Back to Authors

Nguyen, Michelle

https://orcid.org/0000-0003-4827-6367

Mayo Clinic

Mayo Clinic

Citations 13

Liver transplantation: embracing the future with machine perfusion
Wiederkehr, Henrique de Aguiar , Nguyen, Michelle , Moss, Adyr A. , Mathur, Amit K. , Nunez-Nateras, Rafael, Wiederkehr, Júlio César , Coelho, Júlio Cézar Uili , Nguyen, Michelle C , Moss, Adyr , Mathur, Amit , Núñez-Nateras, Rafael

ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo) | July 27, 2026 | Volume: 39 | Issue: No issue available | Pages: No page available

10.1590/0102-672020260000017e1946 Get It

ABSTRACT Despite the annual increase in liver transplants, a persistent disparity between suitable donors and recipients continues to challenge the transplant community. The introduction of machine perfusion emerged as a novel approach to organ preservation. This technique, which utilizes extended criteria donor grafts, is expected to reduce rejection rates and expand the donor pool. Its principle, like that of any ex vivo machine perfusion, is based on the continuous supply of nutrients and oxygen to maintain cellular metabolism while interrupting anaerobic processes. This helps prevent conditions such as ischemia-reperfusion injury, early graft dysfunction, and ischemic cholangiopathy, which can lead to graft loss and the need for retransplantation. There are two main modes of ex vivo machine perfusion: hypothermic and normothermic, differentiated by the operating temperature. Utilizing ex situ perfusion machines presents a promising opportunity to increase liver graft usage and reduce waitlist times. However, it is crucial to evaluate how much this technology would raise the overall cost of transplants. In Brazil, implementing a machine perfusion program may encounter unique challenges not seen in other countries. These challenges include limited access to the healthcare system for high-risk liver transplant candidates, long waiting lists, inadequate support for organ donors, reliance solely on deceased brain-dead donors, since donation after cardiac death is not ethically accepted, and geographical barriers.
Overall Outcomes of Liver Transplantation Using Upfront Normothermic Machine Perfusion: A Real-World Single-Center Experience
Nguyen, Michelle , Ohara, Stephanie Y., Barnhill, Michele , Madisetty, Alekhya, Zhang, Nan, Wiederkehr, Henrique, Jayasekera, Channa R. , Aqel, Bashar A., Reddy, K.R., Mathur, Amit K., Nguyen, Michelle C , Reddy, K. Sudhakar, Ohara, Stephanie , Barnhill, Michele , Wiederkehr, Henrique de Aguiar , Aqel, Bashar A. , Mathur, Amit K.

Annals of Surgery | July 22, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/sla.0000000000007155 Get It

