AbstractModulating the nerve's local microenvironment using exosomes is proposed to enhance nerve regeneration. This study aimed to determine the optimal dose of purified exosome product (PEP) required to exert maximal neurite extension. An in vitro dorsal root ganglion (DRG) neurite outgrowth assay was used to evaluate the effect of treatment with (i) 5% PEP, (ii) 10% PEP, (iii) 15% PEP, or (iv) 20% PEP on neurite extension (N = 9/group), compared to untreated controls. After 72 h, neurite extension was measured to quantify nerve regeneration. Live cell imaging was used to visualize neurite outgrowth during incubation. Treatment with 5% PEP resulted in the longest neurite extension and was superior to the untreated DRG (p = 0.003). Treatment with 10% PEP, 15% PEP, and 20% PEP was found to be comparable to controls (p = 0.12, p = 0.06, and p = 0.41, respectively) and each other. Live cell imaging suggested that PEP migrated towards the DRG neural regeneration site, compared to the persistent homogenous distribution of PEP in culture media alone. 5% PEP was found to be the optimal concentration for nerve regeneration based on this in vitro dose–response analysis.
Case: A 62-year-old man presented with a 10-year history of isolated melanonychia striata of his dominant thumb. Surgical biopsy ruled out subungual melanoma but revealed foreign plant material causing chronic infectious melanonychia from multiple pathogens, including Pseudomonas aeruginosa , Escherichia coli , and Candida spp. After removal of the nail plate and thorough debridement, the melanonychial streak resolved completely at 12 months of follow-up. Conclusion: Bacterial infection is a rarely reported cause of melanonychia, and in addition to surgical pathologic specimens, intraoperative fungal and bacterial cultures should always be obtained for accurate diagnosis of melanonychia striata.
Utility of preoperative MRI for assessing proximal fragment vascularity in scaphoid nonunion
AimsThe benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid.MethodsA retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy.ResultsPreoperative MRI identified 55 proximal scaphoid fragments with ischaemia and 47 with vascularized proximal fragments. After the proximal fragment was prepared, the tourniquet was deflated and assessed for bleeding; 63 proximal fragments had no bleeding and 39 demonstrated bleeding. MRI was not reliable or accurate in the assessment of proximal fragment vascularity when compared with intraoperative assessment of bleeding. No patient or MRI factors were identified to have a statistical impact on MRI accuracy.ConclusionCurrent preoperative MRI protocols and diagnostic criteria do not provide a high degree of correlation with observed intraoperative assessment of proximal fragment bleeding. While preoperative MRI may assist in surgical planning, intraoperative assessment remains the best means for assessing proximal fragment vascularity in scaphoid nonunion. Future efforts should focus on the development of objective measures of osseous blood flow that may be performed intraoperatively.Cite this article: Bone Joint J 2023;105-B(6):657–662.
Muscle activation for targeted elbow force production following surgical reconstruction in adults with brachial plexus injury
AbstractNerve transfer or grafting surgery to restore elbow flexion in peripheral nerve injuries has been an effective technique, but alters neuromuscular control compared with healthy individuals. This study compared neuromuscular control in the elbow flexors of 11 unimpaired control subjects and 11 adult patients with traumatic brachial plexus injury who underwent a nerve transfer or grafting procedure to the biceps motor branch to restore elbow flexion. The subjects performed a series of trials to generate a specific percentage of their maximum elbow torque. Each trial had an increasing and decreasing stairstep torque pattern that the subjects were asked to match. The amount of time that the subject's elbow torque was maintained within 5% of the target torque was calculated. The hypothesis was that there was a significant difference in the neuromuscular control between the two groups during elbow isometric torque generation. A secondary hypothesis was that a relationship existed between the neuromuscular control and the torque level for each group. The results demonstrated that neuromuscular control was different between the groups and there were significant differences in how torque levels are generated. The control group more easily modulated their myoelectric activation and achieved greater neuromuscular control variability with varying torque demand. The nerve transfer or grafting group could not modulate their myoelectric activation with changing torque demands. Further studies focusing on the improvement of neuromuscular control are needed to optimize functional outcomes in nerve injury patients.
