Perfusion Territory of Embolized Coronary Artery Vasa Vasorum
Moritz, Regina, Eaker, Diane R., Anderson, Jill , Kline, Timothy L. , Jorgensen, Steven M., Ritman, Erik L.

The FASEB Journal | June 15, 2021 | Volume: 24 | Issue: S1 | Pages: No page available

10.1096/fasebj.24.1_supplement.1034.7 Get It

Occlusion of coronary vasa vasorum (VV) leads to hypoperfusion of the arterial vessel wall (AVW) possibly resulting in impaired solute transport. We hypothesize that high cholesterol (HC) facilitates development of atherogenesis in hypoperfused areas. Swine (40) underwent injection of gold‐coated μspheres (100μm) in left coronary artery. After the procedure 13 swine were studied immediately, 13 were fed a standard (C) and 14 a HC diet for 3 months prior to study. The LADs were harvested and snap‐frozen (cryo micro‐CT scanning). Hypoperfused areas in the AVW were defined by local reduction of CT‐values. The distance of μsphere to lumen (x) was measured, and foam/fat cells/mm 2 (f/fc) in hypoperfused and perfused areas were counted using histology. Linear relationship between x and hypoperfused AVW. In HC the f/fc # in media of hypoperfused areas is higher than in C (p=0.001). In HC f/fc # is higher in hypoperfused AVW areas compared to adjacent perfused areas (p<0.05). In C there is no difference in f/fc # between hypoperfused and perfused areas (p=0.92). In C and HC the f/fc # in intima of perfused, as well as in hypoperfused, areas is not different (p=0.9/0.5). Occlusion of VV leads to increased susceptibility of hypoperfused AVW areas for precursors of atherosclerosis with HC diet. The linear relationship of hypoperfused area to μsphere distance suggests that VV function as a plexus rather than a vascular tree. This study was supported by NIH grant HL065342.
Evaluation of a photon counting Medipix3RX cadmium zinc telluride spectral x-ray detector
Marsh, Jeffrey F., Jorgensen, Steven M., Rundle, David S., Vercnocke, Andrew J. , Butler, Philip H. , Ritman, Erik L., Leng, Shuai , Butler, Philip H , McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | December 4, 2018 | Volume: 5 | Issue: 04 | Pages: 1

10.1117/1.jmi.5.4.043503 Get It

Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT
Jorgensen, Steven M., Demirkaya, Omer, Ritman, Erik L.

American Journal of Physiology-Heart and Circulatory Physiology | December 22, 2017 | Volume: 275 | Issue: 3 | Pages: H1103-H1114

10.1152/ajpheart.1998.275.3.h1103 Get It

A microcomputed tomography (micro-CT) scanner, which generates three-dimensional (3-D) images consisting of up to a billion cubic voxels, each 5–25 μm on a side, and which has isotropic spatial resolution, is described. Its main components are a spectroscopic X-ray source that produces selectable primary emission peaks at ∼9, 18, or 25 keV and a fluorescing thin crystal plate that is imaged (at selectable magnification) with a lens onto a 2.5 × 2.5-cm, 1,024 × 1,024-pixel, charge-coupled device (CCD) detector array. The specimen is positioned close to the crystal and is rotated in 721 equiangular steps around 360° between each X-ray exposure and its CCD recording. Tomographic reconstruction algorithms, applied to these recorded images, are used to generate 3-D images of the specimen. The system is used to scan isolated, intact, fixed rodent organs (e.g., heart or kidney) with the image contrast of vessel lumens enhanced with contrast medium. 3-D image display and analysis are used to address physiological questions about the internal structure-to-function relationships of the organs.
Measuring arterial wall perfusion using photon-counting computed tomography (CT): improving CT number accuracy of artery wall using image deconvolution
Rajendran, Kishore , Jorgensen, Steven M., Anderson, Jill , Halaweish, Ahmed F., Abdurakhimova, Dilbar, Ritman, Erik L., Anderson, Jill L, McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | December 8, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.044006 Get It

Detection of increased vasa vasorum in artery walls: improving CT number accuracy using image deconvolution
Rajendran, Kishore , Jorgensen, Steven M., Abdurakhimova, Dilbar, Ritman, Erik L., Leng, Shuai , McCollough, Cynthia H. , Rajendran, Kishore

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323O

10.1117/12.2255676 Get It

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system
Yu, Zhicong , Halaweish, Ahmed F., Kappler, S. , Hähn, Katharina, Henning, André , Li, Zhoubo , Lane, John I. , Levin, David L. , Jorgensen, Steven M., Ritman, Erik L., Lane, John , Jorgensen, Steven, Ritman, Erik, McCollough, Cynthia, Leng, Shuai , McCollough, Cynthia H. , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 Get It

Arterial wall perfusion measured with photon counting spectral x-ray CT
Jorgensen, Steven M., Korinek, Mark J., Vercnocke, Andrew J. , Anderson, Jill , Halaweish, Ahmed F., Ritman, Erik L., Anderson, Jill L, Korinek, Mark, Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | October 4, 2016 | Volume: 9967 | Issue: No issue available | Pages: 99670B

10.1117/12.2238817 Get It

Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector
Jorgensen, Steven M., Vercnocke, Andrew J. , Rundle, David S., Butler, Philip H. , Ritman, Erik L., McCollough, Cynthia H.

SPIE Proceedings | October 3, 2016 | Volume: 9969 | Issue: No issue available | Pages: 99690J

10.1117/12.2236501 Get It

Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Yu, Zhicong , Jorgensen, Steven M., Li, Zhoubo , Gutjahr, Ralf , Chen, Baiyu , Halaweish, Ahmed F., Kappler, S. , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 Get It

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels
Gutjahr, Ralf , Halaweish, Ahmed F., Yu, Zhicong , Yu, Lifeng , Li, Zhoubo , Jorgensen, Steven M., Ritman, Erik L., Kappler, S. , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Investigative Radiology | January 27, 2016 | Volume: 51 | Issue: 7 | Pages: 421-429

10.1097/rli.0000000000000251 Get It

Objectives The purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to determine clinical feasibility using human cadavers. Materials and Methods A research dual-source PCD-CT scanner was used, where the “A” tube/detector subsystem used an EID and the “B” tube/detector subsystem used a PCD. Iodine CNR was measured in 4 anthropomorphic phantoms, simulating 4 patient sizes, at 4 tube potential settings. After biospecimen committee approval, PCD scans were performed on a fresh-frozen human head and a whole-body cadaver using clinical dose rates. Scans were repeated using the EID and identical parameters, and qualitative side-by-side comparisons were performed. Results For the same photon fluence, phantom measurements demonstrated a mean increase in CNR of 11%, 23%, 31%, 38% for the PCD system, relative to the EID system, at 80, 100, 120, and 140 kV, respectively. Photon-counting detector CT additionally provided energy-selective imaging, where low- and high-energy images reflected the energy dependence of the iodine signal. Photon-counting detector images of cadaveric anatomy demonstrated decreased beam hardening and calcium blooming in the high-energy bin images and increased contrast in the low-energy bins images relative to the EID images. Threshold-based PCD images were qualitatively deemed equivalent in other aspects. Conclusions The evaluated research PCD-CT system was capable of clinical levels of image quality at clinical dose rates. It further provided improved CNR relative to state-of-the-art EID-CT. The energy-selective bin images provide further opportunity for dual-energy and multienergy analyses.