Back to Authors

Nguyen, Michelle

https://orcid.org/0000-0003-4827-6367

Mayo Clinic

Mayo Clinic

Citations 13

Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters
Su, Leon , Secor, Daniel T. , McGary, Alyssa , Nguyen, Michelle , Kinard, Theresa N. , Adamski, Jill , Stoker, Alex D., Frasco, Peter E. , Su, Leon L , McGary, Alyssa K, Nguyen, Michelle C , Jadlowiec, Caroline , Adamksi, Jill , Stoker, Alex D , Jadlowiec, Caroline C. , Williams, Lance A

Liver Transplantation | October 11, 2024 | Volume: 31 | Issue: 4 | Pages: 464-475

10.1097/lvt.0000000000000507 Get It

The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.
Ex-situ machine perfusion in clinical liver transplantation: Current practices and future directions
Nguyen, Michelle , Li, Xingjie , Linares, Natalia M., Moss, Adyr A. , Reddy, Kunam S. , Mathur, Amit K. , Nguyen, Michelle C , Linares, Natalia, Jadlowiec, Caroline , Mathur, Amit , Jadlowiec, Caroline C.

Liver Transplantation | July 5, 2024 | Volume: 31 | Issue: 4 | Pages: 531-544

10.1097/lvt.0000000000000428 Get It

Ex-situ machine perfusion of the liver has surmounted traditional limitations associated with static cold storage in the context of organ preservation. This innovative technology has changed the landscape of liver transplantation by mitigating ischemia perfusion injury, offering a platform for continuous assessment of organ quality, and providing an avenue for optimizing the use of traditionally marginal allografts. This review summarizes the contemporary clinical applications of machine perfusion devices and discusses potential future strategies for real-time viability assessment, therapeutic interventions, and modulation of organ function after recovery.
Outcomes of dual kidney transplants from high KDPI kidneys are superior compared to single kidney high KDPI transplants at 1 year
Das, Devika , Wagler, Josiah , Ohara, Stephanie , Nguyen, Michelle , Frasco, Peter E. , Smith, Maxwell L. , Khamash, Hasan , Mathur, Amit K. , Budhiraja, Pooja , Reddy, Kunam S. , Heilman, Raymond L. , Smith, Maxwell , Reddy, Kunam S , Heilman, Raymond , Jadlowiec, Caroline , Das, Devika , Ohara, Stephanie Y , Budhiraja, Pooja , Nguyen, Michelle C , Jadlowiec, Caroline C.

Clinical Transplantation | May 28, 2022 | Volume: 36 | Issue: 8 | Pages: No page available

10.1111/ctr.14737 Get It

AbstractDual kidney transplantation (DKT), utilizing two adult kidneys from the same donor for one recipient, has been used as a way to expand the available donor pool. These kidneys often come from high Kidney Donor Profile Index donors (KDPI > 85%). Data comparing outcomes between high KDPI DKT and single kidney transplants (SKT) remain limited. We assessed outcomes of 336 high KDPI kidney transplants performed at our center; 11.0% (n = 37) were DKT. Recipients of DKT were older (P = .02) and donors had a higher KDPI score (median 96% vs. 91%, P < .0001). DKT operative time was higher compared to SKT (+1.4 hours, P < .0001). There were no differences in delayed graft function (54.1% vs. 51.5%, P = .77) and hospital length of stay (median 4.0 vs. 3.0 days, P = .21) between DKT and SKT. Grade I Clavien‐Dindo complications occurred in 8.1% of DKT and 13.7% of SKT (P = .008). There were no grade IVa, IVb, or V complications in either group. DKT had more glomerulosclerosis (P = .04), interstitial fibrosis (P = .02), tubular atrophy (P = .01), and arterial thickening (P = .03) on 1‐year protocol biopsies. Estimated glomerular filtration was higher for DKT at 1‐ (P = .004) and 2‐years post‐transplant (P = .01). There were no differences in patient (HR 1.3, 95% CI .5‐3.3, P = .58) or graft (HR 1.1, 95% CI .5‐2.3, P = .83) survival. Good outcomes can be achieved with DKT using high KDPI kidneys with moderate chronic changes. DKT is a good option to help further utilize high KDPI kidneys and minimize discard.