Abstract Aims Inter-atrial shunt device therapy has shown mixed results in clinical trials, with clinical ‘non-responders’ typically showing features of more advanced heart failure. We aimed to analyse the haemodynamic and clinical response of a novel left atrial to coronary sinus (LA-CS) shunt device in patients with higher natriuretic peptide (NP) levels, a marker of disease severity. Methods and results An analysis population (n = 95) of patients from the ALT-FLOW early feasibility study with left ventricular ejection fraction >40% and 1-year follow up was analysed. The cohort was divided into low and high subgroups based on NP levels [b-type natriuretic peptide (BNP) and n-terminal pro BNP (NT-proBNP)]. The mean BNP and NT-proBNP levels for low versus high subgroups were 64.2 ± 34.3 versus 261 ± 103 and 322 ± 269 versus 2050 ± 1070 pg/mL, respectively. Patients in the high NP subgroup had evidence of more advanced disease including worse haemodynamic profiles, lower estimated glomerular filtration rate, and higher percentages of atrial fibrillation. The high NP subgroup experienced significant improvements in KCCQ-OSS and NYHA functional class (P < 0.0001 and P < 0.001, respectively) and to a similar magnitude compared with the low NP subgroup. Compared with pre-implant baseline, workload adjusted pulmonary artery wedge pressure at peak exercise declined in the high NP subgroup (PCWL, 164.1 vs. 96.0 mmHg/W/kg at 6 months, P < 0.003) as well as the low NP subgroup (115.9 vs. 65.9 mmHg/W/keg at 6 months, P < 0.001). Importantly, in both NP subgroups, there was preservation of cardiac index through 6 months as well as right ventricular structure (right ventricular diastolic dimension) and function (tricuspid annular systolic plane excursion) through 1 year. Conclusions The quality-of-life, haemodynamic, and functional class improvements along with stable right heart function seen in ALT-FLOW study of LA-CS shunt remain consistent in the subgroup with highest NP levels. This suggests that shunting location could influence outcomes in symptomatic heart failure patients.
Prognostic Factors Associated with Mortality in Cardiogenic Shock — A Systematic Review and Meta-Analysis
OBJECTIVES: The objectives of our systematic review and meta-analyses were to determine the diagnostic accuracy of central venous oxygen saturation (Scvo 2) in estimating mixed venous oxygen saturation (Svo 2) and cardiac index in critically ill patients. DATA SOURCES: A systematic search using MEDLINE, Cochrane Central Register of Controlled Trials, and Embase was completed on May 6, 2024. STUDY SELECTION: Studies of patients in the ICU for whom Scvo 2 and at least one reference standard test was performed (thermodilution and/or Svo 2) were included. DATA EXTRACTION: Individual patient data were used to calculate the pooled intraclass correlation coefficient (ICC) for Svo 2 and Spearman correlation for cardiac index. The Quality Assessment of Diagnostic Accuracy Studies-2 and Grading Recommendations Assessment, Development, and Evaluation tools were used for the risk of bias and certainty of evidence assessments. DATA SYNTHESIS: Of 3427 studies, a total of 18 studies with 1971 patients were identified. We meta-analyzed 16 studies (1335 patients) that used Svo 2 as a reference and three studies (166 patients) that used thermodilution as reference. The ICC for reference Svo 2 was 0.83 (95% CI, 0.75–0.89) with a mean difference of 2.98% toward Scvo 2. The Spearman rank correlation for reference cardiac index is 0.47 (95% CI, 0.46–0.48; p < 0.0001). CONCLUSIONS: There is moderate reliability for Scvo 2 in predicting Svo 2 in critical care patients with variability based on sampling site and presence of sepsis. There is limited evidence on the independent use of Scvo 2 in predicting cardiac index.
