Background: Patients with cardiac implantable electronic devices (CIEDs) undergoing radiation therapy face potential risks of device malfunction. Proton beam therapy (PBT), with its reduced neutron scatter, has emerged as a potentially safer alternative, yet real-world safety data remain scarce. Methods: We conducted a retrospective cohort study of 100 patients with CIEDs (76 pacemakers, 24 ICDs) who underwent PBT from 2016 to 2023 at a quaternary center. Baseline and serial device interrogations were performed before, during, and after treatment to assess lead impedance, capture thresholds, battery function, and arrhythmic events. Patients were stratified by pacemaker dependence and monitored accordingly. Primary outcomes included device malfunction and new-onset arrhythmias during treatment. Secondary outcomes included device parameter changes, one-year arrhythmia incidence, and cardiac-related hospitalizations. Results: No treatment-related deaths or major device failures occurred. Device malfunction was rare (2 pacemaker patients, 2.6%), with no malfunctions in ICD recipients. Transient, non-clinically significant changes in lead impedance and capture thresholds were observed. Arrhythmias during treatment occurred in 26% of pacemaker and 25% of ICD patients, but only 4% developed new arrhythmias. At one year, device-related complications and cardiac outcomes remained comparable across groups. Independent predictors of arrhythmias during treatment included a higher radiation dose per fraction (OR 1.45; p=0.001), a longer treatment duration (OR 1.12; p=0.04), and a higher number of fractions (OR 1.20; p=0.01). Conclusion: Proton beam therapy appears safe in patients with CIEDs, with a low incidence of clinically significant device malfunctions or arrhythmias. These findings support the integration of PBT into routine practice for this population and underscore the importance of structured monitoring protocols and prospective guideline refinement.
Development of a hybrid automated chart checking, data collection, and analysis system
Abstract Purpose To describe the creation and clinical deployment of an integrated stand‐alone hybrid automated chart review platform that is comprised of a database, oncology information system (OIS) interfaces, and a user interface (UI). Methods A consensus checklist was developed to homogenize the practices of clinical physics staff and physics residents for all plan types. Critical review of the single checklist's items led to the creation of a new concept, the “plan attribute,” which permits specialization of the final checklist based on the characteristics of a particular plan. Only relevant and applicable tests are automatically populated to form a plan checklist based on plan attributes. Each populated checklist in this hybrid automation platform includes elements of full automation, steps or functions that use automation to augment a human input or effort, as well as steps completed by humans. Logging and categorizing of deficiencies found during the chart check was also implemented. Results Chart check data was analyzed for an over 4‐year time span starting from the clinical deployment of the tool in October 2020. This analysis included a total of 427 073 tests spread among 7882 initial chart checks. The recorded deficiencies at three triage levels showed 7116 minor errors, 679 major errors, and 71 plan rejections. The plan rejection level is the highest chart deficiency, which required the plan to be rejected and sent back for serious remediation and/or new plan generation. Conclusion This report describes the successful development and implementation of a hybrid‐automated chart checking program. The software leverages modern database and software design to improve the per case performance and experience of a multi‐user group. Chart check database permits high‐level review and improvement in all aspects of plan check and user performance.
Evaluation of knowledge‐based planning models for male pelvic CBCT‐based online adaptive radiotherapy on conventional linear accelerators
AbstractPurposeTo assess the practicality of employing a commercial knowledge‐based planning tool (RapidPlan) to generate adapted intact prostate and prostate bed volumetric modulated arc therapy (VMAT) plans on iterative cone‐beam computed tomography (iCBCT) datasets.Methods and materialsIntact prostate and prostate bed RapidPlan models were trained utilizing planning data from 50 and 44 clinical cases, respectively. To ensure that refined models were capable of producing adequate clinical plans with a single optimization, models were tested with 50 clinical planning CT datasets by comparing dose‐volume histogram (DVH) and plan quality metric (PQM) values between clinical and RapidPlan‐generated plans. The RapidPlan tool was then used to retrospectively generate adapted VMAT plans on daily iCBCT images for 20 intact prostate and 15 prostate bed cases. As before, DVH and PQM metrics were utilized to dosimetrically compare scheduled (iCBCT Verify) and adapted (iCBCT RapidPlan) plans. Timing data was collected to further evaluate the feasibility of integrating this approach within an online adaptive radiotherapy workflow.ResultsModel testing results confirmed the models were capable of producing VMAT plans within a single optimization that were overall improved upon or dosimetrically comparable to original clinical plans. Direct application of RapidPlan on iCBCT datasets produced satisfactory intact prostate and prostate bed plans with generally improved target volume coverage/conformality and rectal sparing relative to iCBCT Verify plans as indicated by DVH values, though bladder metrics were marginally increased on average. Average PQM values for iCBCT RapidPlans were significantly improved compared to iCBCT Verify plans. The average time required [in mm:ss] to generate adapted plans was 06:09 ± 02:06 (intact) and 07:12 ± 01:04 (bed).ConclusionThis study demonstrated the feasibility of leveraging RapidPlan to expeditiously generate adapted VMAT intact prostate and prostate bed plans on iCBCT datasets. In general, adapted plans were dosimetrically improved relative to scheduled plans, emphasizing the practicality of the proposed approach.
