Objectives: Identifying patients’ advantageous radiotherapy modalities prior to CT simulation is challenging. This study aimed to develop a workflow using deep learning (DL)-predicted synthetic CT (sCT) for treatment modality comparison based solely on a diagnostic CT (dCT). Methods: A DL network, U-Net, was trained utilizing 46 thoracic cases from a public database to generate sCT images predicting planning CT (pCT) scans based on the latest dCT, and tested on 15 institutional patients. The sCT accuracy was evaluated against the corresponding pCT and a commercial algorithm deformed CT (MdCT) based on Mean Absolute Error (MAE) and Universal Quality Index (UQI). To determine advantageous treatment modality, clinical dose-volume histogram (DVH) metrics and Normal Tissue Complication Probability (NTCP) differences between proton and photon treatment plans were analyzed on the sCTs via concordance correlation coefficient (CCC). Results: The AI-generated sCTs closely resembled those of the commercial deformation algorithm in the tested cases. The differences in MAE and UQI values between the sCT-vs-pCT and MdCT-vs-pCT were 19.38 HU and 0.06, respectively. The mean absolute NTCP deviation between sCT and pCT was 1.54%, 0.21%, and 2.36% for esophagus perforation, lung pneumonitis, and heart pericarditis, respectively. The CCC between sCT and pCT was 0.90 for DVH metrics and 0.97 for NTCP, indicating moderate agreement for DVH metrics and substantial agreement. Conclusions: Radiation oncologists can potentially utilize this personalized sCT based approach as a clinical support tool to rapidly compare the treatment modality benefit during patient consultation and facilitate in-depth discussion on potential toxicities at a patient-specific level.
Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction
Abstract Background Inter‐fractional and intra‐fractional positioning and motion monitoring based on implanted fiducials through kilovoltage (kV) imaging is a cost‐effective approach to enhance intact prostate radiotherapy treatment accuracy. However, comprehensive studies for three‐dimensional (3D) position extraction and the corrective action threshold are lacking. Purpose To develop and verify a fiducial motion monitoring system with 3D position information based on triggered kV images taken during treatment delivery, and to comprehensively evaluate the recommended thresholds for corrective action during treatment. Methods An in‐house fiducial triangulation algorithm was developed to monitor fiducial positions using subsequent kV triggered images. The precision of fiducial triangulation and motion detection was validated on a pelvis phantom with four fiducial inserts. A retrospective study was conducted on prostate cancer patients who received either moderately hypofractionated radiotherapy (MHRT, n = 16) or stereotactic body radiotherapy (SBRT, n = 12), categorized by endo‐rectal balloon (ERB) use. Intra‐fractional positions relative to isocenter were computed, and these positions were analyzed in comparison to the original marker locations of the patient's treatment plan. A linear regression fit was used per fraction to determine correlation coefficients between motions in the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions. Average fraction time (AFT) of treatment was reported based on the observed average time spent on steps in the workflow and the percentage of fiducials caught outside of the current two‐dimensional (2D) tolerance threshold of 5 mm. The observed 3D offsets were used to estimate AFT for various 3D tolerance thresholds. Results Overall, our triangulation method proved to be very precise for static cases, where phantom measurements revealed a fiducial position triangulation precision of mm for stationary targets, but had a spread of mm for targets with 1 mm of motion. Employing triangulation, true motion exceeding 5 mm was detected above 4.0 mm in magnitude 90.9% of the time, a noticeable improvement in comparison to the 28%–65% successful detection rate reported by 2D projection methods. Most detection errors were attributed to depth disparity. Similar to other reports, correlation coefficients for intra‐fractional motion generally indicated no LR/SI, no LR/AP, and weak positive SI/AP correlations for MHRT and SBRT patients. Offsets beyond a 3D tolerance threshold of 5 mm were observed at a rate of 4.25%–5.25%, while the 5 mm 2D out‐of‐tolerance catch‐rate was 1.6%. The AFT was 8.1–8.2 min using the 2D tolerance threshold of 5 mm. In comparison, the estimated AFT for the proposed 3D tolerance monitoring of offsets beyond 2–5 mm was slightly higher at 8.2–10.9 min due to the higher amount of out‐of‐tolerance instances for the higher precision intra‐fractional motion management. Conclusions Our study showcases a promising subsequent kV‐based triangulation method for intra‐fractional prostate motion monitoring. Acquiring 3D motion information results in higher out‐of‐tolerance catch‐rates particularly in the depth dimension of the kV images, which is perpendicular to the treatment beam. Failure to properly observe and catch these offsets would result in sub‐optimal conformality and accuracy of the dose delivery.