Objective: To determine whether normothermic machine perfusion (NMP) mitigates the historical survival disadvantage of donation after circulatory death (DCD) liver transplantation compared with donation after brain death (DBD) livers. Summary Background Data: NMP has improved outcomes in DCD LT compared with static cold storage (SCS), but whether it eliminates the historical disparity relative to DBD transplantation remains uncertain. Methods: We performed a retrospective cohort study of adult LT at a high-volume US center between 2019 and 2024. Outcomes of DCD-NMP grafts were compared with DCD-SCS, DBD-SCS, and DBD-NMP grafts. Primary outcomes were 1-year graft and patient survival. Secondary outcomes included early allograft dysfunction (EAD), hepatic artery thrombosis (HAT), primary nonfunction (PNF), biliary anastomotic strictures (BAS), and ischemic cholangiopathy (IC). Results: Among 1338 liver transplants (DBD-SCS n=527; DBD-NMP n=142; DCD-SCS n=255; DCD-NMP n=414), DCD-NMP grafts had a significantly higher donor risk profile ( P <0.001) yet demonstrated survival comparable to DBD transplantation. One-year graft survival was 94% for DCD-NMP versus 93% for DBD grafts and 86% for DCD-SCS, and 1-year patient survival was 98% for DCD-NMP versus 94% to 95% for DBD grafts and 93% for DCD-SCS. In adjusted models, DCD-SCS was associated with increased hazards of graft loss (adjusted hazard ratio: 2.48; P <0.001) and death (adjusted hazard ratio: 2.39; P =0.004), whereas DBD groups did not differ from DCD-NMP. Incidence of EAD was lower with DCD-NMP (21.7%) than DCD-SCS (50.2%) and similar to DBD grafts (21.1%–26.4%); HAT and PNF were rare (≤1.3%). At 1 year, BAS occurred in 36% of DCD grafts versus 17% to 23% of DBD grafts. IC occurred in 7.7% of DCD-NMP compared with 22% of DCD-SCS and ≤1.5% of DBD grafts. Retransplantation due to IC was infrequent overall (1.3%), but more common in DCD-SCS (4.7%) than DCD-NMP (1.0%) and DBD grafts (≤0.4%). Conclusions: NMP enables safe utilization of DCD liver allografts and achieves graft and patient survival comparable to DBD LT, mitigating the historical disadvantage of DCD grafts. These findings support routine integration of NMP into clinical practice and efforts to standardize its implementation.
Preemptive anticraving therapies reduce alcohol relapse after liver transplantation in high-risk individuals
Jayasekera, Channa R. , Engster, Pedro Henrique de Borba , Terwilliger, Emma C. , Sinha, Shirshendu , Lankton, LPC Julie, Nguyen, Michelle C, Chascsa, David M. , Barnhill, Michele , Lizaola-Mayo, Blanca, Votruba, Cassandra, Dickson, Rolland C. , Lizaola‐Mayo, Blanca , Nguyen, Michelle , de Borba Engster, Pedro Henrique, Julie Lankton, Lpc, Nguyen, Michelle C , Chascsa, David M , Lizaola-Mayo, Blanca , Barnhill, Michele , Votruba, Cassandra

Liver Transplantation | May 12, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/lvt.0000000000000902 Get It

Rapid Point-of-Care Inflammatory Cytokine Monitoring during Normothermic Liver Perfusion via a Multiplexed Paper-Based Vertical Flow Assay
Tang, Rui-Chian , Palanisamy, Barath , Ghosh, Rajesh , Lee, M.H.F. , Han, Gyeo‐Re , Shen, Xiling, Jucaud, Vadim , Ozcan, Aydogan, Carlo, Dino Di, Ozcan, Aydogan , Di Carlo, Dino , Jucaud, Vadim , Nguyen, Michelle , Shen, Xiling

ACS Sensors | January 8, 2026 | Volume: 11 | Issue: 1 | Pages: 43-54

10.1021/acssensors.5c01902 Get It

Overcoming hepatic artery variations: Arterial reconstruction strategies to expand normothermic machine perfusion in liver transplantation
Ohara, Stephanie, Li, Xingjie , Ruch, Brianna , Nunez-Nateras, Raphael, Cosentino, Christopher P., Mirie, Kayla R., Hewitt, Winston R. , Harbell, Jack W. , Singer, Andrew L., Moss, Adyr A. , Reddy, Kunam S. , Mathur, Amit K. , Nunez-Nateras, Raphael, Zhang, Nan , Katariya, Nitin , Jadlowiec, Caroline C. , Nguyen, Michelle

Liver Transplantation | September 26, 2025 | Volume: 32 | Issue: 6 | Pages: 812-822

