Four‐year experience with an in‐house treatment management platform to streamline departmental operations in radiation oncology
Chang, G., Rong, Yi , Buckey, Courtney, Susen, Matthew, Lara, Pedro R., Lemish, Pamela R., Boutis, Gregory S., Chen, Quan, Chang, Grace N , Susen, Matthew J, Clouser, Edward L, Rong, Yi , Buckey, C, Lara, Pedro, Clouser, Edward

Journal of Applied Clinical Medical Physics | March 9, 2026 | Volume: 27 | Issue: 3 | Pages: No page available

10.1002/acm2.70515 Get It

Abstract Purpose To develop and implement an in‑house treatment‑management platform to improve communication, data accessibility, and task tracking across a radiation oncology department. Methods We developed Capsule, a custom software platform that centralizes patient data from the ARIA oncology information system (Varian Medical Systems, Palo Alto, United States), and integrates it with data from Outlook (Microsoft, Redmond, United States), spreadsheets, and manual inputs. Built using C#, SQL, and the .NET framework, it features a graphical interface in XAML with twelve modular tools to support workflows across a large multi‐modality department. A formal validation, feedback, and maintenance cycle was established. Its impact on workflow efficiency was evaluated using average CarePath task duration before and after implementation, supplemented by user interviews and surveys. Results The Department Schedule, Treatment Planning and On‐Treatment Whiteboard, Spreadsheet, and various workload tracking modules emerged as the most frequently used among dosimetrists surveyed.The Whiteboard module consolidates planning metadata for streamlined workflows. Workload and scheduling modules help distribute tasks fairly. The Department Schedule module centralizes daily role and contact information. The Spreadsheet module allows dosimetrists to identify a reference for unique plans and provides secure access to large exportable tabulated patient data and clinical trends. Other modules support proton down‐time replanning and special procedure physics assignment. One year after Capsule's implementation, most tasks in the external beam radiation therapy workflow experienced a reduction in average duration. Discussion Capsule streamlines workflows by integrating multiple tools into a single platform, supporting urgent scenarios, and improving task hand‐off. Its modular design allows customization to local workflows, but implementation must be guided by institutional oversight and formal quality management to ensure data security and compliance. Conclusion Capsule can provide a solution for improved workflow efficiency, communication, and interdisciplinary coordination. By democratizing access to routine and retrospective data, it supports treatment planning, scheduling, and quality improvement. Ongoing updates are essential as clinical practices evolve.
Development of a hybrid automated chart checking, data collection, and analysis system
Clouser, Edward , Chen, Quan , Harrington, Daniel P. , Rong, Yi , Buckey, C, Clouser, Edward L, Buckey, Courtney R, Rong, Yi , Clouser, Edward Lee

Journal of Applied Clinical Medical Physics | July 14, 2025 | Volume: 26 | Issue: 7 | Pages: No page available

10.1002/acm2.70161 Get It

Abstract Purpose To describe the creation and clinical deployment of an integrated stand‐alone hybrid automated chart review platform that is comprised of a database, oncology information system (OIS) interfaces, and a user interface (UI). Methods A consensus checklist was developed to homogenize the practices of clinical physics staff and physics residents for all plan types. Critical review of the single checklist's items led to the creation of a new concept, the “plan attribute,” which permits specialization of the final checklist based on the characteristics of a particular plan. Only relevant and applicable tests are automatically populated to form a plan checklist based on plan attributes. Each populated checklist in this hybrid automation platform includes elements of full automation, steps or functions that use automation to augment a human input or effort, as well as steps completed by humans. Logging and categorizing of deficiencies found during the chart check was also implemented. Results Chart check data was analyzed for an over 4‐year time span starting from the clinical deployment of the tool in October 2020. This analysis included a total of 427 073 tests spread among 7882 initial chart checks. The recorded deficiencies at three triage levels showed 7116 minor errors, 679 major errors, and 71 plan rejections. The plan rejection level is the highest chart deficiency, which required the plan to be rejected and sent back for serious remediation and/or new plan generation. Conclusion This report describes the successful development and implementation of a hybrid‐automated chart checking program. The software leverages modern database and software design to improve the per case performance and experience of a multi‐user group. Chart check database permits high‐level review and improvement in all aspects of plan check and user performance.
Development of an automated CBCT‐based simulation‐free platform for expedited palliative radiotherapy on a conventional linear accelerator
Tegtmeier, Riley C. , Clouser, Edward , Chen, Quan , Buckey, C, Chungbin, Suzanne J., Kutyreff, Christopher J. , Labbe, Amber L., Horning, Brooke L., Rule, William G., Vora, Sujay A., Chen, Quan , Clouser, Edward L, Buckey, Courtney R, Aguilar, Jose S, Rong, Yi , Kutyreff, Christopher J , Clouser, Edward Lee , Aguilar, Jose S., Labbe, Amber L., Rong, Yi

