Reinterpretation of outside imaging and review at hepatobiliary tumor board: impact on diagnosis and management of patients with hepatobiliary neoplasms
Abstract Objectives: Radiologist participation in multidisciplinary tumor board can be time-consuming and demanding, requiring substantial preparation. Anecdotally radiologist participation is felt to help identify discrepancies in previous interpretations; however, there are limited data assessing the actual impact of their tumor board review on patient management. This prospective study aims to evaluate how the reinterpretation of outside imaging and review at hepatobiliary tumor board (HBTB) affects the diagnosis and management of patients with hepatobiliary neoplasms. Methods: This prospective analysis included all patients presented at the weekly HBTB between 6/13/2023 - 6/25/2024. One radiologist reviewed the available reports of outside imaging, the local reinterpretation of outside imaging, the updated local imaging, and documented conclusions from discussion of the case at HBTB. HBTB included 4 radiologists who had reviewed each case. Discrepancies (presence/absence, number, and reasons for) were recorded. When discrepancies occurred, the impact on patient management (5-point Likert scale) was determined by two of the radiologists present at the HBTB in consensus, with input from clinicians if needed. A six-month follow-up was performed to confirm suspected diagnoses. Results: 208 cases (128 males, 104 chronic liver disease patients) were presented at HBTB. Disagreements in the detection or characterization of lesions were found in 59/208 (28.4%) of cases. A change in management occurred in 38/59 (64.6%) of these discrepant cases. In cases with recorded discrepancies in which follow-up confirmation was available, the final interpretation was confirmed in 34/41 (82.9%) of cases. Conclusion: Our study found a discrepant interpretation in nearly one-third of cases presented at a weekly HBTB and a resultant change in management in 65% of those cases. These findings highlight the importance of reinterpretation of prior imaging studies and the presence of radiologists at HBTB to guide optimal patient management.
Effect of endoscopic sleeve gastroplasty on gastric emptying, motility and hormones: a comparative prospective study
Objective Endoscopic sleeve gastroplasty (ESG) has gained global adoption but our understanding of its mechanism(s) of action and durability of efficacy is limited. We sought to determine changes in gastric emptying (GE), gastric motility (GM), hormones and eating behaviours after ESG. Design A priori-designed single-centre substudy of a large US randomised clinical trial, adults with obesity were randomised to ESG or lifestyle interventions (LS) alone. We measured GE, hormones and weight loss and assessed eating behaviours. In a subset of ESG patients, we assessed GM. The primary outcome was the change in T1/2 (min) at 3 months, and secondary outcomes were changes in weight, GE, GM, hormones and eating behaviours. We used t-test analyses and regression to determine the association between GE and weight loss. Results 36 (ESG=18; LS=18) participated in this substudy. Baseline characteristics were similar between the two groups. At 3 months, T1/2 was delayed in the ESG group (n=17) compared with the LS group (n=17) (152.3±47.3 vs 89.1±27.9; p<0.001). At 12 months, T1/2 remained delayed in the ESG group (n=16) vs control group (n=14) (137±37.4 vs 90.1±23.4; p<0.001). Greater delays in GE at 3 months were associated with greater weight loss. GM was preserved and fasting ghrelin, glucagon-like peptide 1 and polypeptide YY significantly increased 18 months after ESG. Conclusion ESG promotes weight loss through several key mechanistic pathways involving GE and hormones while preserving GM. These findings further support clinical adoption of this technique for the management of obesity. Trial registration number NCT03406975.
Virtual pelvic anatomy simulator improved medical student comprehension of pelvic anatomy
Given curricular time constraints, the complex relationships of pelvic viscera can be difficult for students to master. We developed an interactive 3‐dimensional virtual pelvic model using high‐resolution 3‐Telsa magnetic resonance and 64‐slice computed tomographic datasets of a healthy male. The aim of this study was to determine if use of this curricular adjunct was associated with improved comprehension of pelvic anatomy as measured by a 33 item test. The software was distributed to 47 first year medical students during their 3‐day pelvic anatomy curriculum. Forty students (85%) completed the test. Students used the software for a median of 15 (interquartile range [IQR] 10 – 22) minutes; total minutes studying pelvic anatomy was 240 (IQR 125 – 525) minutes. Minutes of software use was strongly associated with the total study time (p<0.0001). On univariate analysis, pelvic anatomy test scores were associated with both minutes of software use (p=0.05) and total study time (p=0.04). On multivariate analysis both software use (p=0.12) and total study time (p=0.08) trended towards significant association with test scores. Most students used the software alongside books to aid in initial spatial orientation to the pelvis. Virtual anatomy software can be a valuable, effective adjunct to traditional anatomy education. Source of funding: Mayo Foundation for Medical Education and Research. Grant Funding Source : Source of funding: Mayo Foundation for Medical Education and Research.
