Back to Authors

Griessenauer, Christoph J.

https://orcid.org/0000-0002-2952-3812

Mayo Clinic

Christian Doppler Klinik

Citations 38

Flow Diversion for Middle Cerebral Artery Aneurysms: An International Cohort Study
Diestro, Jose Danilo Bengzon , Adeeb, Nimer , Dibas, Mahmoud , Boisseau, William , Harker, Pablo , Brinjikji, Waleed , Xiang, Sishi, Joyce, Evan, Shapiro, Maksim , Raz, Eytan , Pickett, Gwynedd E. , Alotaibi, Naif M. , Regenhardt, Robert W. , Spears, Julian , Burkhardt, Jan‐Karl , Hafeez, Muhammad Ubaid , Kan, Peter , Nossek, Erez , Zhang, Hongqi , Rinaldo, Lorenzo , Stapleton, Christopher J. , Rabinov, James D. , Patel, Aman B. , Marotta, Thomas R. , Dmytriw, Adam A. , Burkhardt, Jan-Karl , Kan, Peter , Rinaldo, Lorenzo , Lanzino, Giuseppe , Dmytriw, Adam A , Dibas, Mahmoud , Diestro, Jose Danilo B , Harker, Pablo , Regenhardt, Robert W , Hafeez, Muhammad U , Burkhardt, Jan‐Karl , Parra-Fariñas, Carmen , Bernstock, Joshua D. , Griessenauer, Christoph J. , Grandhi, Ramesh , Taussky, Philipp , Hong, Tao , Lanzino, Giuseppe , Roy, Daniel C.

Neurosurgery | September 8, 2021 | Volume: 89 | Issue: 6 | Pages: 1112-1121

10.1093/neuros/nyab365 Get It

Abstract BACKGROUND Open surgery has traditionally been preferred for the management of bifurcation middle cerebral artery (MCA) aneurysms. Flow diverting stents present a novel endovascular strategy for aneurysm treatment. OBJECTIVE To add to the limited literature describing the outcomes and complications in the use of flow diverters for the treatment of these complex aneurysms. METHODS This is a multicenter retrospective review of MCA bifurcation aneurysms undergoing flow diversion. We assessed post-treatment radiological outcomes and both thromboembolic and hemorrhagic complications. RESULTS We reviewed the outcomes of 54 aneurysms treated with flow diversion. Four (7.4%) of the aneurysms had a history of rupture (3 remote and 1 acute). Fourteen (25.9%) of the aneurysms already underwent either open surgery or coiling prior to flow diversion. A total of 36 out of the 45 aneurysms (80%) with available follow-up data had adequate aneurysm occlusion with a median follow-up time of 12 mo. There were no hemorrhagic complications but 16.7% (9/54) had thromboembolic complications. CONCLUSION Flow diverting stents may be a viable option for the endovascular treatment of complex bifurcation MCA aneurysms. However, compared to published series on the open surgical treatment of this subset of aneurysms, flow diversion has inferior outcomes and are associated with a higher rate of complications.
Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study
Enríquez-Marulanda, Alejandro , Xiang, Sissi, Zhang, Hongqi , Waqas, Muhammad , Tutino, Vincent M. , Siddiqui, Adnan H. , Ogilvy, Christopher S. , Ulfert, Christian , Möhlenbruch, Markus , Renieri, Leonardo , Limbucci, Nicola , Burkhardt, Jan‐Karl , Kan, Peter , Rinaldo, Lorenzo , Brinjikji, Waleed , Spears, Julian , Broussalis, Erasmia , Koçer, Naci , Sonnberger, Michael , Engelhorn, Tobias , Ghuman, Mandeep S. , Salehani, Arsalaan , Harrigan, Mark R. , Radovanovic, Ivan , Chen, Karen , Aziz‐Sultan, Mohammad Ali , Ghorbani, Mohammad , Schirmer, Clemens M. , Goren, Oded , Dalal, Shamsher , Koch, Matthew J. , Stapleton, Christopher J. , Patel, Aman B. , Finkenzeller, Thomas , Holtmannspötter, Markus, Buhk, Jan Hendrik, Foreman, Paul M. , Cress, Marshall C. , Hirschl, Robert , Reith, W. , Janssen, Hendrik , Marotta, Thomas R. , Dmytriw, Adam A. , Waqas, Muhammad , Siddiqui, Adnan H , Levy, Elad I , Thomas, Ajith J , Renieri, Leonardo , Parra-Fariñas, Carmen , Rinaldo, Lorenzo , Brinjikji, Waleed , Müller-Thies-Broussalis, Erasmia , Killer-Oberpfalzer, Monika , Koch, Matthew J , Simgen, Andreas , Janssen, Hendrik , Marotta, Thomas R , Dmytriw, Adam A , Tutino, Vincent M , Schirmer, Clemens M , Ulfert, Christian , Limbucci, Nicola , Ogilvy, Christopher S , Griessenauer, Christoph J. , Hong, Tao , Taussky, Philipp , Grandhi, Ramesh , Levy, Elad I. , Lanzino, Giuseppe , Işlak, Civan , Yang, Victor X. D. , Mendes Pereira, Vitor , Krings, Timo , Matouk, Charles