» Iatrogenic nerve injuries may occur after any intervention of the upper extremity. » Causes of iatrogenic nerve lesions include direct sharp or thermal injury, retraction, compression from implants or compartment syndrome, injection, patient positioning, radiation, and cast/splint application, among others. » Optimal treatment of iatrogenic peripheral nerve lesions relies on early and accurate diagnosis. » Advanced imaging modalities (e.g., ultrasound and magnetic resonance imaging) and electrodiagnostic studies aid and assist in preoperative planning. » Optimal treatment of iatrogenic injuries is situation-dependent and depends on the feasibility of direct repair, grafting, and functional transfers.
Reconstruction of Triangular Fibrocartilage Complex Avulsions (Palmar 1C) with Associated Lunotriquetral and Dorsal Capsule Injury
Case: A 34-year-old farmer and railroad worker injured his left wrist when working at a railroad. The resulting dorsal-ulnar wrist blow caused disabling pain. Splits and 2 subsequent surgeries failed, including an arthroscopic triangular fibrocartilage complex (TFCC) debridement and thermal ablation. Subsequently, magnetic resonance imaging documented a rare Palmer type 1C distal TFCC avulsion. Function was restored and return to farming permitted by reconstruction of the ulnotriquetral (UT) ligament using an extensor carpi ulnaris (ECU) slip. Conclusion: Chronic Palmer type 1C TFCC injuries can be successfully treated with ECU reconstruction of the UT ligament.
Passive wrist deviation to increase the ultrasound identified procedural safe zone in carpal tunnel syndrome: A retrospective cohort study
AbstractIntroductionCarpal tunnel syndrome (CTS) is the most common peripheral nerve entrapment syndrome. Although prior studies have explored the anatomic changes of the median nerve and carpal arch with different wrist deviations and positionings, the change in safe zone distance between the median nerve and ulnar artery with ulnar or radial wrist deviations has not been adequately investigated.ObjectiveTo identify the optimal wrist positioning that increases the safe zone distance between the median nerve and ulnar artery using ultrasound in patients with CTS.DesignRetrospective cohort study.SettingQuaternary medical center multidisciplinary outpatient hand clinic.ParticipantsTwenty five patients (41 wrists) with clinical CTS who received an electrodiagnostic study (EDX) to evaluate CTS within 1 year prior to enrollment.InterventionsUltrasound‐identified safe zone distance measurements were obtained in each patient between the ulnar aspect of the median nerve and the radial aspect of the ulnar artery with the wrist in neutral radial‐ulnar deviation as well as in passive ulnar and radial deviation.Main Outcome MeasureThe ultrasound‐identified safe zone distance with the wrist in each of the three positions.ResultsThe interstructural safe zone distance was significantly greater when measured in the ulnarly deviated position (1.08 cm) compared with either the neutral (0.61cm, p < .001) or radially deviated positions (0.52 cm, p < .001). Interstructural safe zone distance did not differ between those with normal, mild, moderate, or severe classifications of pathology, or between dominant and nondominant limbs.ConclusionThis study demonstrates that the ultrasound‐measured interstructural safe zone distance was significantly greater in the ulnarly deviated position than in either the neutral position or radially deviated position. These findings may lead to improvement in the safety of ultrasound‐guided injections.
A multidisciplinary approach to the management of brachial plexus injuries: experience from the Mayo Clinic over 100 years
A multidisciplinary brachial plexus clinic has been a relatively new concept, offering different surgical speciality perspectives on the treatment of brachial plexus injuries. The resulting collaborative effort has proven to be greater than the sum of its parts. In this review, the history, philosophy of care, development/implementation and impact of a creation of a multidisciplinary brachial plexus team at the Mayo Clinic are detailed.
