Back to Authors

Cortese, Jonathan

https://orcid.org/0000-0002-1616-9113

Mayo Clinic

Bicêtre Hospital

Citations 22

Measuring artery diameter in rabbit angiograms for neurovascular disease modeling applications and device testing
Khan, YM , Franklin, J Ford, Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Khan, Yasmine , Franklin, Jack , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yong-Hong , Lortscher, Sarah , Brinjikji, Waleed , Kadirvel, Ram , Kallmes, David F , Cortese, Jonathan

Interventional Neuroradiology | June 10, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251347398 Get It

Background and purpose New Zealand White Rabbits are a useful preclinical model for neurovascular research. Inducing right common carotid artery aneurysms in New Zealand White Rabbits gives researchers the ability to test neurovascular devices in vivo. This study takes advantage of archived angiograms to obtain vascular measurements of interest for future research in rabbit models. Methods Rabbit angiograms from endovascular studies conducted in-house between 2005 and 2024 were analyzed using ImageJ at points of interest along the thoracic and abdominal aorta. Using scale references, the diameters of various New Zealand White Rabbit (2.5–3.5 kg) arteries were measured for aneurysm models and controls. Anatomic vascular variations were categorized and recorded. Results Measurable artery diameters at 39 points of interest were recorded for 170 female New Zealand White Rabbits. Type 1 vascular anatomy was the most common rabbit aortic arch, characterizing 85% of identifiable rabbit anatomies in this study. Conclusion By making these measurements available, this study simplifies future neurovascular studies, allowing for vasculature to be selected by size depending on the application. Additionally, the study offers insight into the relationship between elastase-induced aneurysms and surrounding vasculature size and draws size comparisons between some key arteries of interest.
Impact of aspiration catheter inner diameter on first-pass effect: A systematic review and meta-analysis
Jazayeri, Seyed Behnam , Cortese, Jonathan , Reda, Abdelrahman, Maroufi, Seyed Farzad , Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F. , Cortese, Jonathan , Maroufi, Seyed Farzad , Ghozy, Sherief , Kadirvel, Ram , Kallmes, David F , Reda, Abdullah , Reda, Abdelrahman

Interventional Neuroradiology | June 10, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251345637 Get It

Background The first-pass effect (FPE) refers to the complete or near-complete revascularization with a single pass of mechanical thrombectomy devices. While previous claims suggest a link between larger catheters and the effectiveness of contact aspiration (CA) thrombectomy, no extensive research has confirmed if larger distal inner diameter (ID) catheters achieve higher FPE rates. Methods We searched PubMed, Scopus, and Web of Science to assess the impact of aspiration catheter distal ID size on FPE. The primary outcome was FPE rate, defined as thrombolysis in cerebral ischemia (TICI) grades 2c-3 at first pass, and the secondary outcome was modified FPE (TICI 2b-3 in a single pass). Aspiration catheters were categorized based on distal ID: 0.060–0.069 (medium bore), 0.070–0.074 (large bore), and greater than 0.074 inches (super-large bore). Rates of FPE were pooled using random effect models and compared using a Chi-square test. Results Our study included 34 articles with 4831 patients. FPE rates were 27.7% (95% CI, 15.1–45.3) for medium bore, 46.6% (95% CI, 33.7–59.9) for large, and 58.3% (95% CI, 44.8–70.7) for super-large catheters. The FPE rate was significantly higher for super-large bore catheters compared with other groups (χ² = 7.26, p = 0.03). A similar trend was observed for modified FPE rates, which were 51.1% (95% CI, 45.3–56.8) for medium bore, 60.0% (95% CI, 52.8–66.8) for large bore, and 80% (95% CI, 56.3–94.2) for super-large bore catheters (χ² = 8.14, p = 0.03). Conclusion Our analysis indicates that larger CA catheters are correlated with higher FPE rates.
Abstract TP253: Can the clot meniscus and claw signs predict thrombectomy and clinical outcomes in stroke patients? A Systematic Review and Meta-Analysis
Gajjar, Aryan , Douri, Dani, Kallmes, David F. , Reda, Abdullah , Cortese, Jonathan , Ghozy, Sherief

