Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.
Bile Acid Profiles in Primary Sclerosing Cholangitis and Their Ability to Predict Hepatic Decompensation
Background and Aims Altered bile acid (BA) homeostasis is an intrinsic facet of cholestatic liver diseases, but clinical usefulness of plasma BA assessment in primary sclerosing cholangitis (PSC) remains understudied. We performed BA profiling in a large retrospective cohort of patients with PSC and matched healthy controls, hypothesizing that plasma BA profiles vary among patients and have clinical utility. Approach and Results Plasma BA profiling was performed in the Clinical Biochemical Genetics Laboratory at Mayo Clinic using a mass spectrometry based assay. Cox proportional hazard (univariate) and gradient boosting machines (multivariable) models were used to evaluate whether BA variables predict 5‐year risk of hepatic decompensation (HD; defined as ascites, variceal hemorrhage, or encephalopathy). There were 400 patients with PSC and 302 controls in the derivation cohort (Mayo Clinic) and 108 patients with PSC in the validation cohort (Norwegian PSC Research Center). Patients with PSC had increased BA levels, conjugated fraction, and primary‐to‐secondary BA ratios relative to controls. Ursodeoxycholic acid (UDCA) increased total plasma BA level while lowering cholic acid and chenodeoxycholic acid concentrations. Patients without inflammatory bowel disease (IBD) had primary‐to‐secondary BA ratios between those of controls and patients with ulcerative colitis. HD risk was associated with increased concentration and conjugated fraction of many BA, whereas higher G:T conjugation ratios were protective. The machine‐learning model, PSC‐BA profile score (concordance statistic [C‐statistic], 0.95), predicted HD better than individual measures, including alkaline phosphatase, and performed well in validation (C‐statistic, 0.86). Conclusions Patients with PSC demonstrated alterations of plasma BA consistent with known mechanisms of cholestasis, UDCA treatment, and IBD. Notably, BA profiles predicted future HD, establishing the clinical potential of BA profiling, which may be suited for use in clinical trials.
Immune dysfunction in MGAT2‐CDG: A clinical report and review of the literature
AbstractGlycosylation is a critical post/peri‐translational modification required for the appropriate development and function of the immune system. As an example, abnormalities in glycosylation can cause antibody deficiency and reduced lymphocyte signaling, although the phenotype can be complex given the diverse roles of glycosylation. Human MGAT2 encodes N‐acetylglucosaminyltransferase II, which is a critical enzyme in the processing of oligomannose to complex N‐glycans. Complex N‐glycans are essential for immune system functionality, but only one individual with MGAT2‐CDG has been described to have an abnormal immunologic evaluation. MGAT2‐CDG (CDG‐IIa) is a congenital disorder of glycosylation (CDG) associated with profound global developmental disability, hypotonia, early onset epilepsy, and other multisystem manifestations. Here, we report a 4‐year old female with MGAT2‐CDG due to a novel homozygous pathogenic variant in MGAT2, a 4‐base pair deletion, c.1006_1009delGACA. In addition to clinical features previously described in MGAT2‐CDG, she experienced episodic asystole, persistent hypogammaglobulinemia, and defective ex vivo mitogen and antigen proliferative responses, but intact specific vaccine antibody titers. Her infection history has been mild despite the testing abnormalities. We compare this patient to the 15 previously reported patients in the literature, thus expanding both the genotypic and phenotypic spectrum for MGAT2‐CDG.
A Comparative Effectiveness Study of Newborn Screening Methods for Four Lysosomal Storage Disorders
Newborn screening for one or more lysosomal disorders has been implemented in several US states, Japan and Taiwan by multiplexed enzyme assays using either tandem mass spectrometry or digital microfluidics. Another multiplex assay making use of immunocapture technology has also been proposed. To investigate the potential variability in performance of these analytical approaches, we implemented three high-throughput screening assays for the simultaneous screening for four lysosomal disorders: Fabry disease, Gaucher disease, mucopolysaccharidosis type I, and Pompe disease. These assays were tested in a prospective comparative effectiveness study using nearly 100,000 residual newborn dried blood spot specimens. In addition, 2nd tier enzyme assays and confirmatory molecular genetic testing were employed. Post-analytical interpretive tools were created using the software Collaborative Laboratory Integrated Reports (CLIR) to determine its ability to improve the performance of each assay vs. the traditional result interpretation based on analyte-specific reference ranges and cutoffs. This study showed that all three platforms have high sensitivity, and the application of CLIR tools markedly improves the performance of each platform while reducing the need for 2nd tier testing by 66% to 95%. Moreover, the addition of disease-specific biochemical 2nd tier tests ensures the lowest false positive rates and the highest positive predictive values for any platform.
Genomic Analysis of Historical Cases with Positive Newborn Screens for Short-Chain Acyl-CoA Dehydrogenase Deficiency Shows That a Validated Second-Tier Biochemical Test Can Replace Future Sequencing
Short-chain acyl-CoA dehydrogenase deficiency (SCADD) is a rare autosomal recessive disorder of β-oxidation caused by pathogenic variants in the ACADS gene. Analyte testing for SCADD in blood and urine, including newborn screening (NBS) using tandem mass spectrometry (MS/MS) on dried blood spots (DBSs), is complicated by the presence of two relatively common ACADS variants (c.625G>A and c.511C>T). Individuals homozygous for these variants or compound heterozygous do not have clinical disease but do have reduced short-chain acyl-CoA dehydrogenase (SCAD) activity, resulting in elevated blood and urine metabolites. As part of a larger study of the potential role of exome sequencing in NBS in California, we reviewed ACADS sequence and MS/MS data from DBSs from a cohort of 74 patients identified to have SCADD. Of this cohort, approximately 60% had one or more of the common variants and did not have the two rare variants, and thus would need no further testing. Retrospective analysis of ethylmalonic acid, glutaric acid, 2-hydroxyglutaric acid, 3-hydroxyglutaric acid, and methylsuccinic acid demonstrated that second-tier testing applied before the release of the newborn screening result could reduce referrals by over 50% and improve the positive predictive value for SCADD to above 75%.
