Department of Pediatrics, University of California, San Francisco, CA 94143, USA.
Citations 5
A Novel Approach to Improve Newborn Screening for Congenital Hypothyroidism by Integrating Covariate-Adjusted Results of Different Tests into CLIR Customized Interpretive Tools
Newborn screening for congenital hypothyroidism remains challenging decades after broad implementation worldwide. Testing protocols are not uniform in terms of targets (TSH and/or T4) and protocols (parallel vs. sequential testing; one or two specimen collection times), and specificity (with or without collection of a second specimen) is overall poor. The purpose of this retrospective study is to investigate the potential impact of multivariate pattern recognition software (CLIR) to improve the post-analytical interpretation of screening results. Seven programs contributed reference data (N = 1,970,536) and two sets of true (TP, N = 1369 combined) and false (FP, N = 15,201) positive cases for validation and verification purposes, respectively. Data were adjusted for age at collection, birth weight, and location using polynomial regression models of the fifth degree to create three-dimensional regression surfaces. Customized Single Condition Tools and Dual Scatter Plots were created using CLIR to optimize the differential diagnosis between TP and FP cases in the validation set. Verification testing correctly identified 446/454 (98%) of the TP cases, and could have prevented 1931/5447 (35%) of the FP cases, with variable impact among locations (range 4% to 50%). CLIR tools either as made here or preferably standardized to the recommended uniform screening panel could improve performance of newborn screening for congenital hypothyroidism.
The Clinical Impact of CLIR Tools toward Rapid Resolution of Post-Newborn Screening Confirmatory Testing for X-Linked Adrenoleukodystrophy in California
Since the start of X-linked adrenoleukodystrophy (ALD) newborn screening in California, more than half of the diagnosed cases were found to have an ATP binding cassette subfamily D member 1 (ABCD1) gene variant of uncertain significance (VUS). To determine retrospectively the likelihood that these were true positive cases, we used a web-based post-analytical tool in Collaborative Laboratory Integrated Reports (CLIR). Confirmatory plasma very long-chain fatty-acids (VLCFA) profiles for ALD screen positive infant boys were run through the CLIR ALD tool. We compared the distribution by ABCD1 variant classification (pathogenic, likely pathogenic, VUS, and no variant) with the CLIR tool score interpretation (non-informative, possibly ALD, likely ALD, and very likely ALD) and the current case diagnosis. The study showed that CLIR tool positive interpretations were consistent with 100% of the pathogenic and likely pathogenic variants on the ABCD1 gene if a more conservative guideline was used. The tool interpretations were also consistent with screened cases that were determined to not have disease (our no-disorder group). The CLIR tool identified 19 diagnosed ALD cases with VUS to be potential false positives, representing a 40% reduction among all diagnosed ALD cases with VUS. The reduction could be extended to 65% if a more aggressive threshold was used. Identifying such preventable false positives could alleviate the follow-up burden for patients, their families, and California Special Care Centers.
A Comparative Effectiveness Study of Newborn Screening Methods for Four Lysosomal Storage Disorders
Newborn screening for one or more lysosomal disorders has been implemented in several US states, Japan and Taiwan by multiplexed enzyme assays using either tandem mass spectrometry or digital microfluidics. Another multiplex assay making use of immunocapture technology has also been proposed. To investigate the potential variability in performance of these analytical approaches, we implemented three high-throughput screening assays for the simultaneous screening for four lysosomal disorders: Fabry disease, Gaucher disease, mucopolysaccharidosis type I, and Pompe disease. These assays were tested in a prospective comparative effectiveness study using nearly 100,000 residual newborn dried blood spot specimens. In addition, 2nd tier enzyme assays and confirmatory molecular genetic testing were employed. Post-analytical interpretive tools were created using the software Collaborative Laboratory Integrated Reports (CLIR) to determine its ability to improve the performance of each assay vs. the traditional result interpretation based on analyte-specific reference ranges and cutoffs. This study showed that all three platforms have high sensitivity, and the application of CLIR tools markedly improves the performance of each platform while reducing the need for 2nd tier testing by 66% to 95%. Moreover, the addition of disease-specific biochemical 2nd tier tests ensures the lowest false positive rates and the highest positive predictive values for any platform.
Genomic Analysis of Historical Cases with Positive Newborn Screens for Short-Chain Acyl-CoA Dehydrogenase Deficiency Shows That a Validated Second-Tier Biochemical Test Can Replace Future Sequencing
Short-chain acyl-CoA dehydrogenase deficiency (SCADD) is a rare autosomal recessive disorder of β-oxidation caused by pathogenic variants in the ACADS gene. Analyte testing for SCADD in blood and urine, including newborn screening (NBS) using tandem mass spectrometry (MS/MS) on dried blood spots (DBSs), is complicated by the presence of two relatively common ACADS variants (c.625G>A and c.511C>T). Individuals homozygous for these variants or compound heterozygous do not have clinical disease but do have reduced short-chain acyl-CoA dehydrogenase (SCAD) activity, resulting in elevated blood and urine metabolites. As part of a larger study of the potential role of exome sequencing in NBS in California, we reviewed ACADS sequence and MS/MS data from DBSs from a cohort of 74 patients identified to have SCADD. Of this cohort, approximately 60% had one or more of the common variants and did not have the two rare variants, and thus would need no further testing. Retrospective analysis of ethylmalonic acid, glutaric acid, 2-hydroxyglutaric acid, 3-hydroxyglutaric acid, and methylsuccinic acid demonstrated that second-tier testing applied before the release of the newborn screening result could reduce referrals by over 50% and improve the positive predictive value for SCADD to above 75%.
Newborn Screening for Severe Combined Immunodeficiency in 11 Screening Programs in the United States