Back to Authors

McCollough, Cynthia

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, Minnesota.

Citations 19

Estimating a size‐specific dose for helical head CT examinations using Monte Carlo simulation methods
Hardy, Anthony J. , Bostani, Maryam, Hernandez, Andrew M. , Zankl, M. , Cagnon, Chris H., Boone, John M. , McCollough, Cynthia, McCollough, Cynthia H. , McNitt‐Gray, Michael F.

Medical Physics | December 19, 2018 | Volume: 46 | Issue: 2 | Pages: 902-912

10.1002/mp.13301 Get It

PurposeSize‐specific dose estimates (SSDE) conversion factors have been determined byAAPMReport 204 to adjustCTDIvolto account for patient size but were limited to bodyCTexaminations. The purpose of this work was to determine conversion factors that could be used for anSSDEfor helical, headCTexaminations for patients of different sizes.MethodsValidated Monte Carlo (MC) simulation methods were used to estimate dose to the center of the scan volume from a routine, helical head examination for a group of patient models representing a range of ages and sizes. Ten GSF/ICRP voxelized phantom models and five pediatric voxelized patient models created from CT image data were used in this study. CT scans were simulated using a Siemens multidetector row CT equivalent source model. Scan parameters were taken from the AAPM Routine Head protocols for a fixed tube current (FTC), helical protocol, and scan lengths were adapted to the anatomy of each patient model. MC simulations were performed using mesh tallies to produce voxelized dose distributions for the entire scan volume of each model. Three tally regions were investigated: (1) a small 0.6 cc volume at the center of the scan volume, (2) 0.8–1.0 cm axial slab at the center of the scan volume, and (3) the entire scan volume. Mean dose to brain parenchyma for all three regions was calculated. Mean bone dose and a mass‐weighted average dose, consisting of brain parenchyma and bone, were also calculated for the slab in the central plane and the entire scan volume. All dose measures were then normalized by CTDIvolfor the 16 cm phantom (CTDIvol,16). Conversion factors were determined by calculating the relationship between normalized doses and water equivalent diameter (Dw).ResultsCTDIvol,16‐normalized mean brain parenchyma dose values within the 0.6 cc volume, 0.8–1.0 cm central axial slab, and the entire scan volume, when parameterized byDw, had an exponential relationship with a coefficient of determination (R2) of 0.86, 0.84, and 0.88, respectively. There was no statistically significant difference between the conversion factors resulting from these three different tally regions. Exponential relationships between CTDIvol,16‐normalized mean bone doses hadR2values of 0.83 and 0.87 for the central slab and for the entire scan volume, respectively. CTDIvol,16‐normalized mass‐weighted average doses hadR2values of 0.39 and 0.51 for the central slab and for the entire scan volume, respectively.ConclusionsConversion factors that describe the exponential relationship between CTDIvol,16‐normalized mean brain dose and a size metric (Dw) for helical head CT examinations have been reported for two different interpretations of the center of the scan volume. These dose descriptors have been extended to describe the dose to bone in the center of the scan volume as well as a mass‐weighted average dose to brain and bone. These may be used, when combined with other efforts, to develop an SSDE dose coefficients for routine, helical head CT examinations.
Estimating lung, breast, and effective dose from low‐dose lung cancer screening CT exams with tube current modulation across a range of patient sizes
Hardy, Anthony J. , Bostani, Maryam, McMillan, Kyle, Zankl, M. , Cagnon, Chris H., McCollough, Cynthia, McCollough, Cynthia H. , McNitt‐Gray, Michael F.

Medical Physics | August 17, 2018 | Volume: 45 | Issue: 10 | Pages: 4667-4682

10.1002/mp.13131 Get It

PurposeThe purpose of this study was to estimate the radiation dose to the lung and breast as well as the effective dose from tube current modulated (TCM) lung cancer screening (LCS) scans across a range of patient sizes.MethodsMonte Carlo (MC) methods were used to calculate lung, breast, and effective doses from a low‐dose LCS protocol for a 64‐slice CT that used TCM. Scanning parameters were from the protocols published by AAPM's Alliance for Quality CT. To determine lung, breast, and effective doses from lung cancer screening, eight GSF/ICRP voxelized phantom models with all radiosensitive organs identified were used to estimate lung, breast, and effective doses. Additionally, to extend the limited size range provided by the GSF/ICRP phantom models, 30 voxelized patient models of thoracic anatomy were generated from LCS patient data. For these patient models, lung and breast were semi‐automatically segmented. TCM schemes for each of the GSF/ICRP phantom models were generated using a validated method wherein tissue attenuation and scanner limitations were used to determine the TCM output as a function of table position and source angle. TCM schemes for voxelized patient models were extracted from the raw projection data. The water equivalent diameter, Dw, was used as the patient size descriptor. Dw was estimated for the GSF/ICRP models. For the thoracic patient models, Dw was extracted from the DICOM header of the CT localizer radiograph. MC simulations were performed using the TCM scheme for each model. Absolute organ doses were tallied and effective doses were calculated using ICRP 103 tissue weighting factors for the GSF/ICRP models. Metrics of scanner radiation output were determined based on each model's TCM scheme, including CTDIvol, dose length product (DLP), and CTDIvol, Low Att, a previously described regional metric of scanner output covering most of the lungs and breast. All lung and breast doses values were normalized by scan‐specific CTDIvol and CTDIvol, Low Att. Effective doses were normalized by scan‐specific CTDIvol and DLP. Absolute and normalized doses were reported as a function of Dw.ResultsLung doses normalized by CTDIvol, Low Att were modeled as an exponential relationship with respect to Dw with coefficients of determination (R2) of 0.80. Breast dose normalized by CTDIvol, Low Att was modeled with an exponential relationship to Dw with an R2 of 0.23. For all eight GSF/ICRP phantom models, the effective dose using TCM protocols was below 1.6 mSv. Effective doses showed some size dependence but when normalized by DLP demonstrated a constant behavior.ConclusionLung, breast, and effective doses from LCS CT exams with TCM were estimated with respect to patient size. Normalized lung dose can be reasonably estimated with a measure of a patient size such as Dw and regional metric of CTDIvol covering the thorax such as CTDIvol, Low Att, while normalized breast dose can also be estimated with a regional metric of CTDIvol but with a larger degree of variability than observed for lung. Effective dose normalized by DLP can be estimated with a constant multiplier.
Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system
Zhou, Wei , Montoya, Juan , McCollough, Cynthia, McCollough, Cynthia H , Leng, Shuai , Zhou, Wei , Montoya, Juan, Gutjahr, Ralf, Ferrero, Andrea, Halaweish, Ahmed F , Kappler, Steffen

