Back to Authors

Williams, Lance A

0000-0002-2453-255X

Mayo Clinic

Mayo Clinic in Arizona

Citations 6

Legendary Case of Factitious Disorder Presenting as ‘Sickle Cell Disease’ Creates Challenges for All Medical Specialties
Iverson, Olivia , Kinard, Theresa N. , Williams, Lance A , Winters, Jeffrey L.

Journal of Clinical Apheresis | January 15, 2025 | Volume: 40 | Issue: 1 | Pages: No page available

10.1002/jca.70005 Get It

Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters
Su, Leon , Secor, Daniel T. , McGary, Alyssa , Nguyen, Michelle , Kinard, Theresa N. , Adamski, Jill , Stoker, Alex D., Frasco, Peter E. , Su, Leon L , McGary, Alyssa K, Nguyen, Michelle C , Jadlowiec, Caroline , Adamksi, Jill , Stoker, Alex D , Jadlowiec, Caroline C. , Williams, Lance A

Liver Transplantation | October 11, 2024 | Volume: 31 | Issue: 4 | Pages: 464-475

10.1097/lvt.0000000000000507 Get It

The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.
The first reported use of red blood cell exchange to treat hemoglobin Evans with secondary methemoglobinemia
Adamski, Jill , Kinard, Theresa N. , Ertz-Archambault, Natalie , Lu, Qun , Gray, Kristin , Su, Leon , Padrnos, Leslie , Williams, Lance A , Herrick, Jennifer L.

Journal of Clinical Apheresis | September 4, 2023 | Volume: 38 | Issue: 6 | Pages: 755-759

10.1002/jca.22086 Get It

Abstract This manuscript describes a novel approach for treating patients with long‐term sequelae from hemoglobin Evans (Hb Evans). After instituting conservative therapies for approximately 2 years, our patient's symptoms continually worsened. Therefore, we performed red blood cell exchange (RBCx) to reduce his Hb Evans percentage and his co‐existing elevation of methemoglobin. Our assumptions of clinical benefit were based on our collective experience performing RBCx for patients with sickle cell disease. After the first exchange, pre‐ and post‐laboratory results supported our approach and the patient experienced marked improvement in his clinical signs and symptoms. This report provides preliminary proof of principle for the use of RBCx to treat Hb Evans and other non‐Hb S hemoglobinopathies.
Optimizing factor VIII dosing in obese individuals with haemophilia A
Godby, Richard , Raju, Dheeraj , Massicano, Felipe, Black, Briley S., Dorn, David, Godby, Richard Curtis , Williams, Lance A , Marques, Marisa B.

Blood Coagulation & Fibrinolysis | July 21, 2021 | Volume: 32 | Issue: 7 | Pages: 528-530

10.1097/mbc.0000000000001067 Get It

Exclusive use of PowerFlow ports may not be appropriate for all patients
Boshell, Michael N., Adamski, Jill , Pham, Huy P. , Guillory, Bryan, Sikora, James , Lisby, Stephanie, Lovingood, Ashley, Zheng, Xuemei , Williams, Lance A , Pham, Huy P , Marques, Marisa B.

Journal of Clinical Apheresis | September 18, 2019 | Volume: 35 | Issue: 1 | Pages: 66-68

10.1002/jca.21749 Get It

New subcutaneous PowerFlow port results in cost and time‐savings in a busy outpatient apheresis clinic
Arnesen, Christine, Gunn, Christina, Boshell, Michael N., Pham, Huy P. , Guillory, Bryan, Adamski, Jill , Williams, Lance A , Pham, Huy P , Marques, Marisa B.

Journal of Clinical Apheresis | December 13, 2018 | Volume: 34 | Issue: 4 | Pages: 482-486

10.1002/jca.21678 Get It

AbstractMany vascular access options, such as subcutaneous ports, are currently on the market for use in both medication infusion and for procedures, such as therapeutic plasma exchange and extracorporeal photopheresis. We compared the cost and time necessary to complete apheresis procedures using either Angiodynamic's Vortex or Bard's PowerFlow subcutaneous ports by reviewing our experience on two patients undergoing long‐term apheresis treatments with at least 10 procedures with each type of port. We analyzed the cost of needles and thrombolytic therapy, staff time, overall procedure length, and the total time the patient was in the apheresis unit. We also compared flow rates and alarm rates between the two ports. In this small pilot study, use of the PowerFlow port resulted in significant cost and time savings, with mixed results for flow rates. Our results need to be confirmed in a larger patient population prior to recommending wide implementation of Bard's PowerFlow port.