Background: Conventional transthoracic echocardiography (TTE) is currently not recommended as an initial test to diagnose coronary artery disease (CAD) due to its insensitivity. Left ventricular (LV) strain was reported to be more sensitive than regional wall motion abnormality (RWMA). The aim of this study was to evaluate the usefulness of TTE including LV strain analysis in initial assessment of acute chest pain in emergency department (ED). Methods: Patients visiting ED with acute chest pain were included. Patients with ST elevation myocardial infarct (MI), hemodynamic instability, known CAD or cardiomyopathy, high probability of non-cardiac chest pain, and poor echocardiographic window were excluded. All the patients were initially assessed by an ED physician for pretest probability of CAD. TTE was performed including LV strain image and global and regional LV longitudinal stain (S GL and S RL ) was analyzed online. S RL abnormality was defined as decreased S RL in at least 2 adjacent segments. Diagnosis of CAD (based on coronary angiography or CT angiography) and cardiac events (cardiac death, revascularization, MI, or recurrent ED visit due to chest pain) were reviewed at 1 month after ED visit. Results: Overall 104 patients were analyzed. CAD was diagnosed in 24% (n=25) and cardiac event was detected in 25% (n=26) of patients.Diagnostic accuracy for CAD was higher when using S RL with cut-off value of -13% (sensitivity of 89%, specificity of 77%, NPV = 92%, PPV = 70%) than when using RWMA (sensitivity of 62%, specificity of 88%, NPV = 80%, PPV = 76%). S RL showed better diagnostic performance for CAD than S GL , and pretest probability (Figure). Predictive value of S RL for cardiac events was also highest in those of S GL , RWMA, and pretest probability (Figure). Conclusion: LV strain echocardiography can diagnose the CAD and predict future events with high accuracy. TTE including strain analysis can be used as an initial diagnostic tool in evaluation of acute chest pain in ED.
Abstract 16885: Progression of Aortic Valve Stenosis in Atrial Fibrillation versus Sinus Rhythm: Implications for Clinical Practice and Severe Aortic Stenosis Diagnosis
Introduction: Rate of aortic stenosis (AS) progression in patients with concurrent atrial fibrillation (AF) has not been previously described. Objectives: To describe changes over time in aortic valve area (AVA) and associated hemodynamics during AS progression in patients in AF versus sinus rhythm (SR). Methods: Patients with AVA ≤ 1 cm 2 and preserved left ventricular ejection fraction ≥50% were identified from the Mayo Clinic Echocardiographic Laboratory Database. Serial echocardiograms prior to the development of AVA ≤ 1 cm 2 (Time 0) were examined. Inverse probability weighting was used for statistical analysis. Results: A total of 166 patients were included (SR=79 and AF=87), mean age 78.1 ± 7.8 years, females 31%. The rates of AVA reduction (-0.14±0.01 vs -0.12±0.01 cm2/year, p=0.31) and increase in trans-aortic peak velocity (+0.23 ± 0.02 vs +0.22 ± 0.02 m/sec, p=0.55) and mean gradient (MG) (3.9 ± 0.3 vs 3.8 ± 0.4 mmHg, p=0.83) did not differ between AF and SR (Figure 1). However, AF was associated with systematically lower forward stroke volume index (SVi), peak velocity and MG for the same AVA compared to SR (p<0.04 for all) throughout AS progression. When AVA reached 1 cm 2 , SVi (38.8±6.6 vs 45.7 ±8.9, p=0.02), peak velocity (3.9 ± 0.6 vs 4.1 ± 0.6 m/sec, p=0.04) and MG (36.6±10.9 vs 41±12.8 mmHg, p=0.03) were lower in AF compared to SR. Conclusions: The rate of AS progression was not different in AF versus SR. However, forward flow was systematically lower in AF resulting in discordant AS during AS progression and when AVA reached 1 cm 2 . Doppler velocity and MG criteria for severe AS appear to be lower in AF versus SR which has implications for timely diagnosis of severe AS and patient management.
Abstract 14666: Prognostic Value of Artificial Intelligence-Enabled ECG for Increased Left Ventricular Filling Pressure
Introduction: Left ventricular diastolic function and filling pressure (FP) can be assessed by echocardiography and cardiac catheterization. Recently, a novel artificial intelligence (AI)-enabled ECG has proven to be effective in identifying increased FP determined by echocardiographic assessment of diastolic function. Aims: We aimed to compare a prognostic value of AI-ECG determination of FP compared to echocardiography and catheterization. Methods: This study included 4,213 patients who had a transthoracic echocardiogram and ECG within 30 days before hemodynamic cardiac catheterization. Increased FP was defined as pulmonary artery wedge pressure >15 mmHg by catheterization and grade 2 or 3 diastolic dysfunction by echocardiography based on diastolic function guidelines. Increased FP by ECG was identified using previously developed AI-ECG. AI-ECG performance was evaluated using the area under the curve (AUC) of the receiver operating curve. We assessed the risk of all-cause mortality using Kaplan-Meier estimate and multivariable Cox proportional-hazards models. Results: AI-ECG had AUCs of 0.8 and 0.7 for predicting increased FP determined by echocardiography and catheterization, respectively. Death was observed in 2,776 (34%) patients over a median follow-up of 7.7 years (IQR 7.1, 8.3). Survival of patients with normal and increased FP by AI-ECG, Echocardiography, and catheterization are shown in Figure 1a. Concordant diagnoses of normal and increased FP by AI-ECG and catheterization or echocardiography had the highest and lowest survival rates, respectively. When FP by AI-ECG was discordant, survival was better predicted by AI-ECG compared to echocardiography and catheterization (Figure 1b). Conclusion: AI-ECG for FP has a potential to discriminate prognosis further compared to FP determined by echocardiography or catheterization.
