Trzasko, Joshua D.

https://orcid.org/0000-0001-8180-5449

Mayo Clinic

Mayo Clinic

Citations 59

The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Gray, Erin M. , Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Foo, Thomas K F

Magnetic Resonance in Medicine | June 23, 2017 | Volume: 79 | Issue: 3 | Pages: 1354-1364

10.1002/mrm.26789 Get It

PurposeTo investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first‐order spatial dependence on fast/turbo spin‐echo acquisitions, and to demonstrate the effectiveness of their real‐time compensation.MethodsAfter briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first‐order CFs on these systems are investigated using extended‐phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real‐time compensations using frequency tracking and gradient pre‐emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan‐based correction to compensate for eddy currents is also investigated.ResultsIt is demonstrated that, unlike the second‐order CFs on conventional gradients, the additional zeroth/first‐order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin‐echo acquisitions within a typical brain‐scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real‐time compensation successfully eliminates the artifacts.ConclusionsWe demonstrate that the zeroth/first‐order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real‐time compensation. Magn Reson Med 79:1354–1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
Weavers, Paul T., Tao, Shengzhen , Trzasko, Joshua D. , Frigo, Louis M., Shu, Yunhong , Frick, Matthew A., Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas K F

Magnetic Resonance in Medicine | June 22, 2017 | Volume: 79 | Issue: 3 | Pages: 1538-1544

10.1002/mrm.26790 Get It

PurposeImaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0) and linear (first‐order) spatial dependence.MethodsThis work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging.ResultsA global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images.ConclusionA user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
Arani, Arvin , Min, Hoon‐Ki , Fattahi, Nikoo , Wetjen, Nicholas M. , Trzasko, Joshua D. , Jack, Clifford R. , Lee, Kendall H. , Min, Hoon-Ki Paul , Manduca, Armando , Ehman, Richard L. , Huston, John , Jack, Clifford R , Arani, Arvin

Magnetic Resonance in Medicine | May 10, 2017 | Volume: 79 | Issue: 2 | Pages: 1043-1051

10.1002/mrm.26738 Get It

PurposeThe homeostasis of intracranial pressure (ICP) is of paramount importance for maintaining normal brain function. A noninvasive technique capable of making direct measurements of ICP currently does not exist. MR elastography (MRE) is capable of noninvasively measuring brain tissue stiffness in vivo, and may act as a surrogate to measure ICP. The objective of this study was to investigate the impact of changing ICP on brain stiffness using MRE in a swine model.MethodsBaseline MRE measurements were obtained, and then catheters were surgically placed into the left and right lateral ventricles of three animals. ICP was systematically increased over the range of 0 to 55 millimeters mercury (mmHg), and stiffness measurements were made using brain MRE at vibration frequencies of 60 hertz (Hz), 90 Hz, 120 Hz, and 150 Hz.ResultsA significant linear correlation between stiffness and ICP in the cross‐subject comparison was observed for all tested vibrational frequencies (P ≤ 0.01). The 120 Hz (0.030 ± 0.004 kilopascal (kPa)/mmHg, P < 0.0001) and 150 Hz (0.031 ± 0.008 kPa/mmHg, P = 0.01) vibrational frequencies had nearly identical slopes, which were approximately two‐ to three‐fold higher than the 90 Hz (0.017 ± 0.002 kPa/mmHg, P < 0.0001) and 60 Hz (0.009 ± 0.002 kPa/mmHg, P = 0.001) slopes, respectively.ConclusionIn this study, MRE demonstrated the potential for noninvasive measurement of changes in ICP. Magn Reson Med 79:1043–1051, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Regional assessment of in vivo myocardial stiffness using 3D magnetic resonance elastography in a porcine model of myocardial infarction
Arunachalam, Shivaram P. , Arani, Arvin , Baffour, Francis , Rysavý, J, Rossman, Phillip J. , Glaser, Kevin J. , Lake, David S. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Rysavy, Joseph A, Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Magnetic Resonance in Medicine | April 6, 2017 | Volume: 79 | Issue: 1 | Pages: 361-369

