Back to Authors

Mandrekar, Jayawant N.

https://orcid.org/0000-0002-9718-4082

Mayo Clinic

Mayo Clinic

Citations 122

MRI Accuracy for Tears of the Posterior Horn of the Lateral Meniscus in Patients With Acute Anterior Cruciate Ligament Injury and the Clinical Relevance of Missed Tears
Laundre, Bryan J., Collins, Mark S., Bond, Jeffrey R., Dahm, Diane L., Mandrekar, Jayawant N. , Stuart, Michael J.

American Journal of Roentgenology | July 20, 2009 | Volume: 193 | Issue: 2 | Pages: 515-523

10.2214/ajr.08.2146 Get It

Autoimmune Pancreatitis: Differentiation From Pancreatic Carcinoma and Normal Pancreas on the Basis of Enhancement Characteristics at Dual-Phase CT
Takahashi, Naoki , Hough, David M., Fidler, Jeff L. , Mandrekar, Jayawant N. , Chari, Suresh T. , Fletcher, Joel G. , Fidler, Jeff L. , Kawashima, Akira , Takahashi, Naoki , Chari, Suresh T

American Journal of Roentgenology | July 20, 2009 | Volume: 193 | Issue: 2 | Pages: 479-484

10.2214/ajr.08.1883 Get It

Prospective Comparison of State-of-the-Art MR Enterography and CT Enterography in Small-Bowel Crohn's Disease
Siddiki, Hassan , Fidler, Jeff L. , Burton, Sharon S., Huprich, James E., Hough, David M., Johnson, C. Daniel, Bruining, David H. , Loftus, Edward V. , Sandborn, William J. , Pardi, Darrell S. , Mandrekar, Jayawant N. , Fidler, Jeff L. , Fletcher, Joel G. , Loftus, Edward V

American Journal of Roentgenology | June 19, 2009 | Volume: 193 | Issue: 1 | Pages: 113-121

10.2214/ajr.08.2027 Get It

Anidulafungin Treatment of Candidal Central Nervous System Infection in a Murine Model
Rouse, Mark S., Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Kang, Cheol‐In , Patel, Robin

Antimicrobial Agents and Chemotherapy | June 9, 2009 | Volume: 53 | Issue: 8 | Pages: 3576-3578

10.1128/aac.00646-09 Get It

ABSTRACT We established a murine model of Candida albicans central nervous system (CNS) infection and evaluated the efficacy of anidulafungin. Ten milligrams/kg/day anidulafungin, amphotericin B, or voriconazole significantly reduced mortality and fungal burden in brain tissue, although amphotericin B and 10 mg/kg/day anidulafungin reduced fungal burden in brain tissue to a greater extent than did voriconazole. This suggests a potential role for anidulafungin in the treatment of candidal CNS infection.
Dietary Supplement S -Adenosyl- l -Methionine (AdoMet) Effects on Plasma Homocysteine Levels in Healthy Human Subjects: A Double-Blind, Placebo-Controlled, Ra
Bauer, Brent A. , Loehrer, Laura L., Cha, Stephen S., Mandrekar, Jayawant N. , Sood, Amit , Wahner‐Roedler, Dietlind L. , Thompson, Michael A. , Cha, Stephen S.

The Journal of Alternative and Complementary Medicine | May 7, 2009 | Volume: 15 | Issue: 5 | Pages: 523-529

10.1089/acm.2008.0402 Get It

Microbiologic Diagnosis of Prosthetic Shoulder Infection by Use of Implant Sonication
Piper, Kerryl E., Jacobson, Melissa, Cofield, Robert H. , Sperling, John W. , Osmon, Douglas R. , McDowell, Andrew , Patrick, Sheila , Steckelberg, James M., Mandrekar, Jayawant N. , Sampedro, Marta Fernández , Patel, Robin , Sánchez‐Sotelo, Joaquín , Patel, Robin

