Abstract Background Quality assurance (QA) in radiation therapy is a critical component of ensuring accurate and consistent patient treatments, but many tasks are time consuming and rely on human visual acuity, which limits their accuracy. Purpose We aimed to automate monthly mechanical QA tests, improve measurement accuracy and precision, and decrease inter‐user variability using a computer vision‐based quality assurance (CVQA) system. Methods A custom marker board incorporating four ArUco markers was created along with a custom camera holder that mounted onto the gantry head. OpenCV was utilized to automate tests for couch translation, collimator and table angles, collimator and table walkout, optical distance indicator (ODI), and field size detection. A GUI was created to guide users through the tests, determine passing status of measurements based on MPPG8.b criteria, and display image captures to allow users to troubleshoot if needed. Reproducibility tests were taken across four days. The system was tested against manual measurements by graph paper or digital level for each test. Field sizes and ODI were read by 12 different physicists to determine human variability and comparisons for CVQA. Results The CVQA system took 5 min to set up and 7 min to perform all tests. All field sizes, collimator/table angles, collimator/table walkout, and table translations were reproducible within 0.5 mm and 0.5°. ODI measurements were reproducible within 1 mm. Table travel, ODI, and walkout measurements agreed with manual measurements within 0.5 mm and 0.4°, except for vertical table motions that agreed within 0.9 mm due to the lens focus being optimized for the 100 cm SSD plane. The standard deviation between physicists for almost all symmetric and asymmetric jaws was larger than the reproducibility of CVQA. CVQA has been utilized for five years and has demonstrated ability to identify mechanical machine issues. Conclusions CVQA successfully automates mechanical QA tasks, providing an efficient and precise system. CVQA is open source and freely available for academic institutions. Its adoption can improve workflow efficiency and consistency in clinical environments.
Comprehensive clinical implementation, workflow, and FMEA of bespoke silicone bolus cast from 3D printed molds using open‐source resources
AbstractBackgroundBolus materials have been used for decades in radiotherapy. Most frequently, these materials are utilized to bring dose closer to the skin surface to cover superficial targets optimally. While cavity filling, such as nasal cavities, is desirable, traditional commercial bolus is lacking, requiring other solutions. Recently, investigators have worked on utilizing 3D printing technology, including commercially available solutions, which can overcome some challenges with traditional bolus.PurposeTo utilize failure modes and effects analysis (FMEA) to successfully implement a comprehensive 3D printed bolus solution to replace commercial bolus in our clinic using a series of open‐source (or free) software products.Methods3D printed molds for bespoke bolus were created by exporting the DICOM structures of the bolus designed in the treatment planning system and manipulated to create a multipart mold for 3D printing. A silicone (Ecoflex 00–30) mixture is poured into the mold and cured to form the bolus. Molds for sheet bolus of five thicknesses were also created. A comprehensive FMEA was performed to guide workflow adjustments and QA steps.ResultsThe process map identified 39 and 30 distinct steps for the bespoke and flat sheet bolus workflows, respectively. The corresponding FMEA highlighted 119 and 86 failure modes, with 69 shared between the processes. Misunderstanding of plan intent was a potential cause for most of the highest‐scoring failure modes, indicating that physics and dosimetry involvement early in the process is paramount.ConclusionFMEA informed the design and implementation of QA steps to guarantee a safe and high‐quality comprehensive implementation of silicone bolus from 3D printed molds. This approach allows for greater adaptability not afforded by traditional bolus, as well as potential dissemination to other clinics due to the open‐source nature of the workflow.