Cost-effectiveness of population screening for aortic stenosis
Abstract Aims Aortic stenosis (AS) is a progressive disease predominantly affecting elderly patients that carries significant morbidity and mortality without aortic valve replacement, the only proven treatment. Our objective was to determine the cost-effectiveness of AS screening using transthoracic echocardiography (TTE) in a geriatric population from the perspective of the publicly funded healthcare system in Canada. Methods and results Markov models estimating the cost-effectiveness ratio (ICER) for AS screening with a one-time TTE were developed. The model included diagnosed and undiagnosed AS health states, hospitalizations, transcatheter aortic valve replacement (TAVR), and post-TAVR health states. Primary analysis included screening at 70 and 80 years of age with intervention at symptom onset, with scenario analysis included for early intervention at the time of severe asymptomatic AS diagnosis. Monte Carlo simulation of 5000 replications was completed with a lifetime horizon and a 1.5% discount for costs and outcomes.Screening for AS at the age of 70 years was associated with an ICER of $156 722, and screening at 80 years of age was associated with an ICER of $28 005, suggesting that screening at 80 years of age is cost-effective when willingness-to-pay per QALY is $50 000. Scenario analysis with early intervention was not cost-effective, with an ICER of $142 157 at 70 years and $124 651 at 80 years. Conclusion Screening for AS at 80 years of age with a one-time TTE, in a Canadian population, improves quality of life and is cost-effective in a publicly funded healthcare system providing, TAVR is reserved for symptomatic patients.
Left Atrial to Coronary Sinus Shunting for Treatment of Heart Failure with Mildly Reduced or Preserved Ejection Fraction: The ALT FLOW Early Feasibility Study 1-Year Results
Abstract Aims Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. Methods and results Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was −5.7 (−8.6, −2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I–II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20–30) and 27 (22–32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. Conclusions In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.
Impact of hypoxic hepatitis in cardiogenic shock: a substudy of the DOREMI trial
AbstractWe present three cases of acute coronary obstruction postsurgical repair of type A aortic dissection, which were successfully treated with percutaneous coronary intervention. We describe a step‐by‐step approach to performing percutaneous coronary intervention in selective cases of coronary obstruction related to type A aortic dissection.
Cardiology researchers’ practices and perceived barriers to open science: an international survey
Objective Open science is a movement and set of practices to conduct research more transparently. Implementing open science will significantly improve public access and supports equity. It also has the potential to foster innovation and reduce duplication through data and materials sharing. Here, we survey an international group of researchers publishing in cardiovascular journals regarding their perceptions and practices related to open science. Methods We identified the top 100 ‘Cardiology and Cardiovascular Medicine’ subject category journals from the SCImago journal ranking platform. This is a publicly available portal that draws from Scopus. We then extracted the corresponding author’s name and email from all articles published in these journals between 1 March 2021 and 1 March 2022. Participants were sent a purpose-built survey about open science. The survey contained primarily multiple choice and scale-based questions for which we report count data and percentages. For the few text-based responses we conducted thematic content analysis. Results 198 participants responded to our survey. Participants had a mean response of 6.8 (N=197, SD=1.8) on a 9-point scale with endpoints, not at all familiar (1) and extremely familiar (9), when indicating how familiar they were with open science. When asked about where they obtained open science training, most participants indicated this was done on the job self-initiated while conducting research (n=103, 52%), or that they had no formal training with respect to open science (n=72, 36%). More than half of the participants indicated they would benefit from practical support from their institution on how to perform open science practices (N=106, 54%). A diversity of barriers to each of the open science practices presented to participants were acknowledged. Participants indicated that funding was the most essential incentive to adopt open science. Conclusions It is clear that policy alone will not lead to the effective implementation of open science. This survey serves as a baseline for the cardiovascular research community’s open science performance and perception and can be used to inform future interventions and monitoring.
The role of inotropes in cardiogenic shock: to help, to harm or do nothing at all?
Abstract Background Aortic pseudoaneurysms are complications that arise following cardiac surgery, thoracic trauma, infections, or inflammatory conditions. The mainstay treatment for aortic pseudoaneurysm is surgical management. Given significant morbidity and mortality related to thoracotomy, high-risk patients are not considered for cardiac surgery. Novel percutaneous repair using a variety of devices are being explored, especially in those with prohibitive risk for cardiac surgery. Case summary This case describes the use of an Amplatzer atrial septal defect (ASD) occluder device to manage an aortic pseudoaneurysm in a 69-year-old male who had previously undergone coronary artery bypass graft surgery and pericardial drainage for purulent pericarditis. Following successful implant, there were no complications seen after 2 years of follow-up. Discussion Percutaneous closure of a mycotic pseudoaneurysm with an Amplatzer ASD occluder device can be a safe and efficacious treatment option, especially in patients with prohibitive surgical risk.