10.1002/mrm.26695 Get It

Purpose The stiffness of a myocardial infarct affects the left ventricular pump function and remodeling. Magnetic resonance elastography (MRE) is a noninvasive imaging technique for measuring soft‐tissue stiffness in vivo. The purpose of this study was to investigate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE in a porcine model of myocardial infarction, and compare the results with ex vivo uniaxial tensile testing. Methods Myocardial infarct was induced in a porcine model by embolizing the left circumflex artery. Fourteen days postinfarction, MRE imaging was performed in diastole using an echocardiogram‐gated spin‐echo echo‐planar‐imaging sequence with 140‐Hz vibrations and 3D MRE processing. The MRE stiffness and tensile modulus from uniaxial testing were compared between the remote and infarcted myocardium. Results Myocardial infarcts showed increased in vivo MRE stiffness compared with remote myocardium (4.6 ± 0.7 kPa versus 3.0 ± 0.6 kPa, P = 0.02) within the same pig. Ex vivo uniaxial mechanical testing confirmed the in vivo MRE results, showing that myocardial infarcts were stiffer than remote myocardium (650 ± 80 kPa versus 110 ± 20 kPa, P = 0.01). Conclusions These results demonstrate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE. Magn Reson Med 79:361–369, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Cardiac MR elastography for quantitative assessment of elevated myocardial stiffness in cardiac amyloidosis
Arani, Arvin , Arunachalam, Shivaram P. , Chang, Ian C , Baffour, Francis , Rossman, Phillip J. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Grogan, Martha , Dispenzieri, Angela , Araoz, Philip A. , Chang, Ian C Y, Manduca, Armando , Ehman, Richard L. , Dispenzieri, Angela , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Journal of Magnetic Resonance Imaging | February 25, 2017 | Volume: 46 | Issue: 5 | Pages: 1361-1367

10.1002/jmri.25678 Get It

PurposeTo evaluate if cardiac magnetic resonance elastography (MRE) can measure increased stiffness in patients with cardiac amyloidosis. Myocardial tissue stiffness plays an important role in cardiac function. A noninvasive quantitative imaging technique capable of measuring myocardial stiffness could aid in disease diagnosis, therapy monitoring, and disease prognostic strategies. We recently developed a high‐frequency cardiac MRE technique capable of making noninvasive stiffness measurements.Materials and MethodsIn all, 16 volunteers and 22 patients with cardiac amyloidosis were enrolled in this study after Institutional Review Board approval and obtaining formal written consent. All subjects were imaged head‐first in the supine position in a 1.5T closed‐bore MR imager. 3D MRE was performed using 5 mm isotropic resolution oblique short‐axis slices and a vibration frequency of 140 Hz to obtain global quantitativein vivoleft ventricular stiffness measurements. The median stiffness was compared between the two cohorts. An octahedral shear strain signal‐to‐noise ratio (OSS‐SNR) threshold of 1.17 was used to exclude exams with insufficient motion amplitude.ResultsFive volunteers and six patients had to be excluded from the study because they fell below the 1.17 OSS‐SNR threshold. The myocardial stiffness of cardiac amyloid patients (median: 11.4 kPa, min: 9.2, max: 15.7) was significantly higher (P = 0.0008) than normal controls (median: 8.2 kPa, min: 7.2, max: 11.8).ConclusionThis study demonstrates the feasibility of 3D high‐frequency cardiac MRE as a contrast‐agent‐free diagnostic imaging technique for cardiac amyloidosis.Level of Evidence:2Technical Efficacy:Stage 2J. Magn. Reson. Imaging 2017;46:1361–1367.
Slip interface imaging based on MR‐elastography preoperatively predicts meningioma–brain adhesion
Yin, Ziying , Hughes, Joshua , Glaser, Kevin J. , Link, Michael J. , Romano, Anthony J., Hughes, Joshua D, Trzasko, Joshua D. , Van Gompel, Jamie, Manduca, Armando , Gompel, Jamie J. Van , Ehman, Richard L. , Huston, John , Yin, Ziying

