Back to Authors

Miller, Emily

0000-0003-2744-9134

Mayo Clinic

Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA.

Citations 2

Design and Development of a Powered Myoelectric Elbow Orthosis for Neuromuscular Injuries
Vignola, Claudio, Bhat, Sandesh G. , Hollander, Kevin W., Kane, Paul H., Miller, Emily J. , Martin, W. Brandon , Shin, Alexander Y. , Sugar, Thomas G. , Kane, Paul, Miller, Emily , Kaufman, Kenton R , Shin, Alexander Y , Bhat, Sandesh G , Kaufman, Kenton R.

Military Medicine | April 3, 2024 | Volume: 189 | Issue: Supplement_3 | Pages: 585-591

10.1093/milmed/usae196 Get It

ABSTRACT Introduction Recovering from neuromuscular injuries or conditions can be a challenging journey that involves complex surgeries and extensive physical rehabilitation. During this process, individuals often rely on orthotic devices to support and enable movement of the affected limb. However, users have criticized current commercially available powered orthotic devices for their bulky and heavy design. To address these limitations, we developed a novel powered myoelectric elbow orthosis. Materials and Methods The orthosis incorporates 3 mechanisms: a solenoid brake, a Bowden cable-powered constant torque elbow mechanism, and an extension limiter. The device controller and battery are in a backpack to reduce the weight on the affected arm. We performed extensive calculations and testing to ensure that the orthosis could withstand at least 15 Nm of elbow torque. We developed a custom software effectively control the orthosis, enhancing its usability and functionality. A certified orthotist fitted a subject who had undergone a gracilis free functioning muscle transfer surgery with the device. We studied the subject under Mayo clinic IRB no. 20-006849 and obtained objective measurements to assess the orthosis’s impact on upper extremity functionality during daily activities. Results The results are promising since the orthosis significantly improved elbow flexion range of motion by 40° and reduced compensatory movements at the shoulder (humerothoracic joint) by 50°. Additionally, the subject was able to perform tasks which were not possible before, such as carrying a basket with weights, highlighting the enhanced functionality provided by the orthosis. Conclusion In brief, by addressing the limitations of existing devices, this novel powered myoelectric elbow orthosis offers individuals with neuromuscular injuries/conditions improved quality of life. Further research will expand the patient population and control mechanisms.
Muscle activation for targeted elbow force production following surgical reconstruction in adults with brachial plexus injury
Bhat, Sandesh G. , Miller, Emily J. , Shin, Alexander Y. , Kaufman, Kenton R , Shin, Alexander Y , Miller, Emily , Bhat, Sandesh G , Kaufman, Kenton R.

Journal of Orthopaedic Research | February 23, 2023 | Volume: 41 | Issue: 9 | Pages: 2032-2039

10.1002/jor.25534 Get It

AbstractNerve transfer or grafting surgery to restore elbow flexion in peripheral nerve injuries has been an effective technique, but alters neuromuscular control compared with healthy individuals. This study compared neuromuscular control in the elbow flexors of 11 unimpaired control subjects and 11 adult patients with traumatic brachial plexus injury who underwent a nerve transfer or grafting procedure to the biceps motor branch to restore elbow flexion. The subjects performed a series of trials to generate a specific percentage of their maximum elbow torque. Each trial had an increasing and decreasing stairstep torque pattern that the subjects were asked to match. The amount of time that the subject's elbow torque was maintained within 5% of the target torque was calculated. The hypothesis was that there was a significant difference in the neuromuscular control between the two groups during elbow isometric torque generation. A secondary hypothesis was that a relationship existed between the neuromuscular control and the torque level for each group. The results demonstrated that neuromuscular control was different between the groups and there were significant differences in how torque levels are generated. The control group more easily modulated their myoelectric activation and achieved greater neuromuscular control variability with varying torque demand. The nerve transfer or grafting group could not modulate their myoelectric activation with changing torque demands. Further studies focusing on the improvement of neuromuscular control are needed to optimize functional outcomes in nerve injury patients.