Journal of NeuroInterventional Surgery | July 1, 2020 | Volume: 13 | Issue: 2 | Pages: 153-158

10.1136/neurintsurg-2020-016055 Get It

Abstract Background Flow diversion is a common endovascular treatment for cerebral aneurysms, but studies comparing different types of flow diverters are scarce. Objective To perform a propensity score matched cohort study comparing the Pipeline Embolization Device (PED) and Flow Redirection Intraluminal Device (FRED) for posterior circulation aneurysms. Methods Consecutive aneurysms of the posterior circulation treated at 25 neurovascular centers with either PED or FRED were collected. Propensity score matching was used to control for age, duration of follow-up imaging, adjunctive coiling, and aneurysm location, size, and morphology; previously ruptured aneurysms were excluded. The two devices were compared for the following outcomes: procedural complications, aneurysm occlusion, and functional outcome. Results A total of 375 aneurysms of the posterior circulation were treated in 369 patients. The PED was used in 285 (77.2%) and FRED in 84 (22.8%) procedures. Aneurysms treated with the PED were more commonly fusiform and larger than those treated with FRED. To account for these important differences, propensity score matching was performed resulting in 33 PED and FRED unruptured aneurysm pairs. No differences were found in occlusion status and neurologic thromboembolic or hemorrhagic complications between the two devices. The proportion of patients with favorable functional outcome was higher with FRED (100% vs 87.9%, p=0.04). Conclusion Comparative analysis of PED and FRED for the treatment of unruptured posterior circulation aneurysms did not identify significant differences in aneurysm occlusion or neurologic complications. Variations in functional outcomes warrant additional investigations.
Experience With the Pipeline Embolization Device for Posterior Circulations Aneurysms: A Multicenter Cohort Study
Enríquez-Marulanda, Alejandro , Biswas, Arundhati , Xiang, Sissi, Rinaldo, Lorenzo , Brinjikji, Waleed , Burkhardt, Jan‐Karl , Kan, Peter , Ghuman, Mandeep S. , Chen, Karen , Aziz‐Sultan, Mohammad Ali , Ghorbani, Mohammad , Schirmer, Clemens M. , Goren, Oded , Dalal, Shamsher , Broussalis, Erasmia , Koch, Matthew J. , Stapleton, Christopher J. , Patel, Aman B. , Foreman, Paul M. , Cress, Marshall C. , Hirschl, Robert , Zhang, Hongqi , Dmytriw, Adam A. , Rinaldo, Lorenzo , Dmytriw, Adam A , Schirmer, Clemens M , Griessenauer, Christoph J. , Taussky, Philipp , Grandhi, Ramesh , Hong, Tao , Lanzino, Giuseppe , Yang, Victor X. D. , Killer-Oberpfalzer, Monika , Krings, Timo