Stroke | January 30, 2025 | Volume: 56 | Issue: Suppl_1 | Pages: No page available

10.1161/str.56.suppl_1.tp253 Get It

Background: Angiographic shape of occlusion, like the clot meniscus sign and the claw-sign, have been reported to potentially impact recanalization rate and clinical outcome in patient undergoing mechanical thrombectomy for acute ischemic strokes. Method: Following PRISMA guidelines, a systematic literature search was conducted across PubMed, Scopus, and Web of Science databases. Patients were grouped into clot meniscus/claw sign positive and negative groups based on the definitions obtained from each study. Primary outcomes included technical success, with a meta-analysis performed using a random-effects model to calculate proportions and odds ratios (OR) with 95% confidence intervals (Cl). Results: We included seven studies recruiting 1572 patients. The results indicated that the positive and negative groups had comparable first-pass effect (OR: 1.95; 95%CI: 0.76 – 5.01; P = 0.167) and final recanalization (OR: 1.36; 95%CI: 0.81 – 2.27; P = 0.248) rates. However, the rate of having a favorable functional outcome was significantly higher in the positive than negative sign groups (OR: 1.91; 95%CI: 1.25 – 2.92; P < 0.003). Within the sign-positive population, the use of contact aspiration was associated with a significantly higher rate of recanalization compared to using a stent retriever (OR: 0.18; 95%CI: 0.07 – 0.49; P < 0.001). This result did not translate into a clinical impact, as both stent retriever and contact aspiration showed comparable rates of functional independence at three months (OR: 0.22; 95%CI: 0.02 – 2.33; P = 0.210). Conclusion: The presence of the clot meniscus/claw sign is not associated with recanalization outcomes after thrombectomy. However, it might be a good sign to predict which thrombectomy technique might be associated with better recanalization, although current evidence might need further confirmation.
What can we learn from machine learning studies on flow diverter aneurysm embolization? A systematic review
Bayraktar, Esref Alperen , Cortese, Jonathan , Jabal, Mohamed Sobhi , Ghozy, Sherief , Orscelik, Atakan , Bilgin, Cem , Kadirvel, Ramanathan , Brinjikji, Waleed , Kallmes, David F, Ghozy, Sherief , Orscelik, Atakan , Cortese, Jonathan , Bayraktar, Esref Alperen , Kallmes, David F.

Journal of NeuroInterventional Surgery | December 18, 2024 | Volume: 17 | Issue: 11 | Pages: 1168-1173

10.1136/jnis-2024-022147 Get It

Background As the use of flow diverters has expanded in recent years, predicting successful outcomes has become more challenging for certain aneurysms. Objective To provide neurointerventionalists with an understanding of the available machine learning algorithms for predicting the success of flow diverters in occluding aneurysms. Methods This study followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, and the four major medical databases (PubMed, Embase, Scopus, Web of Science) were screened. The study included original research articles that evaluated the predictive abilities of various machine learning algorithms for determining the success of flow diverters in achieving aneurysm occlusion. Results Five studies out of 217 were included based on our criteria. The included studies used various variables (patient demographics, aneurysm and parent artery characteristics, flow diverter and hemodynamic-related features, and angiographic parametric imaging) to predict flow diverter treatment outcomes. The machine learning algorithms used, along with their respective accuracy rates, were as follows: logistic regression (61% and 85%), support vector machine (88%), Gaussian support vector machine (90%), linear support vector machine (85%), decision tree (80%), random forest (87%), k-nearest neighbors (83% and 85%), XGBoost (87%), CatBoost (86%), deep neural networks (77.9%), and recurrent neural networks (74%).Two studies trained the machine learning models with both all features and the most significant features. Both studies observed that the accuracy of machine learning models decreased by removing the insignificant features. Conclusion The current literature indicates that machine learning algorithms can be trained to predict the success of flow diverters with an accuracy of up to 90%.
Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis
Orscelik, Atakan , Bilgin, Cem , Cortese, Jonathan , Cayme, Joshua J , Şenol, Yiğit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Beizavi, Zahra , Brinjikji, Waleed , Kallmes, David F. , Senol, Yigit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Brinjikji, Waleed , Orscelik, Atakan , Cortese, Jonathan , Zandpazandi, Sara