10.1097/lvt.0000000000000741 Get It

Normothermic machine perfusion (NMP) enables preservation and functional assessment of liver allografts, improving outcomes, particularly in marginal organs. However, the TransMedics Organ Care System (OCS) permits only single hepatic artery (HA) cannulation, limiting its use in grafts with variant arterial anatomy. Arterial reconstruction before NMP may overcome this limitation and expand the pool of grafts eligible for perfusion. We conducted a retrospective single-center cohort study of adult liver transplants utilizing OCS from January 2022 to September 2024. Allografts with variant hepatic artery anatomy requiring arterial reconstruction before NMP initiation were identified. Postoperative outcomes, including vascular and biliary complications, were compared between reconstructed and non-reconstructed grafts. Among 541 OCS-preserved grafts, 74 (13.7%) underwent arterial reconstruction. Compared with non-reconstructed grafts, reconstructed grafts had longer cross-clamp to cannulation time (2.8 vs. 2.4 h, p <0.001), but similar rates of early allograft dysfunction (23.0% vs. 20.8%, p =0.65), ischemic cholangiopathy (4.1% vs. 4.1%, p =1.00), and primary nonfunction (0.0% vs. 0.4%, p =1.00). Early (2.7% vs. 0.2%, p =0.05) and late hepatic artery thrombosis (HAT) (4.1% vs. 2.1%, p =0.40) were infrequent and not significantly different between non-reconstructed and reconstructed groups, respectively. Hepatic artery stenosis occurred more often in reconstructed grafts (12.2% vs. 4.1%, p =0.008), though most cases were managed with interventional radiology or surgical revision. Only one reconstructed graft required retransplantation due to vascular complications. Arterial reconstruction before NMP is safe and feasible, enabling successful perfusion and transplantation of liver allografts with variant HA anatomy. These findings support the broader application of NMP in anatomically complex donor livers.
Survey of Early Practices and Perceptions of Liver Machine Perfusion Among US Liver Transplant Surgeons
Nguyen, Michelle , Li, Xingjie , Ohara, Stephanie, Motamed, Mehrdad, Moss, Adyr A. , Reddy, Kunam S. , Mathur, Amit K. , Nguyen, Michelle C , Zhang, Chi , Motamed, Mehrdad, Jadlowiec, Caroline C.

Transplantation Direct | June 27, 2025 | Volume: 11 | Issue: 7 | Pages: e1841

10.1097/txd.0000000000001841 Get It

Background. Ex vivo machine perfusion (MP) has transformed organ preservation, offering significant benefits in liver transplantation (LT), particularly with high-risk donor grafts. However, adoption in the United States has been limited. We aimed to examine early adoption trends, surgeon perceptions, and barriers to implementing MP in the United States after Food and Drug Administration approval of MP platforms. Methods. A 23-question electronic survey was distributed to members of the American Society of Transplant Surgeons between October and November 2022, capturing attitudes and practices related to MP adoption. Responses from 96 surgeons representing 77 LT centers across 11 Organ Procurement and Transplantation Network regions were analyzed. Results. Forty-four respondents (48%) reported having an MP program at their institution. Adoption of MP was significantly more common in high-volume centers and those performing ≥20 donation after circulatory death (DCD) transplants annually (P < 0.001). MP utilization received strong support, with 88% endorsing its use for DCD liver allografts and 82% for donation after brain death allografts. Respondents cited MP’s ability to reduce ischemic cholangiopathy, enable graft repair, and facilitate viability assessment as key benefits. Normothermic MP was preferred for high-risk donor profiles, including DCD grafts, older donors, and steatotic livers, and was associated with an increased willingness to accept medically complex grafts compared with static cold storage. Barriers to MP utilization included program costs, personnel demands, and logistical complexities. Centers with higher proportions of privately insured patients were more likely to adopt MP. Despite these challenges, 84% of respondents expressed interest in future MP adoption. Conclusions. MP enhances graft utilization and outcomes, particularly for complex and high-risk donor livers, but widespread US adoption requires addressing financial and logistical barriers. Future efforts should focus on refining cost-effectiveness analyses, collaboration with organ procurement organizations and device companies, and developing standardized training to optimize MP integration and maximize its clinical impact on LT.
Normothermic Machine Perfusion Improves Outcomes for Donation After Cardiac Death Allografts With Extended Donor Warm Ischemia Time
Li, Xingjie , Ohara, Stephanie , Reddy, Kunam S. , Mathur, Amit K. , Nguyen, Michelle , Ohara, Stephanie Y , Jadlowiec, Caroline , Mathur, Amit , Nguyen, Michelle C , Chang, Yu‐Hui , Jadlowiec, Caroline C.