Journal of Applied Clinical Medical Physics | December 23, 2024 | Volume: 26 | Issue: 4 | Pages: No page available

10.1002/acm2.14612 Get It

AbstractBackgroundConventional approaches for emergent or expedited palliative radiotherapy (RT) involve the application of cumbersome vendor‐provided solutions and/or multiple patient appointments to complete the RT workflow within a compressed timeframe.PurposeThis report delineates the clinical development of an in‐house, semi‐automated Cone‐beam computed tomography (CBCT)‐based simulation‐free platform for expedited palliative RT on conventional linacs, intended to supplant existing techniques employed at this institution.MethodsThe internal software, termed SimFree Wizard (SFW), was engineered utilizing a C#‐based application programming interface integrated within the treatment planning system (TPS). Generated scripts were compiled as stand‐alone executables, with a graphical user interface (GUI) customized via an integrated development environment. The platform was conceived as a framework for accelerated CBCT‐based RT, bypassing the requirement for standard simulation imaging. SFW employs full automation where feasible to minimize user intervention, supplemented by graphical instructions for tasks requiring manual execution. During development, relevant temporal metrics from 10 end‐to‐end tests for palliative spine RT were quantified. User feedback was solicited via a simple questionnaire assessing the overall platform usability. Automated in‐house secondary verification software was developed for validation of the TPS‐calculated monitor units (MUs).ResultsThe mean duration for workflow execution was 41:42 ± 3:18 [mm:ss] (range ∼37–46 min). SFW satisfactorily generated simple, multi‐field CBCT‐based 3D treatment plans within seconds following delineation of the desired treatment area. User feedback indicated enhanced usability compared to previously employed solutions. Validation of the secondary verification software demonstrated accurate results for palliative spine RT and other simple cases wherein the dose calculation point resides in a predominantly homogenous medium.ConclusionA novel in‐house solution for expedited CBCT‐based RT was successfully developed, facilitating completion of the entire workflow within approximately 1‐hour or less for simple palliative/emergent scenarios. Overall, this application is expected to improve the quality and safety of palliative RT while greatly reducing workflow duration, thereby improving access to palliative care.
Comprehensive clinical implementation, workflow, and FMEA of bespoke silicone bolus cast from 3D printed molds using open‐source resources
Hobbis, Dean , Armstrong, Michael D., Patel, Samir H. , Tegtmeier, Riley C. , Chitsazzadeh, S. , Clouser, Edward , Smetanick, Jennifer L., Pettit, Justin, Gagneur, Justin D., Stoker, J. , Buckey, C, Laughlin, Brady S. , Chitsazzadeh, Shadi, Clouser, Edward L, Stoker, Joshua B., Rong, Yi , Buckey, Courtney R, Clouser, Edward Lee , Pettit, Justin, Rong, Yi

Journal of Applied Clinical Medical Physics | August 27, 2024 | Volume: 25 | Issue: 11 | Pages: No page available