Technical note: Characterization of novel iterative reconstructed cone beam CT images for dose tracking and adaptive radiotherapy on L‐shape linacs
AbstractBackgroundCone‐beam computed tomography (CBCT) allows for patient setup and positioning, and potentially dose verification or adaptive replanning prior to each treatment delivery. Poor CBCT image quality due to scatter artifacts and patient motion has been a major limiting factor. A new image reconstruction algorithm was recently clinically implemented for improving image quality through iterative reconstruction (iCBCT).PurposeThis study aims to characterize iCBCT image quality, establish image value (HU)‐to‐relative electron density (RED) calibration curves for dose calculation, and assess the dosimetric accuracy for different anatomical sites.Material and methodsBoth conventional CBCT and iCBCT scans were acquired from a Varian TrueBeam On‐Board Imager system. A Catphan 604 phantom was scanned to compare image quality between the traditional Feldkamp–Davis–Kress (FDK) and novel iterative reconstruction techniques. Computerized Imaging Reference Systems (CIRS) electron density phantom was used to construct site‐specific HU‐RED curves corresponding to various scan settings. The CIRS Dynamic Thorax phantom, Rando pelvis phantom, and BrainLab head phantom were used for assessing dosimetric accuracy calculated on iCBCT images, compared to that on traditional FDK‐based CBCT images. All phantoms were scanned on a computed tomography (CT) to obtain baseline HU values for comparison.ResultsTest results obtained from Catphan showed statistically significant improvement with iCBCT, compared to FDK CBCT. Average HU differences from the baseline CT values were improved to within ±30 HU for iCBCT, compared to FDK CBCT for phantom studies. Dose calculated on iCBCT for both phantoms and patient cases directly using baseline HU‐RED calibration from CT showed 0.5%–2.0% accuracy from the baseline dose calculated on CT, which is comparable to doses calculated using site‐specific HU‐RED calibration curves.ConclusioniCBCT provides improved image quality, improved HU accuracy compared to CT baseline, and has potential to provide online dose verification as part of the adaptive radiotherapy workflow directly using the baseline HU‐RED calibration curve from CT.
Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer
AbstractThis work is to show which is more relevant to cause local failures (LFs) due to patient setup uncertainty between the planning target volume (PTV) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (H&N) cancer treated with volumetric‐modulated arc therapy (VMAT). Thirteen LFs in 10 H&N patients treated by VMAT were analyzed. Measures have been taken to minimize the chances of insufficient target delineation for these patients and the patients were clinically determined to have LF based on the PET/CT scan results by an experienced radiologist and then reviewed by a second experienced radiation oncologist. Two methods were used to identify the possible locations of LF due to underdosage: (a) examining the standard VMAT plan, in which the underdosed volume in the nominal dose distribution (UVN) was generated by subtracting the volumes receiving the prescription doses from PTVs, and (b) plan robustness analysis, in which in addition to the nominal dose distribution, six perturbed dose distributions were created by translating the CT iso‐center in three cardinal directions by the PTV margin. The coldest dose distribution was represented by the minimum of the seven doses in each voxel. The underdosed volume in the coldest dose distribution (UVC) was generated by subtracting the volumes receiving the prescription doses in the coldest dose distribution from the volumes receiving the prescription doses in the nominal dose distribution. UVN and UVC were subsequently examined for spatial association with the locations of LF. The association was tested using the binominal distribution and the Fisher's exact test of independence. We found that of 13 LFs, 11 were associated with UVCs (P = 0.011), while three were associated with UVNs (P = 0.99). We concluded that the possible target underdosage due to patient setup uncertainties appeared to be a more relevant factor associated with LF in VMAT for H&N cancer than the compromised PTV coverage at least for the patients included in this study.