Background Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period. Methods and Results Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG‐gated 100 μs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present. Conclusions Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27‐day survival period using this balloon‐based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.
Percutaneous epicardial pacing using a novel transverse sinus device
AbstractBackgroundTransvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS).Methods and resultsWe designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof‐of‐concept and 5 additional acute canine experiments.The TS device recorded ventricular and atrial electrograms. The median amplitude of near‐field ventricular electrograms was 3.3 mA (IQR 2.0–4.3) and of near‐field atrial electrograms was 2.1 mA (IQR 1.3–2.2). The median ventricular threshold (N = 30) was 1.1 mA (IQR 0.7–3.1) at a median pulse width of 0.5 ms (IQR 0.5–0.5). The median atrial threshold (N = 10) was 2.4 mA (IQR 1.1–7.8) at a median pulse width of 0.5 ms (IQR 0.5–0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications.ConclusionsThis study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.
Ventricular Electrical Activation Delay and High-Frequency Electrocardiograms
Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
60 Utility of t wave amplitude as a non-invasive risk marker of sudden cardiac death in hypertrophic cardiomyopathy
Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.