Clinical Transplantation | March 16, 2025 | Volume: 39 | Issue: 3 | Pages: No page available

10.1111/ctr.70133 Get It

ABSTRACT Introduction Donation after circulatory death (DCD) allografts are underutilized in liver transplantation (LT) due to increased risk of complications. These risks stem from ischemic injury sustained during the total donor warm ischemia time (tDWIT), historically limited to 30 min. Normothermic machine perfusion (NMP) can mitigate these risks and facilitate LT of DCD grafts with extended tDWIT. We aimed to compare outcomes of DCD allografts with extended tDWIT preserved on NMP versus static cold storage (SCS). Methods This single‐center study included adult DCD LT with tDWIT ≥ 30 from 2019 to 2023. Outcomes of NMP and SCS were compared including EAD, IC, graft survival, and patient survival. Results Among 68 DCD LT with tDWIT ≥ 30, 64.7% ( n = 44) were preserved with NMP and 35.3% ( n = 24) with SCS. No differences in donor or recipient demographics were observed. The median tDWIT was 33 min for NMP and 30.5 min for SCS ( p < 0.01). Despite longer tDWIT, the NMP group had lower rates of EAD (4.5% vs. 66.7%, p < 0.01) and IC (2.3% vs. 29.2%, p < 0.01). One‐year graft survival was higher in NMP ( p < 0.01), and 1‐year patient survival was comparable between groups ( p = 0.18). Conclusion NMP challenges traditional tDWIT constraints and can increase the pool of viable DCD allografts for transplantation.
Incisional Hernia Risk Reduction for Living Kidney Donors: Kidney Extraction Site Matters
Punukollu, Rachana , Ohara, Stephanie , Alexandru, Nica, Cosentino, Christopher P., Frasco, Peter E. , Andrews, Paul E. , Nica, Alexandru , Briggs, Logan G , Cosentino, Christopher, Frasco, Peter, Andrews, Paul , Mao, Shennen, Punukollu, Rachana , Arias, Sandra, Briggs, Logan , Nguyen, Michelle , Mao, Shennen A. , Heimbach, Julie K. , Jadlowiec, Caroline C.

Journal of the American College of Surgeons | February 13, 2025 | Volume: 241 | Issue: 2 | Pages: 195-202

10.1097/xcs.0000000000001356 Get It

BACKGROUND: Although most transplant centers preferentially offer minimally invasive approaches to donor nephrectomies, there remains less standardization specific to the kidney extraction site. This study aimed to evaluate incisional hernia occurrence in living kidney donors based on kidney extraction site location. STUDY DESIGN: This was a retrospective study of all donors who underwent minimally invasive living donor nephrectomies at the Mayo Clinic Arizona between 2011 and 2023 with a 2-year external validation cohort from Mayo Clinic Florida and Mayo Clinic Minnesota. The cohort was divided into 2 groups based on the kidney extraction site type: midline infraumbilical and Pfannenstiel. RESULTS: In the primary cohort, incisional hernia occurrence was observed in 1.2% of donors with an infraumbilical midline kidney extraction site compared with 0.1% with a Pfannenstiel extraction site (p = 0.04). Donors with an infraumbilical midline kidney extraction site were more likely to be men (50.8% vs 23.3%, p < 0.0001), have a higher BMI (mean 27.2 vs 26 kg/m2, p < 0.0001), and have current or former tobacco use (p = 0.002). There were no differences in incisional hernia occurrence when comparing minimally invasive surgical techniques (p = 0.52). In the external validation cohort, hernia occurrence was observed in 4.5% of donors with a midline incision compared with 0.0% with a Pfannenstiel incision (p = 0.09). Using combined data from the 3 sites, the use of a Pfannenstiel incision as the extraction site was associated with significantly lower odds of developing a hernia compared with the infraumbilical midline incision (odds ratio 0.06, 95% CI 0.008 to 0.456). CONCLUSIONS: Although the risk of hernia in living kidney donors is generally low, the use of a Pfannenstiel incision for kidney extraction appears to offer an additional incremental reduction in risk.
Improved Outcomes and Resource Use With Normothermic Machine Perfusion in Liver Transplantation
Zhang, Chi , Li, Xingjie , Ohara, Stephanie , Kumm, Kayla , Cosentino, Christopher P., Aqel, Bashar , Frasco, Peter E. , Nunez-Nateras, Raphael, Hewitt, Winston R. , Harbell, Jack W. , Singer, Andrew L., Moss, Adyr A. , Reddy, Kunam S. , Mathur, Amit K. , Kumm, Kayla R, Lizaola-Mayo, Blanca C, Nguyen, Michelle , Chang, Yu‐Hui , Aqel, Bashar A. , Lizaola‐Mayo, Blanca , Nunez-Nateras, Raphael, Katariya, Nitin , Jadlowiec, Caroline C.