Journal of Magnetic Resonance Imaging | February 14, 2017 | Volume: 46 | Issue: 4 | Pages: 1007-1016

10.1002/jmri.25623 Get It

PurposeTo investigate the ability of slip interface imaging (SII), a recently developed magnetic resonance elastography (MRE)‐based technique, to predict the degree of meningioma–brain adhesion, using findings at surgery as the reference standard.Materials and MethodsWith Institutional Review Board approval and written informed consent, 25 patients with meningiomas >2.5 cm in maximal diameter underwent preoperative SII assessment. Intracranial shear motions were introduced using a soft, pillow‐like head driver and the resulting displacement field was acquired with an MRE pulse sequence on 3T MR scanners. The displacement data were analyzed to determine tumor–brain adhesion by assessing intensities on shear line images and raw as well as normalized octahedral shear strain (OSS) values along the interface. The SII findings of shear line images, OSS, and normalized OSS were independently and blindly correlated with surgical findings of tumor adhesion by using the Cohen's κ coefficient and chi‐squared test.ResultsNeurosurgeons categorized the surgical plane as extrapial (no adhesion) in 15 patients, mixed in four, and subpial (adhesion) in six. Both shear line images and OSS agreed with the surgical findings in 18 (72%) cases (fair agreement, κ = 0.37, 95% confidence interval [CI]: 0.05–0.69), while normalized OSS was concordant with the surgical findings in 23 (92%) cases (good agreement, κ = 0.86, 95% CI: 0.67–1). The correlation between SII predictions (shear line images, OSS, and normalized OSS) and the surgical findings were statistically significant (chi‐squared test, P = 0.02, P = 0.02, and P < 0.0001, respectively).ConclusionSII preoperatively evaluates the degree of meningioma–brain adhesion noninvasively, allowing for improved prediction of surgical risk and tumor resectability.Level of Evidence: 1Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2017;46:1007–1016.
Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction
Stinson, Eric G. , Trzasko, Joshua D. , Riederer, Stephen J. , Fletcher, Joel G.

Magnetic Resonance in Medicine | February 2, 2017 | Volume: 78 | Issue: 6 | Pages: 2203-2215

10.1002/mrm.26620 Get It

PurposeThe purpose of this work is to derive and demonstrate constrained‐phase dual‐echo Dixon imaging within a maximum likelihood framework solved with a regularized graph‐cuts‐guided optimization.Theory and MethodsDual‐echo Dixon reconstruction is fundamentally underdetermined; however, adopting a constrained‐phase signal model reduces the number of unknowns and the nonlinear problem can be solved under a maximum likelihood framework. Period shifts in the field map (manifesting as fat/water signal swaps) must also be corrected. Here, a regularized cost function promotes a smooth field map and is solved with a graph‐cuts‐guided greedy binary optimization. The reconstruction shown here is compared to two other prevalent Dixon reconstructions in experimental phantom and human studies.ResultsReconstructed images of the water and fat signal are shown for a phantom study, and in vivo studies of foot/ankle, pelvis, and CE‐MRA of the thighs. The method shown here compared favorably with the other two methods. Large field inhomogeneities on the order of 20 ppm were resolved, thereby avoiding the fat and water signal swaps present in images reconstructed with the other methods.ConclusionConstrained‐phase dual‐echo Dixon imaging solved with a regularized graph‐cuts‐guided optimization has been derived and demonstrated to successfully separate water and fat images in the presence of large magnetic field inhomogeneities. Magn Reson Med 78:2203–2215, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system
Tao, Shengzhen , Trzasko, Joshua D. , Gunter, Jeffrey L. , Weavers, Paul T., Shu, Yunhong , Lee, Seung‐Kyun , Tan, Ek T. , Huston, John , Bernstein, Matt A. , Tan, Ek T

