Background: Left atrial (LA) strain is a marker of atrial myopathy and remodeling. While echocardiographic LA strain is increasingly used to assess atrial function, the prognostic value of change in LA strain before and after catheter ablation (CA) for atrial fibrillation (AF) remains underexplored. Objective: To evaluate the association between quartiles of LA strain parameters—including pre-ablation strain, post-ablation strain, and change in strain—with atrial fibrillation recurrence, stratified by ejection fraction (EF). Methods: This retrospective study encompassed AF patients who underwent their first CA at Mayo Clinic Arizona from Oct 2018 to Feb 2022. Transthoracic echocardiography parameters, including the three LA strain (LAS) phases—contraction, conduit, and reservoir—were collected using TOMTEC software on the closest date before the CA procedure. Logistic regression analysis was used to evaluate the association between LAS parameters and AF recurrence post-CA, adjusted for clinical covariates including age, gender, hypertension, diabetes, coronary artery disease, dyslipidemia, obstructive sleep apnea, thromboembolism, TIA/stroke, chronic kidney disease, and AF type. Results: Out of 335 patients who underwent CA, 222 had both pre- and post-ablation LA strain data. Among these, 71 of 222 patients (31.98%) experienced AF recurrence after CA. The mean age at time of procedure was 66.9 ± 10.3 years; 150 (67.57%) were male, and 83 (37.39%) had persistent AF. Significant associations were observed between specific quartiles of LA strain and AF recurrence. In patients with EF >50%, Q4 of contraction strain change (pre- vs. post-ablation) was strongly associated with increased recurrence risk (OR 8.80; 95% CI 1.80–42.98). Similarly, post-ablation contraction strain Q4 was associated with higher recurrence in both the overall group (OR 6.36; 95% CI 1.47–27.53) and the EF>50% subgroup (OR 8.80; 95% CI 1.80–42.98). In contrast, reservoir strain change Q2 (OR 0.10; 95% CI 0.01–0.86), and post-ablation reservoir strain Q3 (OR 0.09; 95% CI 0.01–0.69) and Q4 (OR 0.10; 95% CI 0.02–0.70) were protective. Conclusions: Greater increases in contraction strain post-ablation and higher post-ablation contraction strain were strongly associated with AF recurrence, particularly in those with preserved EF. Conversely, favorable reservoir strain post-ablation was protective. LA strain may offer key prognostic value in risk-stratifying AF patients undergoing ablation.
Abstract 4141988: The Power Duo: Combining LA Volume Index and Strain to predict AF Recurrence after ablation
Background: Catheter ablation (CA) is an effective treatment for atrial fibrillation (AF), but many patients experience recurrence post-intervention. Evaluating left atrial strain (LAS) to measure LA reservoir strain (LASr), conduit strain (LAScd), and contractile strain (LASct) could help predict AF recurrence, especially in patients with no evident signs of severe LA myopathy. Goal: This study aims to assess the prognostic value of pre-ablation LAS in both paroxysmal AF (paAF) and persistent AF(peAF) in patients with no evident signs of severe LA myopathy. Methods: This retrospective study encompassed AF patients who underwent their first CA procedure at Mayo Clinic Arizona from October 2018 to February 2022 and had a LAVI <40 ml/m2 and LVEF >55%. Transthoracic echocardiography parameters, including the three LAS phases, were collected using TOMTEC software on the closest date before the CA procedure. Receiver operating characteristic (ROC) curve analysis was used to evaluate the capability of LAS to detect patients with AF recurrence after CA from those without recurrence. Results: Out of 335 AF patients who underwent CA during the study period, 40 cases had LAVI <40 ml/m2 and LVEF >55% (72.5% male; mean age 69.2 ± 8 years). Of these, 15% (6/40) experienced recurrence, while 85% (34/40) maintained sinus rhythm. The mean values of LASr, LAScd, and LASct for all patients were 16.82, 11.23, and 6.87, respectively. ROC analysis indicated that the area under the curve (AUC) for LASr, LAScd, and LASct was 0.582, 0.502, and 0.710, respectively. (Graph 1A, Table 1A) LASct was the only parameter associated with AF recurrence (AUC: 0.71). Additionally, we developed a novel marker termed LAVI-LASct by combining LAVI and LASct values, which demonstrated improved discrimination with an ROC value of 0.74 (Graph 1B). Conclusions: LASct demonstrated predictive capability for AF recurrence in patients with no severe LA dilation and preserved LVEF, potentially due to its ability to detect early atrial dysfunction preceding visible structural changes or myocardial pathology. The addition of LAVI values provided better discrimination for the ROC model. Further research is needed to confirm the clinical relevance of LAS in AF patients undergoing ablation.
