Back to Authors

Naqvi, Tasneem Z

0000-0002-3160-9025

Mayo Clinic

Division of Echocardiography, Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, AZ.

Citations 9

LOOPS for thought: identifying gastrointestinal pathology on transthoracic echocardiography
Elsayed, Ahmed Magdy , Arsanjani, R A, Naqvi, Tasneem Z. , Magdy, Ahmed , Naqvi, Tasneem Z , Arsanjani, Reza

European Heart Journal - Case Reports | May 8, 2026 | Volume: 10 | Issue: 5 | Pages: No page available

10.1093/ehjcr/ytag339 Get It

Abstract Background Transthoracic echocardiography (TTE) is the most commonly used modality for the diagnosis and follow-up of cardiac diseases. During routine TTE, surrounding extracardiac structures are often visualized, including the lungs, pleural spaces, oesophagus, diaphragm, and sub-diaphragmatic structures such the liver, stomach, bowel, and abdominal aorta. Pathologic conditions affecting these organs may exert extrinsic compression on the cardiac chambers, leading to diagnostic uncertainty or mimicking cardiac disease by producing symptoms, such as dyspnoea, fatigue, chest pain, or palpitations. Case summary We describe five patients who underwent routine TTE and were incidentally found to have unsuspected gastrointestinal abnormalities. The findings subsequently confirmed by other imaging modalities included hiatal hernia, distended bowel loops, oesophageal carcinoma, and oesophageal varices. Reporting of these findings impacted the diagnosis and management of the cases. Conclusion Awareness of the sonographic appearance of gastrointestinal during TTE is essential, as these findings may represent clinically significant pathology that mimics or contributes to cardiac symptoms. Recognition of such findings may be enhanced by modified echocardiographic views, with confirmatory evaluation using chest radiography, computed tomography, or gastrointestinal endoscopy as appropriate
Chronic Right Ventricular Pacing Post-Transcatheter Aortic Valve Replacement Attenuates the Benefit on Left Ventricular Function
Chao, Chieh‐Ju , Mandale, Deepa, Girardo, Marlene , Agasthi, Pradyumma, Alkhouli, Mohammad, Eleid, Mackram F. , Fortuin, F. David , Sweeney, John P., Pollak, Peter , Sabbagh, Abdallah El , Holmes, David R. , Arsanjani, Reza , Naqvi, Tasneem Z. , Abdou, Merna , Eleid, Mackram, Arsanjani, Reza , Naqvi, Tasneem Z , Chao, Chieh-Ju , Farina, Juan M. , Abdou, Merna , Rattanawong, Pattara

Journal of Clinical Medicine | August 5, 2024 | Volume: 13 | Issue: 15 | Pages: 4553

10.3390/jcm13154553 Get It

Background: Conduction abnormality post-transcatheter aortic valve implantation (TAVI) remains clinically significant and usually requires chronic pacing. The effect of right ventricular (RV) pacing post-TAVI on clinical outcomes warrants further studies. Methods: We identified 147 consecutive patients who required chronic RV pacing after a successful TAVI procedure and propensity-matched these patients according to the Society of Thoracic Surgeons (STS) risk score to a control group of patients that did not require RV pacing post-TAVI. We evaluated routine echocardiographic measurements and performed offline speckle-tracking strain analysis for the purpose of this study on transthoracic echocardiographic (TTE) images performed at 9 to 18 months post-TAVI. Results: The final study population comprised 294 patients (pacing group n = 147 and non-pacing group n = 147), with a mean age of 81 ± 7 years, 59% male; median follow-up was 354 days. There were more baseline conduction abnormalities in the pacing group compared to the non-pacing group (56.5% vs. 41.5%. p = 0.01). Eighty-eight patients (61.6%) in the pacing group required RV pacing due to atrioventricular (AV) conduction block post-TAVI. The mean RV pacing burden was 44% in the pacing group. Left ventricular ejection fraction (LVEF) was similar at follow-up in the pacing vs. non-pacing groups (57 ± 13.0%, 59 ± 11% p = 0.31); however, LV global longitudinal strain (−12.7 ± 3.5% vs. −18.8 ± 2.7%, p < 0.0001), LV apical strain (−12.9 ± 5.5% vs. 23.2 ± 9.2%, p < 0.0001), and mid-LV strain (−12.7 ± 4.6% vs. −18.7 ± 3.4%, p < 0.0001) were significantly worse in the pacing vs. non-pacing groups. Conclusions: Chronic RV pacing after the TAVI procedure is associated with subclinical LV systolic dysfunction within 1.5 years of follow-up.
Hand-Held Echocardiography by Advanced Practice Providers in Patients with Congestive Heart Failure
Tagle-Cornell, Maria Cecilia , Novais, Barbara S., Wen, Songnan , Shipman, Justin , Mandale, Deepa, Flom, Andrew P., Sahnan, Sandeep, Kriz, Lindsey M., Alland, Michelle L., Bird, Christen W., Naqvi, Tasneem Z. , Shipman, Justin N, Mandale, Deepa R, Sahnan, Sandeep K, Naqvi, Tasneem Z