Achieving Congruence among Reference Laboratories for Absolute Abundance Measurement of Analytes for Rare Diseases: Psychosine for Diagnosis and Prognosis of Krabbe Disease
Measurement of the absolute concentration of the biomarker psychosine in dried blood spots (DBS) is useful for diagnosis and prognosis of Krabbe disease and to support newborn screening of this leukodystrophy. As for assays for more common diseases, it is important to achieve congruence when multiple clinical laboratories provide testing. Four clinical laboratories, one research laboratory, and a commercial vendor collaborated with the goal to achieve congruence in quantitative psychosine measurement in DBS. A set of DBS calibrators was prepared by a single vendor and used in each reference laboratory to make a standard curve of measured psychosine in DBS versus the stated calibrator psychosine level. Congruence between the participating five laboratories was achieved using the psychosine DBS calibrators. This allowed application of disease-specific reference ranges obtained by the reference laboratory with the most extensive data by the other reference laboratories. Congruence between multiple reference laboratories in the measurement of the absolute concentration of biomarkers in DBS (and by extension other samples) is possible by the use of a common set of DBS calibrators.
Simultaneous Testing for 6 Lysosomal Storage Disorders and X-Adrenoleukodystrophy in Dried Blood Spots by Tandem Mass Spectrometry
Abstract BACKGROUND Newborn screening for lysosomal storage disorders (LSD) has revealed that late-onset variants of these conditions are unexpectedly frequent and therefore may evade diagnosis. We developed an efficient and cost-effective multiplex assay to diagnose six LSDs and several peroxisomal disorders in patients presenting with diverse phenotypes at any age. METHODS Three 3-mm dried blood spot (DBS) punches were placed into individual microtiter plates. One disc was treated with a cocktail containing acid sphingomyelinase-specific substrate and internal standard (IS). To the second DBS we added a cocktail containing substrate and IS for β-glucosidase, acid α-glucosidase, α-galactosidase A, galactocerebrosidase, and α-L-iduronidase. The third DBS was extracted with methanol containing d4-C26 lysophosphatidylcholine as IS and stored until the enzyme plates were combined and purified by liquid–liquid and solid-phase extraction. The extracts were evaporated, reconstituted with the extract from the lysophosphatidylcholine plate, and analyzed by flow injection tandem mass spectrometry. RESULTS Reference intervals were determined by analysis of 550 samples from healthy controls. DBS from confirmed patients with 1 of the 6 LSDs (n = 33), X-adrenoleukodystrophy (n = 9), or a peroxisomal biogenesis disorder (n = 5), as well as carriers for Fabry disease (n = 17) and X-adrenoleukodystrophy (n = 5), were analyzed for assay validation. Prospective clinical testing of 578 samples revealed 25 patients affected with 1 of the detectable conditions. CONCLUSIONS Our flow injection tandem mass spectrometry approach is amenable to high-throughput population screening for Hurler disease, Gaucher disease, Niemann–Pick A/B disease, Pompe disease, Krabbe disease, Fabry disease, X-adrenoleukodystrophy, and peroxisomal biogenesis disorder in DBS.
Measurement of psychosine in dried blood spots — a possible improvement to newborn screening programs for Krabbe disease
AbstractBackgroundNewborn screening (NBS) for Krabbe disease (KD) in New York and Missouri is conducted by measuring galactocerebrosidase (GALC) activity using tandem mass spectrometry (MS/MS). These NBS efforts have shown that the incidence of KD is unexpectedly low (1:400,000) while many individuals (ca. 1:6000) with reduced GALC activity and genotypes of uncertain significance are detected and subjected to follow up testing. Psychosine (PSY) is a putative marker of KD progression and can be measured in dried blood spots (DBS). We sought to determine the role that PSY levels play in NBS for KD, follow up, and treatment monitoring.MethodsPSY was eluted from DBS with methanol containing N,N‐dimethyl‐D‐erythro‐sphingosine as internal standard (IS). Liquid chromatography‐MS/MS was conducted over 17 minutes in the multiple reaction monitoring positive mode to follow the precursor to product species transitions for PSY and IS. Separation of the structural isomers PSY and glucosylsphingosine was accomplished by hydrophilic interaction liquid chromatography.ResultsPre‐analytical and analytical factors were studied and revealed satisfactory results. PSY was also measured in DBS collected from controls (range: <8 nmol/L, N = 220), KD patients at various disease stages (range: 8–112, N = 26), and GALC mutation carriers (range: <15 nmol/L, N = 18).ConclusionsPSY measurement in DBS could serve as a 2nd tier assay in NBS for KD, simplify and reduce the cost of follow up protocols, help determine disease progression, and be used to monitor KD patients following hematopoietic stem cell transplantation. However, additional chronological measurements of PSY in KD patients are required to confirm these possibilities.