Journal of NeuroInterventional Surgery | October 22, 2024 | Volume: 17 | Issue: 6 | Pages: 567-573

10.1136/jnis-2024-022381 Get It

Background The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems. Method We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024. The primary outcome was a favorable outcome defined as a modified Rankin Scale (mRS) score of 0–2 at 90 days after the procedure. Data were analyzed using a random-effects model and heterogeneity was assessed using the I2 test and Q statistics. Results Five studies with a total of 1562 patients were analyzed. Of these, 68.4% were treated with biplane systems and 31.6% with single plane systems. Single plane angiography was associated with a significantly higher rate of favorable outcomes (OR 1.43; 95% CI 1.13 to 1.80; P<0.01). There were no significant differences in successful recanalization, periprocedural complications, procedure time, total fluoroscopy time, or contrast volume between the two systems. Conclusion While single plane angiography systems may offer slightly better outcomes in MT for AIS, both systems appear equally effective in most clinical and technical perspectives, suggesting that system selection may be more dependent on availability and procedural requirements rather than inherent superiority. Our findings may encourage clinicians to use single-plane angiography in settings where the biplane angiography suite availability is limited, but it should be noted that this observation may have been influenced by selection bias, particularly since the larger studies included in our meta-analysis did not observe this effect in adjusted analyses for potential confounder factors.
Can the clot meniscus and claw signs predict thrombectomy and clinical outcomes in patients with stroke? A systematic review and meta-analysis
Cortese, Jonathan , Ghozy, Sherief , Gajjar, Aryan , Douri, Dani, Kadirvel, Ramanathan , Kallmes, David F. , Reda, Abdullah , Cortese, Jonathan , Ghozy, Sherief , Kadirvel, Ram , Reda, Abdullah

Journal of NeuroInterventional Surgery | October 11, 2024 | Volume: 17 | Issue: 9 | Pages: 932-938

10.1136/jnis-2024-022322 Get It

Background The angiographic shape of an occlusion, like the clot meniscus sign and the claw sign, has been reported to potentially impact the recanalization rate and clinical outcome in patients undergoing mechanical thrombectomy for acute ischemic strokes. Method Following PRISMA guidelines, a systematic literature search was conducted across PubMed, Scopus, Embase and Web of Science databases. Patients were grouped into clot meniscus/claw sign positive and negative groups based on the definitions obtained from each study. Primary outcomes included technical success, with a meta-analysis performed using a random-effects model to calculate proportions and odds ratios (OR) with 95% confidence intervals (Cl). Results We included seven studies recruiting 1572 patients. The results indicated that the positive and negative groups had comparable first-pass effect (OR 1.95; 95% CI 0.76 to 5.01; P=0.167) and final recanalization (OR 1.36; 95% CI 0.81 to 2.27; P=0.248) rates. However, the rate of having a favorable functional outcome was significantly higher in the positive group than in the negative sign group (OR 1.91; 95% CI 1.25 to 2.92; P<0.003). Within the sign-positive population, the use of contact aspiration was associated with a significantly higher rate of recanalization compared with using a stent retriever (OR 0.18; 95% CI 0.07 to 0.49; P<0.001). This result did not translate into a clinical impact, as both stent retriever and contact aspiration showed comparable rates of functional independence at 3 months (OR 0.22; 95% CI 0.02 to 2.33; P=0.210). Conclusion The presence of the clot meniscus/claw sign is not associated with recanalization outcomes after thrombectomy. However, it might be a good sign to predict which thrombectomy technique might be associated with better recanalization, although current evidence may need further confirmation.
Optimizing the hemodynamics of hand injections in neuroangiography
Bayraktar, Esref Alperen , Bilgin, Cem , Ueki, Yasuhito , Kadirvel, Ramanathan , Brinjikji, Waleed , Cloft, Harry J. , Kallmes, David F. , Bilgin, Cem , Kadirvel, Ram , Kallmes, David F , Bayraktar, Esref Alperen , Li, Jiahui , Cortese, Jonathan