Journal of Clinical Medicine | January 5, 2024 | Volume: 13 | Issue: 2 | Pages: 312

10.3390/jcm13020312 Get It

Objectives: The performed hand-held echocardiography (HHE) was evaluated and interpreted by trained advanced practice providers (APPs) on hospitalized CHF patients for image quality and interpretation by comparing with expert echocardiographer and SE findings. Background: Congestive heart failure (CHF) is associated with increased hospital admissions and mortality. While a standard echocardiogram (SE) is the gold standard for cardiac assessment, it is not readily available. Hospitalized CHF patients require rapid assessment for expedited treatment. Methods: Over 6 months, five trained APPs performed HHE on hospitalized CHF patients and interpreted: (a) left ventricular (LV) size, (b) LV ejection fraction (LVEF), and (c) right atrial pressure (RAP). The study echocardiographer reviewed and blindly interpreted the HHE images and compared them with APPs and SE findings. Kappa statistics determined the degree of agreement between APPs and the study echocardiographer’s interpretation of the HHE images and SE. Results: A total of 80 CHF patients (age 73 ± 14 years, 58% males; LVEF (by SE) 45 ± 19%; 36.3% body mass indexes ≥ 30 kg/m2) were enrolled. HHE interpretation by APPs had a good agreement for LVEF (kappa 0.79) with the study echocardiographer and SE (kappa 0.74) and a good agreement for RAP (kappa 0.67) with the study echocardiographer. The correlation between the absolute LVEF interpretation by the study echocardiographer on HHE and SE was r = 0.88 (p < 0.0001). Conclusions: Trained APPs obtained diagnostic-quality HHE images and interpreted the LV function and RAP in CHF patients in good agreement with the study echocardiographer. LVEF by HHE correlated with LVEF by SE. Our study suggests trained APPs can use HHE to evaluate LVEF and RAP in CHF patients, leading to expedited and optimized treatment.
Aortic Valve Calcium Score by Computed Tomography as an Adjunct to Echocardiographic Assessment—A Review of Clinical Utility and Applications
Scalia, Isabel G. , Farina, Juan M. , Padang, Ratnasari , Jokerst, Clinton, Pereyra, Milagros , Mahmoud, Ahmed , Naqvi, Tasneem Z. , Oh, Jae K. , Arsanjani, Reza , Arsanjani, Reza , Naqvi, Tasneem Z , Farina, Juan M , Pereyra, Milagros , Mahmoud, Ahmed K , Scalia, Isabel G , Chao, Chieh‐Ju

Journal of Imaging | November 16, 2023 | Volume: 9 | Issue: 11 | Pages: 250

10.3390/jimaging9110250 Get It

Aortic valve stenosis (AS) is increasing in prevalence due to the aging population, and severe AS is associated with significant morbidity and mortality. Echocardiography remains the mainstay for the initial detection and diagnosis of AS, as well as for grading of severity. However, there are important subgroups of patients, for example, patients with low-flow low-gradient or paradoxical low-gradient AS, where quantification of severity of AS is challenging by echocardiography and underestimation of severity may delay appropriate management and impart a worse prognosis. Aortic valve calcium score by computed tomography has emerged as a useful clinical diagnostic test that is complimentary to echocardiography, particularly in cases where there may be conflicting data or clinical uncertainty about the degree of AS. In these situations, aortic valve calcium scoring may help re-stratify grading of severity and, therefore, further direct clinical management. This review presents the evolution of aortic valve calcium score by computed tomography, its diagnostic and prognostic value, as well as its utility in clinical care.
Point-of-Care Ultrasound in Detection, Severity and Mechanism of Significant Valvular Heart Disease and Clinical Management
Wen, Songnan , Naqvi, Tasneem Z. , Naqvi, Tasneem Z

Journal of Clinical Medicine | October 12, 2023 | Volume: 12 | Issue: 20 | Pages: 6474