10.1002/acm2.14498 Get It

AbstractBackgroundBolus materials have been used for decades in radiotherapy. Most frequently, these materials are utilized to bring dose closer to the skin surface to cover superficial targets optimally. While cavity filling, such as nasal cavities, is desirable, traditional commercial bolus is lacking, requiring other solutions. Recently, investigators have worked on utilizing 3D printing technology, including commercially available solutions, which can overcome some challenges with traditional bolus.PurposeTo utilize failure modes and effects analysis (FMEA) to successfully implement a comprehensive 3D printed bolus solution to replace commercial bolus in our clinic using a series of open‐source (or free) software products.Methods3D printed molds for bespoke bolus were created by exporting the DICOM structures of the bolus designed in the treatment planning system and manipulated to create a multipart mold for 3D printing. A silicone (Ecoflex 00–30) mixture is poured into the mold and cured to form the bolus. Molds for sheet bolus of five thicknesses were also created. A comprehensive FMEA was performed to guide workflow adjustments and QA steps.ResultsThe process map identified 39 and 30 distinct steps for the bespoke and flat sheet bolus workflows, respectively. The corresponding FMEA highlighted 119 and 86 failure modes, with 69 shared between the processes. Misunderstanding of plan intent was a potential cause for most of the highest‐scoring failure modes, indicating that physics and dosimetry involvement early in the process is paramount.ConclusionFMEA informed the design and implementation of QA steps to guarantee a safe and high‐quality comprehensive implementation of silicone bolus from 3D printed molds. This approach allows for greater adaptability not afforded by traditional bolus, as well as potential dissemination to other clinics due to the open‐source nature of the workflow.
Evaluation of knowledge‐based planning models for male pelvic CBCT‐based online adaptive radiotherapy on conventional linear accelerators
Tegtmeier, Riley C. , Clouser, Edward , Toesca, Diego A.S. , Flakus, Mattison J. , Bashir, Sara, Kutyreff, Christopher J. , Hobbis, Dean , Harrington, Daniel P. , Smetanick, Jennifer L., Yu, Nathan Y. , Vargas, Carlos , James, Sarah E. , Rwigema, Jean‐Claude M. , Clouser, Edward L, Laughlin, Brady S. , Santos Toesca, Diego A, Hobbis, Dean , Rong, Yi , Kutyreff, Christopher J , Clouser, Edward Lee , Rong, Yi

Journal of Applied Clinical Medical Physics | July 20, 2024 | Volume: 25 | Issue: 9 | Pages: No page available

10.1002/acm2.14464 Get It

AbstractPurposeTo assess the practicality of employing a commercial knowledge‐based planning tool (RapidPlan) to generate adapted intact prostate and prostate bed volumetric modulated arc therapy (VMAT) plans on iterative cone‐beam computed tomography (iCBCT) datasets.Methods and materialsIntact prostate and prostate bed RapidPlan models were trained utilizing planning data from 50 and 44 clinical cases, respectively. To ensure that refined models were capable of producing adequate clinical plans with a single optimization, models were tested with 50 clinical planning CT datasets by comparing dose‐volume histogram (DVH) and plan quality metric (PQM) values between clinical and RapidPlan‐generated plans. The RapidPlan tool was then used to retrospectively generate adapted VMAT plans on daily iCBCT images for 20 intact prostate and 15 prostate bed cases. As before, DVH and PQM metrics were utilized to dosimetrically compare scheduled (iCBCT Verify) and adapted (iCBCT RapidPlan) plans. Timing data was collected to further evaluate the feasibility of integrating this approach within an online adaptive radiotherapy workflow.ResultsModel testing results confirmed the models were capable of producing VMAT plans within a single optimization that were overall improved upon or dosimetrically comparable to original clinical plans. Direct application of RapidPlan on iCBCT datasets produced satisfactory intact prostate and prostate bed plans with generally improved target volume coverage/conformality and rectal sparing relative to iCBCT Verify plans as indicated by DVH values, though bladder metrics were marginally increased on average. Average PQM values for iCBCT RapidPlans were significantly improved compared to iCBCT Verify plans. The average time required [in mm:ss] to generate adapted plans was 06:09 ± 02:06 (intact) and 07:12 ± 01:04 (bed).ConclusionThis study demonstrated the feasibility of leveraging RapidPlan to expeditiously generate adapted VMAT intact prostate and prostate bed plans on iCBCT datasets. In general, adapted plans were dosimetrically improved relative to scheduled plans, emphasizing the practicality of the proposed approach.
Computer automation for physics chart check should be adopted in clinic to replace manual chart checking for radiotherapy
Clouser, Edward , Chen, Quan , Rong, Yi , Clouser, Edward L, Rong, Yi , Clouser, Edward Lee

Journal of Applied Clinical Medical Physics | February 5, 2021 | Volume: 22 | Issue: 2 | Pages: 4-8

10.1002/acm2.13177 Get It