Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.
Improved Stable Isotope Dilution-Gas Chromatography-Mass Spectrometry Method for Serum or Plasma Free 3-Hydroxy-Fatty Acids and Its Utility for the Study of Disorders of Mitochondrial Fatty Acid β-Oxidation
Abstract Background: Disorders of fatty acid oxidation (FAO) are difficult to diagnose, primarily because in many of the FAO disorders measurable biochemical intermediates accumulate in body fluids only during acute illness. Increased concentrations of 3-hydroxy-fatty acids (3-OH-FAs) in the blood are indicative of FAO disorders of the long- and short-chain 3-hydroxy-acyl-CoA dehydrogenases, LCHAD and SCHAD. We describe a serum/plasma assay for the measurement of 3-OH-FAs with carbon chain lengths from C6 to C16. Methods: We used stable isotope dilution gas chromatography-mass spectrometry (GC-MS) with electron impact ionization and selected ion monitoring. Natural and isotope-labeled compounds were synthesized for the assay. Results: The assay was linear from 0.2 to 50 μmol/L for all six 3-OH-FAs. CVs were 5–15% at concentrations near the upper limits seen in healthy subjects. In 43 subjects, the medians (and ranges) in μmol/L were as follows: 3-OH-C6, 0.8 (0.3–2.2); 3-OH-C8, 0.4 (0.2–1.0); 3-OH-C10, 0.3 (0.2–0.6); 3-OH-C12, 0.3 (0.2–0.6); 3-OH-C14, 0.2 (0.0–0.4); and 3-OH-C16, 0.2 (0.0–0.5). 3-OH-FAs were increased in infants receiving formula containing medium chain triglycerides. Two patients diagnosed with LCHAD deficiency showed marked increases in 3-OH-C14 and 3-OH-C16 concentrations. Two patients diagnosed with SCHAD deficiency showed increased shorter chain 3-OH-FAs but no increases in 3-OH-C14 to 3-OH-C16. Conclusion: Measuring blood concentrations of the 3-OH-FAs with this assay may be a valuable tool for helping to rapidly identify deficiencies in LCHAD and SCHAD and may also provide useful information about the status of the FAO pathway.