10.3390/jcm12206474 Get It

Background: Early diagnosis of significant valvular heart disease (VHD) enables appropriate implementation of the best therapeutic strategy and follow-up. Cardiac auscultation remains suboptimal in early detection of VHD. The aim of this study was to evaluate the utility of point-of-care ultrasound (POCUS) for early detection of VHD and its severity. Methods: All consecutive patients with VHD who did not have a standard echocardiogram prior to first outpatient cardiology consultation underwent history and physical examination followed by POCUS study by an experienced physician in a general cardiology clinic from June 2017 to August 2022 at our institution. Subsequent standard transthoracic echocardiography (sTTE) was performed as the gold standard. Comparison was performed between POCUS and sTTE for the presence and severity of VHD. sTTE was performed by registered cardiac sonographers and interpreted by another cardiologist blinded to the POCUS results. Results: A total of 77 patients were studied (ge 72 ± 11 years, 58.4% males). A total of 89 significant valvular abnormalities were diagnosed. There were 39 (43.8%) cases of regurgitant VHD, 16 (18.0%) of stenotic VHD and 34 (38.2%) had evaluation for prosthetic valve function. The sensitivity (90.9%; 82.4%; 83.3%; 100%) and specificity (100%; 96.7%; 100%; 100%) were high for detecting ≥ moderate aortic regurgitation (AR), mitral regurgitation (MR), aortic stenosis (AS) and prosthetic valvular abnormality, respectively. The weighted κ coefficient between POCUS and sTTE for the assessment of ≥ moderate MR, AR and AS was 0.81 (95% CI, 0.65–0.97), 0.94 (95% CI, 0.84–1.00) and 0.88 (95% CI, 0.76–1.0), respectively, indicating excellent agreement. Conclusions: POCUS can identify patients with significant VHD and may serve as a powerful screening tool for early detection of significant VHD in the outpatient clinical practice with downstream impact on clinical management of significant VHD.
Three-Dimensional Transesophageal Echocardiography in Percutaneous Catheter-Based Cardiac Interventions
Farina, Juan M. , Barry, Timothy , Arsanjani, Reza , Naqvi, Tasneem Z. , Naqvi, Tasneem Z , Arsanjani, Reza , Farina, Juan M

Journal of Clinical Medicine | August 31, 2023 | Volume: 12 | Issue: 17 | Pages: 5664

10.3390/jcm12175664 Get It

Cardiac structural and valve interventions have remained surgical procedures for several decades. The ability to directly visualize the region of interest during surgery made imaging of these structures pre- and postsurgery a secondary tool to compliment surgical visualization. The last two decades, however, have seen rapid advances in catheter-based percutaneous structural heart interventions (SHIs). Due to the “blind” nature of these interventions, imaging plays a crucial role in the success of these procedures. Fluoroscopy is used universally in all percutaneous cardiac SHIs and helps primarily in the visualization of catheters and devices. However, success of these procedures requires visualization of intracardiac soft tissue structures. Due to its portable nature and rapid ability to show cardiac structures online, transesophageal echocardiography (TEE) has become an integral tool for guidance for all percutaneous SHI. Transcatheter aortic valve replacement—one of the earliest catheter-based procedures—while initially dependent on TEE, has largely been replaced by preprocedural cardiac CT for accurate assessment of valve sizing. Developments in echocardiography now allow live three-dimensional (3D) visualization of cardiac structures mimicking surgical anatomy during TEE. Besides showing actual 3D intracardiac structures, 3D-TEE allows visualization of the interaction of intracardiac catheters and devices with soft tissue cardiac structures, thereby becoming a “second pair of eyes” for the operator. Real-time 3D-TEE now plays an important role complementing multiplane two dimensional and biplane TEE during such interventions. In this review, we discuss the incremental role of 3D-TEE during various SHIs performed today.
Post‐cardioversion atrial stunning – Not to be forgotten
Naqvi, Tasneem Z. , Kurt, Merve, Naqvi, Tasneem Z , Kurt, Merve

Echocardiography | January 4, 2023 | Volume: 40 | Issue: 3 | Pages: 266-270

10.1111/echo.15517 Get It

AbstractWe present a case of a 60‐year‐old male who was found to be in atrial fibrillation during routine evaluation. Anticoagulation was initiated for 36 h and he was referred for TEE‐guided electrical cardioversion. There was no thrombus identified in the left atrial appendage, however, the appendage was large and had a tongue‐like accessory lobe along with spontaneous contrast in the left atrium and its appendage. TEE probe was not withdrawn, patient underwent successful cardioversion with 200 joules and developed a marked increase in left atrial and left atrial appendage spontaneous contrast along with the development of tear drop shaped thrombus in the left atrial appendage immediately after cardioversion, which rapidly became more dense. There was an associated marked decrease in appendage velocities. Patient was hospitalized to initiate low molecular weight heparin. This case highlights the need for vigilance in patients with an unknown duration of atrial fibrillation, who have received a short duration of anticoagulant therapy and who have adverse appendage anatomy as thrombus may develop immediately after cardioversion despite anticoagulation.
Quantitation of valve regurgitation severity by three‐dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography
Abudiab, Muaz M. , Naqvi, Tasneem Z. , Liu, Shuang , Naqvi, Tasneem Z , Chao, Chieh‐Ju , Liu, Shuang

Echocardiography | May 8, 2017 | Volume: 34 | Issue: 7 | Pages: 992-1001

10.1111/echo.13549 Get It

BackgroundQuantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three‐dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE).MethodsWe evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE‐recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade.ResultsMean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively.ConclusionMeasurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves.