Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction
Gevorkyan, Gevork S., Chen, Quan , Tegtmeier, Riley C. , Toesca, Diego Santos, Laughlin, Brady, Bashir, Sara, Welchel, Zachary James, Vargas, Carlos , Rwigema, Jean‐Claude M. , James, Sarah E. , Yu, Nathan Y. , Chen, Quan , Laughlin, Brady S. , Toesca, Diego A.S. , Gevorkyan, Gevork S. , Holmes, Jason , Rong, Yi

Medical Physics | February 22, 2025 | Volume: 52 | Issue: 6 | Pages: 4008-4022

10.1002/mp.17703 Get It

Abstract Background Inter‐fractional and intra‐fractional positioning and motion monitoring based on implanted fiducials through kilovoltage (kV) imaging is a cost‐effective approach to enhance intact prostate radiotherapy treatment accuracy. However, comprehensive studies for three‐dimensional (3D) position extraction and the corrective action threshold are lacking. Purpose To develop and verify a fiducial motion monitoring system with 3D position information based on triggered kV images taken during treatment delivery, and to comprehensively evaluate the recommended thresholds for corrective action during treatment. Methods An in‐house fiducial triangulation algorithm was developed to monitor fiducial positions using subsequent kV triggered images. The precision of fiducial triangulation and motion detection was validated on a pelvis phantom with four fiducial inserts. A retrospective study was conducted on prostate cancer patients who received either moderately hypofractionated radiotherapy (MHRT, n = 16) or stereotactic body radiotherapy (SBRT, n = 12), categorized by endo‐rectal balloon (ERB) use. Intra‐fractional positions relative to isocenter were computed, and these positions were analyzed in comparison to the original marker locations of the patient's treatment plan. A linear regression fit was used per fraction to determine correlation coefficients between motions in the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions. Average fraction time (AFT) of treatment was reported based on the observed average time spent on steps in the workflow and the percentage of fiducials caught outside of the current two‐dimensional (2D) tolerance threshold of 5 mm. The observed 3D offsets were used to estimate AFT for various 3D tolerance thresholds. Results Overall, our triangulation method proved to be very precise for static cases, where phantom measurements revealed a fiducial position triangulation precision of mm for stationary targets, but had a spread of mm for targets with 1 mm of motion. Employing triangulation, true motion exceeding 5 mm was detected above 4.0 mm in magnitude 90.9% of the time, a noticeable improvement in comparison to the 28%–65% successful detection rate reported by 2D projection methods. Most detection errors were attributed to depth disparity. Similar to other reports, correlation coefficients for intra‐fractional motion generally indicated no LR/SI, no LR/AP, and weak positive SI/AP correlations for MHRT and SBRT patients. Offsets beyond a 3D tolerance threshold of 5 mm were observed at a rate of 4.25%–5.25%, while the 5 mm 2D out‐of‐tolerance catch‐rate was 1.6%. The AFT was 8.1–8.2 min using the 2D tolerance threshold of 5 mm. In comparison, the estimated AFT for the proposed 3D tolerance monitoring of offsets beyond 2–5 mm was slightly higher at 8.2–10.9 min due to the higher amount of out‐of‐tolerance instances for the higher precision intra‐fractional motion management. Conclusions Our study showcases a promising subsequent kV‐based triangulation method for intra‐fractional prostate motion monitoring. Acquiring 3D motion information results in higher out‐of‐tolerance catch‐rates particularly in the depth dimension of the kV images, which is perpendicular to the treatment beam. Failure to properly observe and catch these offsets would result in sub‐optimal conformality and accuracy of the dose delivery.
Clinical Practice Evolvement for Post-Operative Prostate Cancer Radiotherapy—Part 2: Feasibility of Margin Reduction for Fractionated Radiation Treatment with Advanced Image Guidance
Laughlin, Brady S. , Yu, Nathan Y. , Lo, Stephanie, Duan, Jingwei , Welchel, Zachary James, Tinnon, Katie, Beckett, Mason, Wong, William W. , Keole, Sameer R., Rwigema, Jean‐Claude M. , Vargas, Carlos , Welchel, Zachary, Schild, Steven E. , Duan, Jingwei , Laughlin, Brady S , Rong, Yi

Cancers | December 22, 2022 | Volume: 15 | Issue: 1 | Pages: 40

10.3390/cancers15010040 Get It

Purpose: Planning target volume (PTV) expansion for post-prostatectomy radiotherapy is typically ≥5 mm. Recent clinical trials have proved the feasibility of a reduced margin of 2–3 mm for treatments on MRI-linac. We aim to study the minimum PTV margin needed using iterative cone-beam CT (iCBCT) as image guidance on conventional linacs. Materials/Methods: Fourteen patients who received post-prostatectomy irradiation (8 with an endorectal balloon and 6 without a balloon) were included in this study. Treatment was delivered with volumetric modulated radiation therapy (VMAT). Fractional dose delivery was evaluated in 165 treatment fractions. The bladder, rectal wall, femoral heads, and prostate bed clinical tumor volume (CTV) were contoured and verified on daily iCBCT. PTV margins (0 mm, 2 mm, and 4 mm) were evaluated on daily iCBCT. CTV coverage and OAR dose parameters were assessed with each PTV margin. Results: CTV D100% was underdosed with a 0 mm margin in 32% of fractions in comparison with 2 mm (6%) and 4 mm (6%) PTV margin (p ≤ 0.001). CTV D95% > 95% was met in 93–94% fractions for all PTV expansions. CTV D95% > 95% was achieved in more patients with an endorectal balloon than those without: 0 mm—90/91 (99%) vs. 63/74 (85%); 2 mm—90/91 (99%) vs. 65/75 (87%); 4 mm—90/90 (100%) vs. 63/73 (86%). There was no difference in absolute median change in CTV D95% (0.32%) for 0-, 2-, and 4 mm margins. The maximum dose remained under 108% for 100% (0 mm), 97% (2 mm), and 98% (4 mm) of images. Rectal wall maximum dose remained under 108% for 100% (0 mm), 100% (2 mm), and 98% (4 mm) of images. Conclusions: With high-quality iCBCT image guidance, PTV margin accounting for inter-fractional uncertainties can be safely reduced for post-prostatectomy radiotherapy. For fractionated radiotherapy, an isotropic expansion of 2 mm and 4 mm may be considered for margin expansion with and without the endorectal balloon. Future application for margin reduction needs to be further evaluated and considered with the advent of shorter post-prostatectomy radiation courses.