Interventional Neuroradiology | September 23, 2024 | Volume: 30 | Issue: 6 | Pages: 833-838

10.1177/15910199241285944 Get It

Purpose Optimizing the preparation of a 10 ml syringe for manual injection of contrast media can help operators obtain easier and faster injections. This study aims to compare the flow rates of different contrast media injection methods. Methods Different contrast media solutions were compared: 100% contrast (10 ml contrast), mixed contrast solution (8:2 contrast/saline), and layered contrast below saline (“Parfait”) in different volumes. Contrast media were injected at room temperature (20°C) and after heating (37°C). Four operators injected 10 ml syringes filled with different mediums through 5-French angiographic catheters. The average flow rate was used to compare different contrast injection mediums. The Kruskal-Wallis test with post-hoc pairwise comparisons using Bonferroni correction or Mann-Whitney U-tests were employed depending on the type of comparison. Results Compared to the 100% contrast solution, every Parfait media and mixed contrast solution demonstrated significantly higher flow rates (p < 0.001). The 5 ml saline Parfait had the highest flow rate among the Parfait solutions. The 5 ml saline Parfait and the mixed solution had comparable flow rates (p = 0.237). Higher flow rates were observed upon heating both 100% contrast (p < 0.001) and mixed contrast solutions (p < 0.001) in comparison to their flow rates at room temperature. Conclusion This study demonstrates the capability of the Parfait and mixed contrast injections to achieve higher flow rates than the 100% contrast solutions. Heating the contrast media to 37°C also proves to be a viable strategy for further enhancing the flow rates for 100% and mixed contrast solutions.
Flow diverter braid deformation following treatment of cerebral aneurysms: incidence, clinical relevance, and potential risk factors
Popica, Dan Adrian , Cortese, Jonathan , Oliver, Alexander A , Plaforet, Vincent, Diaz, Ignacio Molina, Ikka, Léon , Mihalea, Cristian , Chalumeau, Vanessa , Kallmes, David F. , Caroff, Jildaz , Mihalea, Cristian , Chalumeau, Vanessa , Caroff, Jildaz , Spelle, Laurent , Cortese, Jonathan , Oliver, Alexander A , Rodriguez‐Erazú, Fernanda , Spelle, Laurent

Journal of NeuroInterventional Surgery | August 30, 2024 | Volume: 17 | Issue: 8 | Pages: 864-869

