneurysm occlusion after Woven EndoBridge device embolization
Background Sealing of the aneurysm neck with a Woven EndoBridge (WEB) device is recommended for disrupting the blood flow inside the aneurysm. This study investigates the relationship between WEB neck apposition and aneurysm occlusion rates. Methods Aneurysms treated with a WEB from March 2017 to May 2022 at a single center were included. WEB neck apposition (poor/good) and WEB protrusion (yes/no) were evaluated on post-detachment high resolution cone beam CT images. Angiographic occlusion was assessed with the Bicêtre Occlusion Scale score (BOSS). Univariate and multivariable analysis tested the association between neck apposition and occlusion rates. Results The study included 159 aneurysms in 141 patients (mean age 55.8±11.2 years; 64.2% women). Good neck apposition and protrusion were noted in 123 (77.4%) and 30 (18.9%) cases, respectively. Inter-rater agreements were good for neck apposition (κ=0.75) and protrusion (κ=0.78). Complete and adequate occlusion was achieved in 104 (65%) and 130 (82%) cases, respectively (median follow-up 18 months). Good neck apposition was a strong independent predictor for both adequate (adjusted OR (aOR)=5.9, 95% CI 2.4 to 14.9; P<0.001) and complete occlusion (aOR=7.1, 95% CI 3.0 to 18.1; P<0.001). Protrusion was more frequent in the adequate occlusion group versus the aneurysm recurrence group without reaching statistical significance (P=0.06), but was associated with more thromboembolic complications (9/30 (30%) vs 12/129 (9%); P<0.01). WEB shape modification was significantly greater in poor apposition cases (P=0.03). Conclusions Achieving good neck apposition of the WEB strongly predicts aneurysm occlusion during follow-up. WEB protrusion should be minimized due to the increase in thromboembolic risk with limited impact on aneurysm occlusion.
Creating elastase aneurysms in rabbits: a video primer
The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field. Video 1 Surgical procedure of creating elastase-induced aneurysms in rabbits.