Noninvasive Hemodynamic Characterization of Shock and Preshock Using Echocardiography in Cardiac Intensive Care Unit Patients
Background Shock and preshock are defined on the basis of the presence of hypotension, hypoperfusion, or both. We sought to determine the hemodynamic underpinnings of shock and preshock noninvasively using transthoracic echocardiography (TTE). Methods and Results We included Mayo Clinic cardiac intensive care unit patients from 2007 to 2015 with TTE within 1 day of admission. Hypotension and hypoperfusion at the time of cardiac intensive care unit admission were used to define 4 groups. TTE findings were evaluated across these groups, and in‐hospital mortality was evaluated according to TTE findings in each group. We included 5375 patients with a median age of 69.2 years (36.8% women). The median left ventricular ejection fraction was 50%. Groups based on hypotension and hypoperfusion were assigned as follows: no hypotension or hypoperfusion, 59.7%; isolated hypotension, 15.3%; isolated hypoperfusion, 16.4%; and both hypotension and hypoperfusion, 8.7%. Most TTE variables of interest varied across these groups, with worse biventricular function, lower forward flow, and higher filling pressures as the degree of hemodynamic compromise increased. In‐hospital mortality occurred in 8.2%, and inpatient deaths had more TTE parameter abnormalities. In‐hospital mortality increased with the degree of hemodynamic compromise, and a marked gradient in in‐hospital mortality was observed when the clinical classification of shock and preshock was combined with TTE findings reflecting worse biventricular function, lower forward flow, or higher filling pressures. Conclusions Substantial differences in cardiac function are observed between cardiac intensive care unit patients with preshock and shock using TTE, and the combination of the clinical and TTE hemodynamic assessment provides robust mortality risk stratification.
Aortic Valve Calcium Score by Computed Tomography as an Adjunct to Echocardiographic Assessment—A Review of Clinical Utility and Applications
Aortic valve stenosis (AS) is increasing in prevalence due to the aging population, and severe AS is associated with significant morbidity and mortality. Echocardiography remains the mainstay for the initial detection and diagnosis of AS, as well as for grading of severity. However, there are important subgroups of patients, for example, patients with low-flow low-gradient or paradoxical low-gradient AS, where quantification of severity of AS is challenging by echocardiography and underestimation of severity may delay appropriate management and impart a worse prognosis. Aortic valve calcium score by computed tomography has emerged as a useful clinical diagnostic test that is complimentary to echocardiography, particularly in cases where there may be conflicting data or clinical uncertainty about the degree of AS. In these situations, aortic valve calcium scoring may help re-stratify grading of severity and, therefore, further direct clinical management. This review presents the evolution of aortic valve calcium score by computed tomography, its diagnostic and prognostic value, as well as its utility in clinical care.
The role of serum lipoprotein(a) levels in bioprosthetic aortic valve degeneration
Abstract Introduction Lipoprotein(a) [Lp(a)] is associated with an increased incidence of aortic stenosis. Bioprosthetic aortic valve degeneration and native aortic stenosis share similar pathological mechanisms. Evidence regarding the role of serum Lp(a) concentrations in bioprosthetic aortic valve degeneration is lacking. Purpose To evaluate the association between serum Lp(a) concentrations and bioprosthetic aortic valve degeneration. Methods In this retrospective multicenter study, consecutive patients who underwent a bioprosthetic aortic valve replacement between Jan-2010 and Dec-2020 and had a preoperatory serum Lp(a) measurement were included. A baseline transthoracic echocardiography (TTE) was performed following the aortic valve replacement and a follow-up TTE was performed at least 24 months after the baseline study to determine the presence of bioprosthetic valve degeneration. Significant degeneration was defined as: (a) an increase >10 mmHg in mean bioprosthetic aortic valve gradient from baseline status + a decrease in effective orifice area + a decrease in Doppler velocity index + exclusion of clinically thrombotic leaflet thickening, OR (b) new moderate or severe prosthetic aortic regurgitation (if the main component was periprosthetic, then it was not considered). Lp(a) concentrations were compared between patients with and without degeneration and regression analysis was conducted to investigate the association between bioprosthetic valve degeneration and Lp(a) levels. Results In total, 211 cases were included (mean age 74.1 ±9.4 years, 72.0% males, 29.9% transcatheter aortic valve replacements) (Figure 1). Median time between baseline and follow-up TTE was 5.0 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.6%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in the patients affected by degeneration versus non-affected cases (50.0 vs 15.7 mg/dl, p=0.003). In the regression analysis, high Lp(a) levels (≥30 mg/dl) were associated with degeneration both in a univariate analysis (OR 4.8, 95%CI 2.2-10.9, p<0.001) and multivariate analysis adjusted by other risk factors for bioprostheses degeneration (age, sex, hypertension, smoking, patient prosthesis mismatch, creatinine levels, and body surface area) (OR 5.2, 95%CI 2.1-12.8, p<0.001). Conclusion Serum Lp(a) concentrations seem to be a risk factor for bioprosthetic aortic valve degeneration (Figure 2). There is an increasing need to accurately predict bioprosthetic aortic valve degeneration and to develop novel methods and treatments to increase their durability. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) could slow bioprostheses degradation.Population characteristicsLp(a) and bioprostheses degeneration
MicroRNA-30d and -483-3p for Bi-Ventricular Remodelling and miR-126-3p for Pulmonary Hypertension in Advanced Heart Failure
Abstract Aims MicroRNAs play a role in pathogenic mechanisms leading to heart failure. We measured a panel of 754 miRNAs in the myocardial tissue and in the serum of patients with heart failure with reduced ejection fraction due to dilatative idiopathic cardiomyopathy (DCM, N = 10) or ischaemic cardiomyopathy (N = 3), referred to left ventricular assist device implant. We aim to identify circulating miRNAs with high tissue co-expression, significantly associated to echocardiographic and haemodynamic measures. Methods and results We have measured a panel of 754 miRNAs in the myocardial tissue [left ventricular (LV) apex] and in the serum obtained at the same time in a well selected study population of end-stage heart failure with reduced ejection fraction due to either DCM or ischaemic cardiomyopathy, referred to continuous flow left ventricular assist device implant. We observed moderate agreement for miR-30d, miR-126-3p, and miR-483-3p. MiR-30d was correlated to LV systolic as well as diastolic volumes (r = 0.78, P = 0.001 and r = 0.80, P = 0.005, respectively), while miR-126-3p was associated to mPAP and PCWP (r = −0.79, P = 0.007 and r = −0.80, P = 0.005, respectively). Finally, serum miR-483-3p had an association with right ventricular end diastolic diameter (r = −0.73, P = 0.02) and central venous pressure (CVP) (r − 0.68 p 0.03). Conclusions In patients with DCM, few miRNAs are co-expressed in serum and tissue: They are related to LV remodelling (miR-30d), post-capillary pulmonary artery pressure (miR-126-3p), and right ventricular remodelling/filling pressures (miR-483-3p). Further studies are needed to confirm their role in diagnosis, prognosis or as therapeutic targets in heart failure with reduced ejection fraction.
Challenges and solutions of echocardiography generalization for deep learning: a study in patients with constrictive pericarditis
Objectives Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. Methods In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. Results In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). Conclusions High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.
Bicuspid aortic valve: long-term morbidity and mortality
Abstract Background and Aims Bicuspid aortic valve (BAV) is the most common congenital heart anomaly. Lifetime morbidity and whether long-term survival varies according to BAV patient-sub-groups are unknown. This study aimed to assess lifetime morbidity and long-term survival in BAV patients in the community. Methods The authors retrospectively identified all Olmsted County (Minnesota) residents with an echocardiographic diagnosis of BAV from 1 January 1980 to 31 December 2009, including patients with typical valvulo-aortopathy (BAV without accelerated valvulo-aortopathy or associated disorders), and those with complex valvulo-aortopathy (BAV with accelerated valvulo-aortopathy or associated disorders). Results 652 consecutive diagnosed BAV patients [median (IQR) age 37 (22–53) years; 525 (81%) adult and 127 (19%) paediatric] were followed for a median (IQR) of 19.1 (12.9–25.8) years. The total cumulative lifetime morbidity burden (from birth to age 90) was 86% (95% CI 82.5–89.7); cumulative lifetime progression to ≥ moderate aortic stenosis or regurgitation, aortic valve surgery, aortic aneurysm ≥45 mm or z-score ≥3, aorta surgery, infective endocarditis and aortic dissection was 80.3%, 68.5%, 75.4%, 27%, 6% and 1.6%, respectively. Survival of patients with typical valvulo-aortopathy [562 (86%), age 40 (28–55) years, 86% adults] was similar to age-sex-matched Minnesota population (P = .12). Conversely, survival of patients with complex valvulo-aortopathy [90 (14%), age 14 (3–26) years, 57% paediatric] was lower than expected, with a relative excess mortality risk of 2.25 (95% CI 1.21–4.19) (P = .01). Conclusion The BAV condition exhibits a high lifetime morbidity burden where valvulo-aortopathy is close to unavoidable by age 90. The lifetime incidence of infective endocarditis is higher than that of aortic dissection. The most common BAV clinical presentation is the typical valvulo-aortopathy with preserved expected long-term survival, while the complex valvulo-aortopathy presentation incurs higher mortality.