Abstract BACKGROUND Open surgery has traditionally been preferred for the management of bifurcation middle cerebral artery (MCA) aneurysms. Flow diverting stents present a novel endovascular strategy for aneurysm treatment. OBJECTIVE To add to the limited literature describing the outcomes and complications in the use of flow diverters for the treatment of these complex aneurysms. METHODS This is a multicenter retrospective review of MCA bifurcation aneurysms undergoing flow diversion. We assessed post-treatment radiological outcomes and both thromboembolic and hemorrhagic complications. RESULTS We reviewed the outcomes of 54 aneurysms treated with flow diversion. Four (7.4%) of the aneurysms had a history of rupture (3 remote and 1 acute). Fourteen (25.9%) of the aneurysms already underwent either open surgery or coiling prior to flow diversion. A total of 36 out of the 45 aneurysms (80%) with available follow-up data had adequate aneurysm occlusion with a median follow-up time of 12 mo. There were no hemorrhagic complications but 16.7% (9/54) had thromboembolic complications. CONCLUSION Flow diverting stents may be a viable option for the endovascular treatment of complex bifurcation MCA aneurysms. However, compared to published series on the open surgical treatment of this subset of aneurysms, flow diversion has inferior outcomes and are associated with a higher rate of complications.
Crossing the Carotid Siphon: Techniques to Facilitate Distal Access in Tortuous Anatomy: 2-Dimensional Operative Video
Abstract As capabilities for endovascular treatment of intracranial vascular pathologies continue to expand, the need for access to the distal internal carotid artery with rigid support catheter systems continues to increase. One of the dominant factors limiting this access is patient anatomy, specifically vessel tortuosity. Increased tortuosity of the carotid siphon is a frequently encountered anatomic variant and may complicate endovascular procedures in adults and children. 1,2 Failed attempts to navigate the carotid siphon with a distal access catheter carry a risk of vessel injury and treatment failure. For this reason, techniques that aid in supporting safe advancement of a distal access catheter across a tortuous carotid siphon are essential. 3,4 In this video, we demonstrate 2 ways in which this may be accomplished. The first technique uses a larger diameter microcatheter, such as the AXS Offset catheter (Stryker, Kalamazoo, Michigan), to increase support for the distal access catheter, while the second uses a buddy wire technique to accomplish this increased support. Both of these techniques can help increase the safety of navigating a tortuous carotid siphon and increase the likelihood of successful treatment. The procedures shown were performed with the informed consent of the patients.