10.1136/jnis-2024-022236 Get It

Background Although flow diverters (FDs) have benefited from several technical improvements, recently concerns have arisen regarding the braid stability after implantation. Thus, we investigated frequency, predictive factors, and clinical impact of the phenomenon of FD braid deformation (FDBD). Methods Consecutive intracranial aneurysms (IAs) treated with various FDs, between January 2018 and July 2023, were reviewed to identify FDBD (defined as the deformation of a FD without any external force applied to it). Patient, aneurysm, procedural, and FD characteristics were retrieved and analyzed using univariate and multivariable analyses. Morbidity is defined as a score of +1 in the modified Rankin Scale at 3 months. Results In total, 245 FD procedures (271 FDs implanted; 25 multiple IAs treated with 1 FD) in 228 patients; FDBD was observed in 36/245 cases (14.7%), mainly at follow-up angiography (32/36, 88.9%); fish-mouthing was the most frequent FDBD. Morbidity was related to fish-mouthing and braid collapse and was significantly higher in the FDBD group after retreatment (p=0.04). Drawn filled tubing with platinum (DFT) (adjusted odds ratio (aOR)=7.0, 95% CI 3.0 to 17.5; p<0.001) and FD diameter (aOR=2.2, 95% CI 1.3 to 4.1; p<0.01) were identified as independent predictors of FDBD. The metal alloy composing the FD (p=0.13) and coated surfaces were not significantly associated with FDBD (p=0.54 in multivariable analysis). Conclusions FDBD is a frequent phenomenon observed in about 15% of cases, and it was responsible for higher morbidity. Only FD characteristics (DFT and FD diameter) were independent determinants of FDBD. Future research should focus on the impact of novel braid configurations and materials on braid stability.
Neck apposition is a key factor for aneurysm occlusion after Woven EndoBridge device embolization
Cortese, Jonathan , Juhász, J , Rodriguez‐Erazú, Fernanda , Ghozy, Sherief , Bayraktar, Esref Alperen , Zarrintan, Armin , Ueki, Yasuhito , Caroff, Jildaz , Kallmes, David F. , Kadirvel, Ramanathan , Zarrintan, Armin , Caroff, Jildaz , Spelle, Laurent , Kadirvel, Ram , Ghozy, Sherief , Cortese, Jonathan , Bayraktar, Esref Alperen , Mihalea, Cristian , Spelle, Laurent

Journal of NeuroInterventional Surgery | August 8, 2024 | Volume: 17 | Issue: 10 | Pages: 1083-1088

10.1136/jnis-2024-022155 Get It

Background Sealing of the aneurysm neck with a Woven EndoBridge (WEB) device is recommended for disrupting the blood flow inside the aneurysm. This study investigates the relationship between WEB neck apposition and aneurysm occlusion rates. Methods Aneurysms treated with a WEB from March 2017 to May 2022 at a single center were included. WEB neck apposition (poor/good) and WEB protrusion (yes/no) were evaluated on post-detachment high resolution cone beam CT images. Angiographic occlusion was assessed with the Bicêtre Occlusion Scale score (BOSS). Univariate and multivariable analysis tested the association between neck apposition and occlusion rates. Results The study included 159 aneurysms in 141 patients (mean age 55.8±11.2 years; 64.2% women). Good neck apposition and protrusion were noted in 123 (77.4%) and 30 (18.9%) cases, respectively. Inter-rater agreements were good for neck apposition (κ=0.75) and protrusion (κ=0.78). Complete and adequate occlusion was achieved in 104 (65%) and 130 (82%) cases, respectively (median follow-up 18 months). Good neck apposition was a strong independent predictor for both adequate (adjusted OR (aOR)=5.9, 95% CI 2.4 to 14.9; P<0.001) and complete occlusion (aOR=7.1, 95% CI 3.0 to 18.1; P<0.001). Protrusion was more frequent in the adequate occlusion group versus the aneurysm recurrence group without reaching statistical significance (P=0.06), but was associated with more thromboembolic complications (9/30 (30%) vs 12/129 (9%); P<0.01). WEB shape modification was significantly greater in poor apposition cases (P=0.03). Conclusions Achieving good neck apposition of the WEB strongly predicts aneurysm occlusion during follow-up. WEB protrusion should be minimized due to the increase in thromboembolic risk with limited impact on aneurysm occlusion.
Creating elastase aneurysms in rabbits: a video primer
Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Bilgin, Cem , Ding, Yong-Hong, Ueki, Yasuhito , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong

Journal of NeuroInterventional Surgery | June 11, 2024 | Volume: 17 | Issue: 10 | Pages: 1133-1133

10.1136/jnis-2024-021912 Get It

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field. Video 1 Surgical procedure of creating elastase-induced aneurysms in rabbits.