Development of an automated CBCT‐based simulation‐free platform for expedited palliative radiotherapy on a conventional linear accelerator
AbstractBackgroundConventional approaches for emergent or expedited palliative radiotherapy (RT) involve the application of cumbersome vendor‐provided solutions and/or multiple patient appointments to complete the RT workflow within a compressed timeframe.PurposeThis report delineates the clinical development of an in‐house, semi‐automated Cone‐beam computed tomography (CBCT)‐based simulation‐free platform for expedited palliative RT on conventional linacs, intended to supplant existing techniques employed at this institution.MethodsThe internal software, termed SimFree Wizard (SFW), was engineered utilizing a C#‐based application programming interface integrated within the treatment planning system (TPS). Generated scripts were compiled as stand‐alone executables, with a graphical user interface (GUI) customized via an integrated development environment. The platform was conceived as a framework for accelerated CBCT‐based RT, bypassing the requirement for standard simulation imaging. SFW employs full automation where feasible to minimize user intervention, supplemented by graphical instructions for tasks requiring manual execution. During development, relevant temporal metrics from 10 end‐to‐end tests for palliative spine RT were quantified. User feedback was solicited via a simple questionnaire assessing the overall platform usability. Automated in‐house secondary verification software was developed for validation of the TPS‐calculated monitor units (MUs).ResultsThe mean duration for workflow execution was 41:42 ± 3:18 [mm:ss] (range ∼37–46 min). SFW satisfactorily generated simple, multi‐field CBCT‐based 3D treatment plans within seconds following delineation of the desired treatment area. User feedback indicated enhanced usability compared to previously employed solutions. Validation of the secondary verification software demonstrated accurate results for palliative spine RT and other simple cases wherein the dose calculation point resides in a predominantly homogenous medium.ConclusionA novel in‐house solution for expedited CBCT‐based RT was successfully developed, facilitating completion of the entire workflow within approximately 1‐hour or less for simple palliative/emergent scenarios. Overall, this application is expected to improve the quality and safety of palliative RT while greatly reducing workflow duration, thereby improving access to palliative care.
Comprehensive clinical implementation, workflow, and FMEA of bespoke silicone bolus cast from 3D printed molds using open‐source resources
AbstractBackgroundBolus materials have been used for decades in radiotherapy. Most frequently, these materials are utilized to bring dose closer to the skin surface to cover superficial targets optimally. While cavity filling, such as nasal cavities, is desirable, traditional commercial bolus is lacking, requiring other solutions. Recently, investigators have worked on utilizing 3D printing technology, including commercially available solutions, which can overcome some challenges with traditional bolus.PurposeTo utilize failure modes and effects analysis (FMEA) to successfully implement a comprehensive 3D printed bolus solution to replace commercial bolus in our clinic using a series of open‐source (or free) software products.Methods3D printed molds for bespoke bolus were created by exporting the DICOM structures of the bolus designed in the treatment planning system and manipulated to create a multipart mold for 3D printing. A silicone (Ecoflex 00–30) mixture is poured into the mold and cured to form the bolus. Molds for sheet bolus of five thicknesses were also created. A comprehensive FMEA was performed to guide workflow adjustments and QA steps.ResultsThe process map identified 39 and 30 distinct steps for the bespoke and flat sheet bolus workflows, respectively. The corresponding FMEA highlighted 119 and 86 failure modes, with 69 shared between the processes. Misunderstanding of plan intent was a potential cause for most of the highest‐scoring failure modes, indicating that physics and dosimetry involvement early in the process is paramount.ConclusionFMEA informed the design and implementation of QA steps to guarantee a safe and high‐quality comprehensive implementation of silicone bolus from 3D printed molds. This approach allows for greater adaptability not afforded by traditional bolus, as well as potential dissemination to other clinics due to the open‐source nature of the workflow.
Evaluation of knowledge‐based planning models for male pelvic CBCT‐based online adaptive radiotherapy on conventional linear accelerators
AbstractPurposeTo assess the practicality of employing a commercial knowledge‐based planning tool (RapidPlan) to generate adapted intact prostate and prostate bed volumetric modulated arc therapy (VMAT) plans on iterative cone‐beam computed tomography (iCBCT) datasets.Methods and materialsIntact prostate and prostate bed RapidPlan models were trained utilizing planning data from 50 and 44 clinical cases, respectively. To ensure that refined models were capable of producing adequate clinical plans with a single optimization, models were tested with 50 clinical planning CT datasets by comparing dose‐volume histogram (DVH) and plan quality metric (PQM) values between clinical and RapidPlan‐generated plans. The RapidPlan tool was then used to retrospectively generate adapted VMAT plans on daily iCBCT images for 20 intact prostate and 15 prostate bed cases. As before, DVH and PQM metrics were utilized to dosimetrically compare scheduled (iCBCT Verify) and adapted (iCBCT RapidPlan) plans. Timing data was collected to further evaluate the feasibility of integrating this approach within an online adaptive radiotherapy workflow.ResultsModel testing results confirmed the models were capable of producing VMAT plans within a single optimization that were overall improved upon or dosimetrically comparable to original clinical plans. Direct application of RapidPlan on iCBCT datasets produced satisfactory intact prostate and prostate bed plans with generally improved target volume coverage/conformality and rectal sparing relative to iCBCT Verify plans as indicated by DVH values, though bladder metrics were marginally increased on average. Average PQM values for iCBCT RapidPlans were significantly improved compared to iCBCT Verify plans. The average time required [in mm:ss] to generate adapted plans was 06:09 ± 02:06 (intact) and 07:12 ± 01:04 (bed).ConclusionThis study demonstrated the feasibility of leveraging RapidPlan to expeditiously generate adapted VMAT intact prostate and prostate bed plans on iCBCT datasets. In general, adapted plans were dosimetrically improved relative to scheduled plans, emphasizing the practicality of the proposed approach.