Randomized Trial of Spheroid Reservoir Bioartificial Liver in Porcine Model of Posthepatectomy Liver Failure
Acute liver failure (ALF) is a catastrophic condition that can occur after major liver resection. The aim of this study was to determine the effects of the spheroid reservoir bio‐artificial liver (SRBAL) on survival, serum chemistry, and liver regeneration in posthepatectomy ALF pigs. Wild‐type large white swine (20 kg‐30 kg) underwent intracranial pressure (ICP) probe placement followed by 85% hepatectomy. Computed tomography (CT) volumetrics were performed to measure the extent of resection, and at 48 hours following hepatectomy to assess regeneration of the remnant liver. Animals were randomized into three groups based on treatment delivered 24‐48 hours after hepatectomy: Group1—standard medical therapy (SMT, n = 6); Group2—SMT plus bio‐artificial liver treatment using no hepatocytes (0 g, n = 6); and Group3—SMT plus SRBAL treatment using 200 g of primary porcine hepatocyte spheroids (200 g, n = 6). The primary endpoint was survival to 90 hours following hepatectomy. Death equivalent was defined as unresponsive grade 4 hepatic encephalopathy or ICP greater than 20 mmHg with clinical evidence of brain herniation. All animals in both (SMT and 0 g) control groups met the death equivalent before 51 hours following hepatectomy. Five of 6 animals in the 200‐g group survived to 90 hours ( P < 0.01). The mean ammonia, ICP, and international normalized ratio values were significantly lower in the 200‐g group. CT volumetrics demonstrated increased volume regeneration at 48 hours following hepatectomy in the 200‐g group compared with the SMT ( P < 0.01) and 0‐g (P < 0.01) groups. Ki‐67 staining showed increased positive staining at 48 hours following hepatectomy ( P < 0.01). Conclusion: The SRBAL improved survival, reduced ammonia, and accelerated liver regeneration in posthepatectomy ALF. Improved survival was associated with a neuroprotective benefit of SRBAL therapy. These favorable results warrant further clinical testing of the SRBAL.
Clinical Benefit of Capsule Endoscopy in Crohn’s Disease: Impact on Patient Management and Prevalence of Proximal Small Bowel Involvement
Gastric emptying, accommodation, and motility can be quantified with magnetic resonance imaging (MRI). The first step in image analysis entails segmenting the stomach from surrounding structures, usually by a time-consuming manual process. We have developed a semiautomated process to segment and measure gastric volumes with MRI. Gastric images were acquired with a three-dimensional gradient echo MRI sequence at 5, 10, 20, and 30 min after ingestion of a liquid nutrient (Ensure, 296 ml) labeled with gadolinium in 20 healthy volunteers and 29 patients with dyspeptic symptoms. The agreement between gastric volumes measured by manual segmentation and our new semiautomated algorithm was assessed with Lin's concordance correlation coefficient (CCC) and the Bland Altman test. At 5 min after a meal, food volumes measured by manual (352 ± 4 ml) and semiautomated (346 ± 4 ml) techniques were correlated {CCC[95% confidence interval (CI)] 0.70 (0.52, 0.81)}; air volumes measured by manual (88 ± 6 ml) and semiautomated (84 ± 6 ml) techniques were also correlated [CCC (95% CI) 0.89 (0.82, 0.94)]. Findings were similar at subsequent time points. The Bland Altman test was not significant. The time required for semiautomated segmentation ranged from an average of 204 s for the 5-min images to 233 s for the 20-min images. These times were appreciably smaller than the typical times of many tens of minutes, even hours, required for manual segmentation. To conclude, a semiautomated process can measure gastric food and air volume using MRI with comparable accuracy and far better efficiency than a manual process.