Abstract Background An international Delphi panel has defined a harmonized protocol (HarP) for the manual segmentation of the hippocampus on MR. The aim of this study is to study the concurrent validity of the HarP toward local protocols, and its major sources of variance. Methods Fourteen tracers segmented 10 Alzheimer's Disease Neuroimaging Initiative (ADNI) cases scanned at 1.5 T and 3T following local protocols, qualified for segmentation based on the HarP through a standard web‐platform and resegmented following the HarP. The five most accurate tracers followed the HarP to segment 15 ADNI cases acquired at three time points on both 1.5 T and 3T. Results The agreement among tracers was relatively low with the local protocols (absolute left/right ICC 0.44/0.43) and much higher with the HarP (absolute left/right ICC 0.88/0.89). On the larger set of 15 cases, the HarP agreement within (left/right ICC range: 0.94/0.95 to 0.99/0.99) and among tracers (left/right ICC range: 0.89/0.90) was very high. The volume variance due to different tracers was 0.9% of the total, comparing favorably to variance due to scanner manufacturer (1.2), atrophy rates (3.5), hemispheric asymmetry (3.7), field strength (4.4), and significantly smaller than the variance due to atrophy (33.5%, P < .001), and physiological variability (49.2%, P < .001). Conclusions The HarP has high measurement stability compared with local segmentation protocols, and good reproducibility within and among human tracers. Hippocampi segmented with the HarP can be used as a reference for the qualification of human tracers and automated segmentation algorithms.
Mean upper cervical cord area (MUCCA) measurement in long-standing multiple sclerosis: Relation to brain findings and clinical disability
Background: The majority of patients with multiple sclerosis (MS) present with spinal cord pathology. Spinal cord atrophy is thought to be a marker of disease severity, but in long-disease duration its relation to brain pathology and clinical disability is largely unknown. Objective: Our aim was to investigate mean upper cervical cord area (MUCCA) in patients with long-standing MS and assess its relation to brain magnetic resonance imaging (MRI) measures and clinical disability. Methods: MUCCA was measured in 196 MS patients and 55 healthy controls using 3DT1-weighted cervical images obtained at 3T MRI. Clinical disability was measured using the Expanded Disability Status Scale (EDSS), Nine-Hole-Peg test (9-HPT), and 25 feet Timed Walk Test (TWT). Stepwise linear regression was performed to assess the association between MUCCA and MRI measures, and between MUCCA and clinical disability. Results: MUCCA was smaller (mean 11.7%) in MS patients compared with healthy controls (72.56±9.82 and 82.24±7.80 mm 2 respectively; p<0.001), most prominently in male patients. MUCCA was associated with normalized brain volume, and number of cervical cord lesions. MUCCA was independently associated with EDSS, TWT, and 9-HPT. Conclusion: MUCCA was reduced in MS patients compared with healthy controls. It provides a relevant marker for clinical disability in long-standing disease, independent of other MRI measures.
P4–372: Validation of the EADC‐ADNI Harmonized Protocol for Manual Hippocampal Segmentation: Preliminary Results
Background and purposeThe European Federation of the Neurological Societies (EFNS) guidelines on the use of neuroimaging in the diagnosis and management of dementia are designed to revise and expand previous EFNS recommendations for the diagnosis and management of patients with Alzheimer's disease (AD) and to provide an overview of the evidence for the use of neuroimaging techniques in non‐AD dementias, as well as general recommendations that apply to all types of dementia in clinical practice.MethodsThe task force working group reviewed evidence from original research articles, meta‐analyses and systematic reviews, published before April 2012. The evidence was classified, and consensus recommendations were given and graded according to the EFNS guidance regulations.ResultsStructural imaging, which should be performed at least once in the diagnostic work‐up of patients with cognitive impairment, serves to exclude other potentially treatable diseases, to recognize vascular lesions and to identify specific findings to help distinguish different forms of neurodegenerative types of dementia. Although typical cases of dementia may not benefit from routine functional imaging, these tools are recommended in those cases where diagnosis remains in doubt after clinical and structural imaging work‐up and in particular clinical settings. Amyloid imaging is likely to find clinical utility in several fields, including the stratification of patients with mild cognitive impairment into those with and without underlying AD and the evaluation of atypical AD presentations.ConclusionsA number of recommendations and good practice points are made to improve the diagnosis of AD and other dementias.
Steps to standardization and validation of hippocampal volumetry as a biomarker in clinical trials and diagnostic criterion for Alzheimer's disease
BackgroundThe promise of Alzheimer's disease biomarkers has led to their incorporation in new diagnostic criteria and in therapeutic trials; however, significant barriers exist to widespread use. Chief among these is the lack of internationally accepted standards for quantitative metrics. Hippocampal volumetry is the most widely studied quantitative magnetic resonance imaging measure in Alzheimer's disease and thus represents the most rational target for an initial effort at standardization.Methods and ResultsThe authors of this position paper propose a path toward this goal. The steps include the following: (1) Establish and empower an oversight board to manage and assess the effort, (2) adopt the standardized definition of anatomic hippocampal boundaries on magnetic resonance imaging arising from the European Alzheimer's Disease Centers–Alzheimer's Disease Neuroimaging Initiative hippocampal harmonization effort as a reference standard, (3) establish a scientifically appropriate, publicly available reference standard data set based on manual delineation of the hippocampus in an appropriate sample of subjects (Alzheimer's Disease Neuroimaging Initiative), and (4) define minimum technical and prognostic performance metrics for validation of new measurement techniques using the reference standard data set as a benchmark.ConclusionsAlthough manual delineation of the hippocampus is the best available reference standard, practical application of hippocampal volumetry will require automated methods. Our intent was to establish a mechanism for credentialing automated software applications to achieve internationally recognized accuracy and prognostic performance standards that lead to the systematic evaluation and then widespread acceptance and use of hippocampal volumetry. The standardization and assay validation process outlined for hippocampal volumetry was envisioned as a template that could be applied to other imaging biomarkers.