JAMA Surgery | January 29, 2025 | Volume: 160 | Issue: 3 | Pages: 322

10.1001/jamasurg.2024.6520 Get It

Importance Normothermic machine perfusion (NMP) has been shown to reduce peritransplant complications. Despite increasing NMP use in liver transplant (LT), there is a scarcity of real-world clinical experience data. Objective To compare LT outcomes between donation after brain death (DBD) and donation after circulatory death (DCD) allografts preserved with NMP or static cold storage (SCS). Design, Setting, and Participants This single-center, retrospective observational cohort study included all consecutive adult LTs performed between January 2019 and December 2023 at the Mayo Clinic in Arizona. Data analysis was performed between February 2024 and June 2024. Outcomes of DBD-SCS, DBD-NMP, DCD-SCS, and DCD-NMP transplants were compared. Exposure DBD and DCD livers preserved on NMP or SCS. Main Outcomes and Measures The primary outcomes were early allograft dysfunction (EAD), intraoperative transfusion, and post-LT hospital resource use, including length of stay (LOS) and readmissions. Secondary outcomes included acute kidney injury (AKI) and 1-year graft and patient survival. Results A total of 1086 LTs were included in the following 4 groups: DBD-SCS (n = 480), DBD-NMP (n = 63), DCD-SCS (n = 264), and DCD-NMP (n = 279). Among LT recipients, median (IQR) age was 60.0 years (52.0-66.0); 399 LT recipients (36.7%) were female. DCD-NMP had the lowest EAD rate (17.5%), followed by DCD-SCS (50.0%), DBD-NMP (36.8%), and DBD-SCS (27.3%) ( P &amp;lt; .001). DCD-NMP had the lowest intraoperative transfusion requirement compared to all other groups. Hospital and intensive care unit (ICU) LOS were shortest in DCD-NMP (median [IQR] hospital LOS, 5.0 days [4.0-7.0]; P = .01; median [IQR] ICU LOS, 1.5 days [1.2-3.1]; P = .01). One-year cumulative readmission probability was 86% lower for DCD-NMP vs DCD-SCS (95% CI, 0.09-0.22; P &amp;lt; .001) and 53% lower for DBD-NMP vs DBD-SCS (95% CI, 0.26-0.87; P &amp;lt; .001). AKI events were lower in DCD-NMP (31.1%) vs DCD-SCS (47.4%) ( P = .001). Compared to SCS, the NMP group had a 78% overall reduction in graft failure (hazard ratio [HR], 0.22; 95% CI, 0.10-0.49; P &amp;lt; .001). For those receiving DCD allografts, the risk reduction was even more pronounced, with an 87% decrease in graft failure (HR, 0.13; 95% CI, 0.05-0.33; P &amp;lt; .001). NMP was significantly protective from patient mortality vs SCS (HR, 0.31; 95% CI, 0.12-0.80; P = .02). Conclusions and Relevance In this observational high-volume cohort study, NMP significantly improved LT clinical outcomes and reduced hospital resource use, especially in DCD allografts. NMP may enhance access to LT by addressing the challenges historically linked with DCD liver use.
Donation After Circulatory Death Liver Transplantation: Impact of Normothermic Machine Perfusion on Key Variables
Stoker, Alexander D., Gorlin, Andrew , Rosenfeld, David M. , Mathur, Amit K. , Buckner‐Petty, Skye , Frasco, Peter E. , Gorlin, Andrew W, Buckner-Petty, Skye A, Lizaola-Mayo, Blanca C, Nguyen, Michelle , Lizaola‐Mayo, Blanca