Journal of Medical Imaging | November 16, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.043502 Get It

A comparison of relative proton stopping power measurements across patient size using dual- and single-energy CT
Michalak, Gregory J. , Taasti, Vicki Trier , Krauß, Bernhard , Deisher, A., Halaweish, Ahmed F., Deisher, Amanda, McCollough, Cynthia, McCollough, Cynthia H.

Acta Oncologica | September 8, 2017 | Volume: 56 | Issue: 11 | Pages: 1465-1471

10.1080/0284186x.2017.1372625 Get It

Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets
Zhou, Wei , Yu, Zhicong , Halaweish, Ahmed, Krauß, Bernhard , Schmidt, Bernhard , Yu, Lifeng , Kappler, S. , McCollough, C, McCollough, Cynthia, Leng, Shuai , Halaweish, Ahmed, Yu, Lifeng , Zhou, Wei

Physics in Medicine & Biology | July 20, 2017 | Volume: 62 | Issue: 17 | Pages: 7216-7232

10.1088/1361-6560/aa8103 Get It

Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.
Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
Brinjikji, Waleed , Michalak, Gregory J. , Kadirvel, Ramanathan , Gilvarry, Michael , Duffy, Sharon , Kallmes, David F. , Dai, Daying , McCollough, Cynthia, McCollough, Cynthia H. , Leng, Shuai

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 Get It

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.
Technical Note: Insertion of digital lesions in the projection domain for dual‐source, dual‐energy CT
Ferrero, Andrea , Chen, Baiyu , Li, Zhoubo , Yu, Lifeng , McCollough, Cynthia, Yu, Lifeng , McCollough, Cynthia H.

Medical Physics | February 27, 2017 | Volume: 44 | Issue: 5 | Pages: 1655-1660

10.1002/mp.12185 Get It

PurposeTo compare algorithms performing material decomposition and classification in dual‐energy CT, it is desirable to know the ground truth of the lesion to be analyzed in real patient data. In this work, we developed and validated a framework to insert digital lesions of arbitrary chemical composition into patient projection data acquired on a dual‐source, dual‐energy CT system.MethodsA model that takes into account beam‐hardening effects was developed to predict the CT number of objects with known chemical composition. The model utilizes information about the x‐ray energy spectra, the patient/phantom attenuation, and the x‐ray detector energy response. The beam‐hardening model was validated on samples of iodine (I) and calcium (Ca) for a second‐generation dual‐source, dual‐energy CT scanner for all tube potentials available and a wide range of patient sizes. The seven most prevalent mineral components of renal stones were modeled and digital stones were created with CT numbers computed for each patient/phantom size and x‐ray energy spectra using the developed beam‐hardening model. Each digital stone was inserted in the dual‐energy projection data of a water phantom scanned on a dual‐source scanner and reconstructed with the routine algorithms in use in our practice. The geometry of the forward projection for dual‐energy data was validated by comparing CT number accuracy and high‐contrast resolution of simulated dual‐energy CT data of the ACR phantom with experimentally acquired data.ResultsThe beam‐hardening model and forward projection method accurately predicted the CT number of I and Ca over a wide range of tube potentials and phantom sizes. The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner, and the CT number ratios for different kidney stone types were consistent with data in the literature. A sample application of the proposed tool was also demonstrated.ConclusionA framework was developed and validated for the creation of digital objects of known mineral composition, and for inserting the digital objects into projection data from a commercial dual‐source, dual‐energy CT scanner. Among other applications, it will allow a systematic investigation of the impact of scan and reconstruction parameters on kidney stone dual‐energy properties under rigorously controlled conditions.
Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system
Yu, Zhicong , Halaweish, Ahmed F., Kappler, S. , Hähn, Katharina, Henning, André , Li, Zhoubo , Lane, John I. , Levin, David L. , Jorgensen, Steven M., Ritman, Erik L., Lane, John , Jorgensen, Steven, Ritman, Erik, McCollough, Cynthia, Leng, Shuai , McCollough, Cynthia H. , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 Get It

Risks, Benefits, and Risk Reduction Strategies in Thoracic CT Imaging
Duan, Xinhui , McCollough, C, McCollough, Cynthia

Seminars in Respiratory and Critical Care Medicine | January 30, 2014 | Volume: 35 | Issue: 01 | Pages: 083-090

10.1055/s-0033-1363454 Get It