The Role of Amputation and Myoelectric Prosthetic Fitting in Patients with Traumatic Brachial Plexus Injuries
Background: A cohort of patients with traumatic brachial plexus injuries (BPIs) underwent elective amputation following unsuccessful surgical reconstruction or delayed presentation. The results of amputation with and without a myoelectric prosthesis (MEP) using nonintuitive controls were compared. We sought to determine the benefits of amputation, and whether fitting with an MEP was feasible and functional. Methods: We conducted a retrospective review of patients with BPI who underwent elective upper-extremity amputation at a single institution. Medical records were reviewed for demographics, injury and reconstruction details, amputation characteristics, outcomes, and complications. Prosthesis use and MEP function were assessed. The minimum follow-up for clinical outcomes was 12 months. Results: Thirty-two patients with BPI and an average follow-up of 53 months underwent elective amputation between June 2000 and June 2020. Among the cases were 18 transhumeral amputations, 12 transradial amputations, and 2 wrist disarticulations. There were 29 pan-plexus injuries, 1 partial C5-sparing pan-plexus injury, 1 lower-trunk with lateral cord injury, and 1 lower-trunk injury. Amputation occurred, on average, at 48.9 months following BPI and 36.5 months following final reconstruction. Ten patients were fitted for an MEP with electromyographic signal control from muscles not normally associated with the intended function (nonintuitive control). Average visual analog scale pain scores decreased post-amputation: from 4.8 pre-amputation to 3.3 for the MEP group and from 5.4 to 4.4 for the non-MEP group. Average scores on the Disabilities of the Arm, Shoulder and Hand questionnaire decreased post-amputation, but not significantly: from 35 to 30 for the MEP group and from 43 to 40 for the non-MEP group. Patients were more likely to be employed following amputation than they were before amputation. No patient expressed regret about undergoing amputation. All patients in the MEP group reported regular use of their prosthesis compared with 29% of patients with a traditional prosthesis. All patients in the MEP group demonstrated functional terminal grasp/release that they considered useful. Conclusions: Amputation is an effective treatment for select patients with BPI for whom surgical reconstruction is unsuccessful. Patients who underwent amputation reported decreased mechanical pain, increased employment rates, and a high rate of satisfaction following surgery. In amputees with sufficient nonintuitive electromyographic signals, MEPs allow for terminal grasp/release and are associated with high rates of prosthesis use. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Role of adipose tissue grafting and adipose-derived stem cells in peripheral nerve surgery
The application of autologous fat grafting in reconstructive surgery is commonly used to improve functional form. This review aims to provide an overview of the scientific evidence on the biology of adipose tissue, the role of adipose-derived stem cells, and the indications of adipose tissue grafting in peripheral nerve surgery. Adipose tissue is easily accessible through the lower abdomen and inner thighs. Non-vascularized adipose tissue grafting does not support oxidative and ischemic stress, resulting in variable survival of adipocytes within the first 24 hours. Enrichment of adipose tissue with a stromal vascular fraction is purported to increase the number of adipose-derived stem cells and is postulated to augment the long-term stability of adipose tissue grafts. Basic science nerve research suggests an increase in nerve regeneration and nerve revascularization, and a decrease in nerve fibrosis after the addition of adipose-derived stem cells or adipose tissue. In clinical studies, the use of autologous lipofilling is mostly applied to secondary carpal tunnel release revisions with promising results. Since the use of adipose-derived stem cells in peripheral nerve reconstruction is relatively new, more studies are needed to explore safety and long-term effects on peripheral nerve regeneration. The Food and Drug Administration stipulates that adipose-derived stem cell transplantation should be minimally manipulated, enzyme-free, and used in the same surgical procedure, e.g. adipose tissue grafts that contain native adipose-derived stem cells or stromal vascular fraction. Future research may be shifted towards the use of tissue-engineered adipose tissue to create a supportive microenvironment for autologous graft survival. Shelf-ready alternatives could be enhanced with adipose-derived stem cells or growth factors and eliminate the need for adipose tissue harvest.