Physics in Medicine & Biology | December 29, 2016 | Volume: 62 | Issue: 2 | Pages: N18-N31

10.1088/1361-6560/aa524f Get It

Abstract Due to engineering limitations, the spatial encoding gradient fields in conventional magnetic resonance imaging cannot be perfectly linear and always contain higher-order, nonlinear components. If ignored during image reconstruction, gradient nonlinearity (GNL) manifests as image geometric distortion. Given an estimate of the GNL field, this distortion can be corrected to a degree proportional to the accuracy of the field estimate. The GNL of a gradient system is typically characterized using a spherical harmonic polynomial model with model coefficients obtained from electromagnetic simulation. Conventional whole-body gradient systems are symmetric in design; typically, only odd-order terms up to the 5th-order are required for GNL modeling. Recently, a high-performance, asymmetric gradient system was developed, which exhibits more complex GNL that requires higher-order terms including both odd- and even-orders for accurate modeling. This work characterizes the GNL of this system using an iterative calibration method and a fiducial phantom used in ADNI (Alzheimer’s Disease Neuroimaging Initiative). The phantom was scanned at different locations inside the 26 cm diameter-spherical-volume of this gradient, and the positions of fiducials in the phantom were estimated. An iterative calibration procedure was utilized to identify the model coefficients that minimize the mean-squared-error between the true fiducial positions and the positions estimated from images corrected using these coefficients. To examine the effect of higher-order and even-order terms, this calibration was performed using spherical harmonic polynomial of different orders up to the 10th-order including even- and odd-order terms, or odd-order only. The results showed that the model coefficients of this gradient can be successfully estimated. The residual root-mean-squared-error after correction using up to the 10th-order coefficients was reduced to 0.36 mm, yielding spatial accuracy comparable to conventional whole-body gradients. The even-order terms were necessary for accurate GNL modeling. In addition, the calibrated coefficients improved image geometric accuracy compared with the simulation-based coefficients.
Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Frigo, Louis M., Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Lee, Seung‐Kyun

Magnetic Resonance in Medicine | July 4, 2016 | Volume: 77 | Issue: 6 | Pages: 2250-2262

10.1002/mrm.26315 Get It

Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis
Arunachalam, Shivaram P. , Rossman, Phillip J. , Arani, Arvin , Lake, David S. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin

Magnetic Resonance in Medicine | March 26, 2016 | Volume: 77 | Issue: 3 | Pages: 1184-1192

10.1002/mrm.26207 Get It

Purpose Magnetic resonance elastography (MRE) is a rapidly growing noninvasive imaging technique for measuring tissue mechanical properties in vivo. Previous studies have compared two‐dimensional MRE measurements with material properties from dynamic mechanical analysis (DMA) devices that were limited in frequency range. Advanced DMA technology now allows broad frequency range testing, and three‐dimensional (3D) MRE is increasingly common. The purpose of this study was to compare 3D MRE stiffness measurements with those of DMA over a wide range of frequencies and shear stiffnesses. Methods 3D MRE and DMA were performed on eight different polyvinyl chloride samples over 20–205 Hz with stiffness between 3 and 23 kPa. Driving frequencies were chosen to create 1.1, 2.2, 3.3, 4.4, 5.5, and 6.6 effective wavelengths across the diameter of the cylindrical phantoms. Wave images were analyzed using direct inversion and local frequency estimation algorithm with the curl operator and compared with DMA measurements at each corresponding frequency. Samples with sufficient spatial resolution and with an octahedral shear strain signal‐to‐noise ratio > 3 were compared. Results Consistency between the two techniques was measured with the intraclass correlation coefficient (ICC) and was excellent with an overall ICC of 0.99. Conclusions 3D MRE and DMA showed excellent consistency over a wide range of frequencies and stiffnesses. Magn Reson Med 77:1184–1192, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.