Objectives: The performed hand-held echocardiography (HHE) was evaluated and interpreted by trained advanced practice providers (APPs) on hospitalized CHF patients for image quality and interpretation by comparing with expert echocardiographer and SE findings. Background: Congestive heart failure (CHF) is associated with increased hospital admissions and mortality. While a standard echocardiogram (SE) is the gold standard for cardiac assessment, it is not readily available. Hospitalized CHF patients require rapid assessment for expedited treatment. Methods: Over 6 months, five trained APPs performed HHE on hospitalized CHF patients and interpreted: (a) left ventricular (LV) size, (b) LV ejection fraction (LVEF), and (c) right atrial pressure (RAP). The study echocardiographer reviewed and blindly interpreted the HHE images and compared them with APPs and SE findings. Kappa statistics determined the degree of agreement between APPs and the study echocardiographer’s interpretation of the HHE images and SE. Results: A total of 80 CHF patients (age 73 ± 14 years, 58% males; LVEF (by SE) 45 ± 19%; 36.3% body mass indexes ≥ 30 kg/m2) were enrolled. HHE interpretation by APPs had a good agreement for LVEF (kappa 0.79) with the study echocardiographer and SE (kappa 0.74) and a good agreement for RAP (kappa 0.67) with the study echocardiographer. The correlation between the absolute LVEF interpretation by the study echocardiographer on HHE and SE was r = 0.88 (p < 0.0001). Conclusions: Trained APPs obtained diagnostic-quality HHE images and interpreted the LV function and RAP in CHF patients in good agreement with the study echocardiographer. LVEF by HHE correlated with LVEF by SE. Our study suggests trained APPs can use HHE to evaluate LVEF and RAP in CHF patients, leading to expedited and optimized treatment.
New pathological illuminations on 3D transillumination transesophageal echocardiography imaging
AbstractThe use of 3D technology has significantly improved the diagnostic accuracy of echocardiography by overcoming the limitation of 2D echocardiography. Transillumination 3D image post processing technique enhances shadows and contrast of cardiac structures with a movable virtual light source improving further the clarity and detail provided by conventional 3D imaging. In this report, we present 3 cases, one of mobile atherosclerotic aortic root plaque, another of small thrombi on ICD lead, and a third case of bicuspid aortic valve perforation due to infective endocarditis in whom TEE 3D transillumination further improved the diagnostic quality of conventional 3D imaging and lead to accurate clinical diagnosis.