Journal of Clinical Microbiology | March 5, 2009 | Volume: 47 | Issue: 6 | Pages: 1878-1884

10.1128/jcm.01686-08 Get It

ABSTRACT We recently described a sonication technique for the diagnosis of prosthetic knee and hip infections. We compared periprosthetic tissue culture to implant sonication followed by sonicate fluid culture for the diagnosis of prosthetic shoulder infection. One hundred thirty-six patients undergoing arthroplasty revision or resection were studied; 33 had definite prosthetic shoulder infections and 2 had probable prosthetic shoulder infections. Sonicate fluid culture was more sensitive than periprosthetic tissue culture for the detection of definite prosthetic shoulder infection (66.7 and 54.5%, respectively; P = 0.046). The specificities were similar (98.0% and 95.1%, respectively; P = 0.26). Propionibacterium acnes was the commonest species detected among culture-positive definite prosthetic shoulder infection cases by periprosthetic tissue culture (38.9%) and sonicate fluid culture (40.9%). All subjects from whom P. acnes was isolated from sonicate fluid were male. We conclude that sonicate fluid culture is useful for the diagnosis of prosthetic shoulder infection.
Pilot Study of Association of Bacteria on Breast Implants with Capsular Contracture
Pozo, José Luís del , Tran, Nho V. , Petty, Paul M., Johnson, C. H. , Walsh, Molly F., Bite, Uldis, Clay, Ricky P., Mandrekar, Jayawant N. , Piper, Kerryl E., Steckelberg, James M., Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | March 5, 2009 | Volume: 47 | Issue: 5 | Pages: 1333-1337

10.1128/jcm.00096-09 Get It

ABSTRACT Capsular contracture is the most common and frustrating complication in women who have undergone breast implantation. Its cause and, accordingly, treatment and prevention remain to be elucidated fully. The aim of this prospective observational pilot study was to test the hypothesis that the presence of bacteria on breast implants is associated with capsular contracture. We prospectively studied consecutive patients who underwent breast implant removal for reasons other than overt infection at the Mayo Clinic from February through September 2008. Removed breast implants were processed using a vortexing/sonication procedure and then subjected to semiquantitative culture. Twenty-seven of the 45 implants collected were removed due to significant capsular contracture, among which 9 (33%) had ≥20 CFU bacteria/10 ml sonicate fluid; 18 were removed for reasons other than significant capsular contracture, among which 1 (5%) had ≥20 CFU/10 ml sonicate fluid ( P = 0.034). Propionibacterium species, coagulase-negative staphylococci, and Corynebacterium species were the microorganisms isolated. The results of this study demonstrate that there is a significant association between capsular contracture and the presence of bacteria on the implant. The role of these bacteria in the pathogenesis of capsular contracture deserves further study.
Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
Sloma, Cari R., Germer, Jeffrey J., Gerads, Tara M., Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | February 5, 2009 | Volume: 47 | Issue: 4 | Pages: 889-895

10.1128/jcm.02231-08 Get It

ABSTRACT The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results ( r = 0.95) among clinical specimens, with a mean difference of −0.34 log 10 copies/ml. Testing of healthy donor plasma specimens yielded “target not detected” results by ART, with “HIV-1 RNA detected, <40 copies/ml” results for 3.3% (3 of 90 samples) of these specimens by CTM. Both the m2000sp/m2000rt (ART) and docked CAP/CTM96 (CTM) instrument systems were capable of operating with continuous, uninterrupted workflow. When daily maintenance and cleaning were included, ART and CTM run durations (5 h 52 min and 6 h 4 min, respectively) and hands-on times (53 min and 46 min, respectively) were similar for a run batch size of 24. While ART was more flexible in terms of run batch size, CTM required fewer user interventions and consistently produced higher specimen throughput rates at 8, 16, and 24 h. Assay run failure rates were 6.3% (1 of 16 runs) and 4.2% (1 of 24 runs) for ART and CTM, respectively ( P = 1.000), with invalid specimen result rates of 1.0% (5 of 495 specimens) and 2.8% (11 of 399 specimens), respectively ( P = 0.073). Direct reagent and consumable costs for each assay were comparable (difference of <10%). In selecting an assay for implementation, laboratories should consider how various assay and instrument features might impact laboratory operation and patient care.
The Electricidal Effect: Reduction of Staphylococcus and Pseudomonas Biofilms by Prolonged Exposure to Low-Intensity Electrical Current
Pozo, José Luís del , Rouse, Mark S., Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | October 28, 2008 | Volume: 53 | Issue: 1 | Pages: 41-45

10.1128/aac.00680-08 Get It

ABSTRACT The activity of electrical current against planktonic bacteria has previously been demonstrated. The short-term exposure of the bacteria in biofilms to electrical current in the absence of antimicrobials has been shown to have no substantial effect; however, longer-term exposure has not been studied. A previously described in vitro model was used to determine the effect of prolonged exposure (i.e., up to 7 days) to low-intensity (i.e., 20-, 200-, and 2,000-microampere) electrical direct currents on Pseudomonas aeruginosa , Staphylococcus aureus , and Staphylococcus epidermidis biofilms. Dose- and time-dependent killing was observed. A maximum of a 6-log 10 -CFU/cm 2 reduction was observed when S. epidermidis biofilms were exposed to 2,000 microamperes for at least 2 days. A 4- to 5-log 10 -CFU/cm 2 reduction was observed when S. aureus biofilms were exposed to 2,000 microamperes for at least 2 days. Finally, a 3.5- to 5-log 10 -CFU/cm 2 reduction was observed when P. aeruginosa biofilms were exposed to electrical current for 7 days. A higher electrical current intensity correlated with greater decreases in viable bacteria at all time points studied. In conclusion, low-intensity electrical current substantially reduced the numbers of viable bacteria in staphylococcal or Pseudomonas biofilms, a phenomenon we have labeled the “electricidal effect.”
Effect of Electrical Current on the Activities of Antimicrobial Agents against Pseudomonas aeruginosa , Staphylococcus aureus , and Staphylococcus epidermidis Biof
Pozo, José Luís del , Rouse, Mark S., Mandrekar, Jayawant N. , Sampedro, Marta Fernández , Steckelberg, James M., Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | August 26, 2008 | Volume: 53 | Issue: 1 | Pages: 35-40

10.1128/aac.00237-08 Get It

ABSTRACT Bacterial biofilms are resistant to conventional antimicrobial agents. Prior in vitro studies have shown that electrical current (EC) enhances the activities of aminoglycosides, quinolones, and oxytetracycline against Pseudomonas aeruginosa , Klebsiella pneumoniae , Staphylococcus epidermidis , Escherichia coli , and Streptococcus gordonii . This phenomenon, known as the bioelectric effect, has been only partially defined. The purpose of this work was to study the in vitro bioelectric effect on the activities of 11 antimicrobial agents representing a variety of different classes against P. aeruginosa , methicillin-resistant Staphylococcus aureus (MRSA), and S. epidermidis . An eight-channel current generator/controller and eight chambers delivering a continuous flow of fresh medium with or without antimicrobial agents and/or EC to biofilm-coated coupons were used. No significant decreases in the numbers of log 10 CFU/cm 2 were seen after exposure to antimicrobial agents alone, with the exception of a 4.57-log-unit reduction for S. epidermidis and trimethoprim-sulfamethoxazole. We detected a statistically significant bioelectric effect when vancomycin plus 2,000 microamperes EC were used against MRSA biofilms ( P = 0.04) and when daptomycin and erythromycin were used in combination with 200 or 2,000 microamperes EC against S. epidermidis biofilms ( P = 0.02 and 0.0004, respectively). The results of these experiments indicate that the enhancement of the activity of antimicrobial agents against biofilm organisms by EC is not a generalizable phenomenon across microorganisms and antimicrobial agents.