Neurosurgery | June 5, 2020 | Volume: 87 | Issue: 6 | Pages: 1252-1261

10.1093/neuros/nyaa277 Get It

Abstract BACKGROUND The Pipeline Embolization Device (PED; Medtronic) has been used off-label for the treatment of challenging posterior circulation aneurysms. Data on this modality are primarily limited to small retrospective single-center series. OBJECTIVE To assess safety and efficacy of this treatment by establishing an international, multicenter collaboration. METHODS Consecutive posterior circulation aneurysms treated with the PED from 2012 to 2019 across 11 neurovascular centers were retrospectively reviewed. Baseline demographics, aneurysm and treatment characteristics, complications, occlusion status, and functional outcome were assessed. RESULTS There were 149 posterior circulation aneurysms treated with PED in 146 patients. A total of 24 (16.4%) patients presented with subarachnoid hemorrhage. Most aneurysms were dissecting/blister (36.2%) in morphology, followed by saccular (35.6%) and fusiform (28.2%). The most common locations were the vertebral (51.7%) and basilar arteries (22.8%). Complete or near-complete occlusion (>90%) was achieved in 90.9% of aneurysms at a median follow-up of 12 mo. Dissecting/blister aneurysms were most likely to occlude ( P = .06). Symptomatic neurologic complications occurred in 9.4% of aneurysms, associated with larger size, ruptured presentation, presentations with brain stem compression, cranial nerve palsy, or stroke. Favorable functional outcome (modified Rankin Score 0-2) was achieved in 86.2% of patients. There were 6 fatalities of which 4 occurred in aneurysmal subarachnoid hemorrhage patients. CONCLUSION This multicenter study shows that PED for the treatment of posterior circulation is preferentially used for the treatment of fusiform and dissecting/blister aneurysm morphologies. Despite the challenges presented by these less-common morphologies, flow diversion may be performed with a neurologic complication rate of about 10% and favorable long-term aneurysm occlusion rates.
Alfred W. Adson (1887–1951): his contributions to surgery for tumors of the spine and spinal cord in the context of spinal tumor surgery in the late 19th and early 20th centuries
Griessenauer, Christoph J. , Tubbs, R. Shane , Raborn, Joel, Mortazavi, Martin M., Shoja, Mohammadali M. , Boes, Christopher J. , Lanzino, Giuseppe , Griessenauer, Christoph J

Journal of Neurosurgery: Spine | October 18, 2013 | Volume: 19 | Issue: 6 | Pages: 750-758

10.3171/2013.9.spine13220 Get It

Alfred W. Adson was a pioneer in the field of neurosurgery. He described operations for a variety of neurosurgical diseases and developed surgical instruments. Under his leadership the Section of Neurological Surgery at the Mayo Clinic was established and he functioned as its first chair. Adson's contributions to the understanding of spinal and spinal cord tumors are less well known. This article reviews related medical records and publications and sets his contributions in the context of the work of other important pioneers in spinal tumor surgery at the time.
Wireless Instantaneous Neurotransmitter Concentration System: electrochemical monitoring of serotonin using fast-scan cyclic voltammetry—a proof-of-principle study
Griessenauer, Christoph J. , Chang, Su-Youne , Tye, Susannah J. , Kimble, Christopher J., Bennet, Kevin E. , Garris, Paul A. , Lee, Kendall H. , Tye, Susannah J , Griessenauer, Christoph J

Journal of Neurosurgery | April 23, 2010 | Volume: 113 | Issue: 3 | Pages: 656-665

10.3171/2010.3.jns091627 Get It

Object The authors previously reported the development of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for measuring dopamine and suggested that this technology may be useful for evaluating deep brain stimulation–related neuromodulatory effects on neurotransmitter systems. The WINCS supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially resolved neurotransmitter measurements. The FSCV parameters used to establish WINCS dopamine measurements are not suitable for serotonin, a neurotransmitter implicated in depression, because they lead to CFM fouling and a loss of sensitivity. Here, the authors incorporate into WINCS a previously described N-shaped waveform applied at a high scan rate to establish wireless serotonin monitoring. Methods Optimized for the detection of serotonin, FSCV consisted of an N-shaped waveform scanned linearly from a resting potential of +0.2 to +1.0 V, then to −0.1 V and back to +0.2 V, at a rate of 1000 V/second. Proof-of-principle tests included flow injection analysis and electrically evoked serotonin release in the dorsal raphe nucleus of rat brain slices. Results Flow cell injection analysis demonstrated that the N waveform, applied at a scan rate of 1000 V/second, significantly reduced serotonin fouling of the CFM, relative to that observed with FSCV parameters for dopamine. In brain slices, WINCS reliably detected subsecond serotonin release in the dorsal raphe nucleus evoked by local high-frequency stimulation. Conclusions The authors found that WINCS supported high-fidelity wireless serotonin monitoring by FSCV at a CFM. In the future such measurements of serotonin in large animal models and in humans may help to establish the mechanism of deep brain stimulation for psychiatric disease.
Wireless Instantaneous Neurotransmitter Concentration System–based amperometric detection of dopamine, adenosine, and glutamate for intraoperative neurochemical monitoring
Agnesi, Filippo , Tye, Susannah J. , Bledsoe, Jonathan M., Griessenauer, Christoph J. , Kimble, Christopher J., Sieck, Gary C. , Bennet, Kevin E. , Garris, Paul A. , Blaha, Charles D. , Lee, Kendall H. , Sieck, Gary , Tye, Susannah J , Griessenauer, Christoph J , Blaha, Charles

Journal of Neurosurgery | May 8, 2009 | Volume: 111 | Issue: 4 | Pages: 701-711

10.3171/2009.3.jns0990 Get It

Object In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. Methods The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme–linked electrode to measure glutamate; and 3) a multiple enzyme–linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. Results The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. Conclusions By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.