Anesthesia & Analgesia | January 14, 2025 | Volume: 140 | Issue: 3 | Pages: 687-696

10.1213/ane.0000000000007093 Get It

BACKGROUND: During orthotopic liver transplantation, allograft reperfusion is a dynamic point in the operation and often requires vasoactive medications and blood transfusions. Normothermic machine perfusion (NMP) of liver allografts has emerged to increase the number of transplantable organs and may have utility during donation after circulatory death (DCD) liver transplantation in reducing transfusion burden and vasoactive medication requirements. METHODS: This is a single-center retrospective study involving 226 DCD liver transplant recipients who received an allograft transported with NMP (DCD-NMP group) or with static cold storage (DCD-SCS group). Veno-venous bypass was not used in any patients. Infusion doses of norepinephrine, epinephrine, and vasopressin as well as bolus doses of vasoactive medications during reperfusion were recorded. Blood component therapy was recorded according to phase of liver transplantation and during the first 24 hours postprocedure. RESULTS: A total of 103 recipients in the DCD-NMP group and 123 patients in the DCD-SCS group were included. Post-reperfusion syndrome (PRS) incidence was reduced in the DCD-NMP group compared to the DCD-SCS group (10.7% [95% confidence interval, CI, 5.5%–18.3%] vs 42.3% [95% CI, 33.4%–51.5%]; P < .001). During the reperfusion period, patients in the DCD-SCS group required increased bolus doses of epinephrine and vasopressin compared to the DCD-NMP group (24.6 vs 7.5 µg; P < .001) and (5.4 vs 2.4 units; P < .001), respectively. The DCD-SCS group received a higher infusion dose of epinephrine during anhepatic phase, at reperfusion, and up to 90 minutes after reperfusion. In the postreperfusion period, there were significant increases in the transfusion of red blood cells (RBCs; 5.3 vs 3.7 units; P = .006), fresh frozen plasma (FFP; 3.4 vs 1.9 units; P < .001), cryoprecipitate (2.7 vs 1.8 pooled units; P = .015) and platelets (0.9 vs 0.4 units; P = .008) in the DCD-SCS group compared to the DCD-NMP group. During the first 24 hours postprocedure, transfusion of RBCs, FFP, and cryoprecipitate in the DCD-SCS group was increased compared to the DCD-NMP group ([2.6 vs 1.7 units; P = .028], [1.6 vs 0.8 units; P < .001], [1.5 vs 0.9 pooled units; P = .031]) respectively. Administration of tranexamic acid was more frequent in the DCD-SCS group during the post-reperfusion period compared to the DCD-NMP group (13% [95% CI, 5.7%–17.4%] vs 3.9% [95% CI, 1.1%–9.6% 95%]; P = .018). CONCLUSIONS: In DCD liver transplantation, use of NMP was associated with reduced incidence of PRS and decreased vasopressor and inotrope requirements at the time of allograft reperfusion compared to using SCS. Additionally, NMP was associated with reduced transfusion of all blood product components as well as antifibrinolytic agent administration in the post-reperfusion period. Reduced transfusion burden in the DCD-NMP group also occurred during the first 24 hours posttransplant.