Chronic Right Ventricular Pacing Post-Transcatheter Aortic Valve Replacement Attenuates the Benefit on Left Ventricular Function
Background: Conduction abnormality post-transcatheter aortic valve implantation (TAVI) remains clinically significant and usually requires chronic pacing. The effect of right ventricular (RV) pacing post-TAVI on clinical outcomes warrants further studies. Methods: We identified 147 consecutive patients who required chronic RV pacing after a successful TAVI procedure and propensity-matched these patients according to the Society of Thoracic Surgeons (STS) risk score to a control group of patients that did not require RV pacing post-TAVI. We evaluated routine echocardiographic measurements and performed offline speckle-tracking strain analysis for the purpose of this study on transthoracic echocardiographic (TTE) images performed at 9 to 18 months post-TAVI. Results: The final study population comprised 294 patients (pacing group n = 147 and non-pacing group n = 147), with a mean age of 81 ± 7 years, 59% male; median follow-up was 354 days. There were more baseline conduction abnormalities in the pacing group compared to the non-pacing group (56.5% vs. 41.5%. p = 0.01). Eighty-eight patients (61.6%) in the pacing group required RV pacing due to atrioventricular (AV) conduction block post-TAVI. The mean RV pacing burden was 44% in the pacing group. Left ventricular ejection fraction (LVEF) was similar at follow-up in the pacing vs. non-pacing groups (57 ± 13.0%, 59 ± 11% p = 0.31); however, LV global longitudinal strain (−12.7 ± 3.5% vs. −18.8 ± 2.7%, p < 0.0001), LV apical strain (−12.9 ± 5.5% vs. 23.2 ± 9.2%, p < 0.0001), and mid-LV strain (−12.7 ± 4.6% vs. −18.7 ± 3.4%, p < 0.0001) were significantly worse in the pacing vs. non-pacing groups. Conclusions: Chronic RV pacing after the TAVI procedure is associated with subclinical LV systolic dysfunction within 1.5 years of follow-up.
Hand-Held Echocardiography by Advanced Practice Providers in Patients with Congestive Heart Failure
Objectives: The performed hand-held echocardiography (HHE) was evaluated and interpreted by trained advanced practice providers (APPs) on hospitalized CHF patients for image quality and interpretation by comparing with expert echocardiographer and SE findings. Background: Congestive heart failure (CHF) is associated with increased hospital admissions and mortality. While a standard echocardiogram (SE) is the gold standard for cardiac assessment, it is not readily available. Hospitalized CHF patients require rapid assessment for expedited treatment. Methods: Over 6 months, five trained APPs performed HHE on hospitalized CHF patients and interpreted: (a) left ventricular (LV) size, (b) LV ejection fraction (LVEF), and (c) right atrial pressure (RAP). The study echocardiographer reviewed and blindly interpreted the HHE images and compared them with APPs and SE findings. Kappa statistics determined the degree of agreement between APPs and the study echocardiographer’s interpretation of the HHE images and SE. Results: A total of 80 CHF patients (age 73 ± 14 years, 58% males; LVEF (by SE) 45 ± 19%; 36.3% body mass indexes ≥ 30 kg/m2) were enrolled. HHE interpretation by APPs had a good agreement for LVEF (kappa 0.79) with the study echocardiographer and SE (kappa 0.74) and a good agreement for RAP (kappa 0.67) with the study echocardiographer. The correlation between the absolute LVEF interpretation by the study echocardiographer on HHE and SE was r = 0.88 (p < 0.0001). Conclusions: Trained APPs obtained diagnostic-quality HHE images and interpreted the LV function and RAP in CHF patients in good agreement with the study echocardiographer. LVEF by HHE correlated with LVEF by SE. Our study suggests trained APPs can use HHE to evaluate LVEF and RAP in CHF patients, leading to expedited and optimized treatment.
Abstract 11685: Effects of Pectus Excavatum Surgical Repair on Cardiac Volumes and Systolic Function as Assessed by 3D Transesophageal Echocardiography
Introduction: The consequences of external cardiovascular compression and cardiac displacement from pectus excavatum (PEx) are debated. The complex geometry of the right (RV) and left ventricle (LV) along with distortion from the extrinsic chest deformity pose significant limitations to reliable assessment of LV and RV volumes and function using transthoracic 2D-echocardiography in this population. Hypothesis: A 3D-echocardiography approach can reliably assess the effects of external cardiac compression and the benefits of surgical correction on RV and LV function in PEx patients. Methods: Adult patients undergoing minimally invasive repair of PEx between Oct-2021 and Feb-2023 were included in this prospective study. Intraoperative transesophageal (TEE) 6 beat full volume video loops incorporating LV and RV were captured and compared before and after surgical correction of the PEx. TomTec Software® was used for offline 3D/4D reconstruction ( Figure 1 shows changes in 3D RV and LV shape pre- and post-surgery). Result: The study included 102 patients (mean age of 32.1 ±11.8 years; Haller index 4.9 ±2.5; 60.8% males). Post PEx repair, there was a significant (p<0.001) increase in the 3D RV volumes, RV ejection fraction (EF), RV stroke volume and RV strain ( Figure 1 ). Additionally, there was a significant improvement in 3D LVEF, 3D LV strain (longitudinal and circumferential), LV twist, and torsion ( Figure 1 ). Conclusion: In this PEx cohort, 3D/4D TEE imaging demonstrated significant increases in RV volumes and in RV and LV systolic function after surgical repair. These findings support the negative cardiovascular consequences of PEx compression and benefits of surgical repair.
New pathological illuminations on 3D transillumination transesophageal echocardiography imaging
AbstractThe use of 3D technology has significantly improved the diagnostic accuracy of echocardiography by overcoming the limitation of 2D echocardiography. Transillumination 3D image post processing technique enhances shadows and contrast of cardiac structures with a movable virtual light source improving further the clarity and detail provided by conventional 3D imaging. In this report, we present 3 cases, one of mobile atherosclerotic aortic root plaque, another of small thrombi on ICD lead, and a third case of bicuspid aortic valve perforation due to infective endocarditis in whom TEE 3D transillumination further improved the diagnostic quality of conventional 3D imaging and lead to accurate clinical diagnosis.