Abstract Background Magnetic Resonance‐guided Radiation Therapy (MRgRT) systems are increasingly used in clinical practice, necessitating a dedicated dosimetry protocol to address the challenges posed by the presence of strong magnetic fields. Purpose AAPM TG351 introduces a reference dosimetry protocol for external beam MRgRT systems, aligning with AAPM TG51 reports and incorporating elements from the IAEA TRS398 code of practice. Methods The protocol offers practical guidance on beam quality and dosimetry setup in the presence of strong magnetic fields. It reviews relevant literature to identify reference‐class chambers suitable for external beam MRgRT systems and determines their beam quality conversion and other relevant correction factors through a detailed analysis of available data and associated uncertainties. Results AAPM TG351 offers a comprehensive dosimetry protocol for external beam MRgRT systems, addressing the unique challenges posed by the presence of magnetic fields. It includes detailed guidance for measurement setups, a list of reference‐class chambers appropriate for reference dosimetry in MRgRT systems, and updated beam quality conversion and correction factors. Additionally, the protocol presents an in‐depth analysis of the uncertainty budget, identifying key contributors and providing strategies to minimize uncertainties, thereby enhancing clinical accuracy and reliability. Conclusions This protocol provides a practical, evidence‐based reference for medical physicists conducting reference dosimetry in external beam MRgRT systems.
Characterization of LiF TLD‐100 in carbon ion beams for remote audits
Abstract Background A passive dosimeter framework for the measurement of dose in carbon ion beams has yet to be characterized or implemented for regular use. Purpose This work determined the dose calculation correction factors for absorbed dose in thermoluminescent dosimeters (TLDs) in a therapeutic carbon ion beam. TLD could be a useful tool for remote audits, particularly in the context of clinical trials as new protocols are developed for carbon ion radiotherapy. Methods TLD‐100 were irradiated in a carbon ion beam at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia, Italy. The dose correction factors for linearity, fading, and beam quality were characterized. Fading was characterized from 5 to 100 days post‐irradiation. For linearity, the TLDs were irradiated to absorbed doses ranging from 1 to 15 Gy in both the entrance of a high‐energy pristine carbon ion peak and the center of a 2 cm spread‐out Bragg peak. For beam quality, the TLD was irradiated to the same absorbed dose (3 Gy) in several pristine carbon ion Bragg peaks, as well as in several spread‐out Bragg peaks. Each correction factor was calculated and compared to photon correction factors. The correction factors were also compared between high and low dose‐averaged linear energy transfer (LET D ) in the carbon ion beams. The absorbed dose was compared between ion chamber and TLD‐100 in the several tissue substitute phantom materials, applying the carbon ion TLD correction factors. Results There was no statistically significant difference in the TLD fading correction factor between photons, low LET D carbon ion beams, or high LET D carbon ion beams. The TLD linearity correction factor did differ between photons, low LET D carbon ions, and high LET D carbon ions. The beam quality correction factor was large and changed linearly with LET D . The overall uncertainty of the carbon ion absorbed dose calculation was 3.9% at the one‐sigma level, driven largely by a 3.5% uncertainty in the beam quality correction. TLD measurements were within 1.2% of ion chamber measurements in the phantom material for polyethylene, solid water (Gammex and Sun Nuclear), acrylic, blue water, and techtron HPV. TLD measurements in balsa wood were within 3.0% and cork was 6.6% low compared to ion chamber. Conclusion TLD‐100 can be used for passive dosimetry in a therapeutic carbon ion beam. Importantly, the linearity and beam quality correction factors are both different from photon therapy, and dependent on LET D of the carbon ion beam. This opens the possibility of TLD use for carbon ion output audits, phantom audits, and in vivo dose measurements, but may be subject to more complicated management and slightly larger uncertainties than are achieved in photon beams.
OSLD nanoDot characterization for carbon radiotherapy dosimetry
Abstract Objective . This study characterized optically-stimulated luminescent dosimeter (OSLD) nanoDots for use in a therapeutic carbon beam using the Imaging and Radiation Oncology Core (IROC) framework for remote output verification. Approach . The absorbed dose correction factors for OSLD (fading, linearity, beam quality, angularity, and depletion), as defined by AAPM TG 191, were characterized for carbon beams. For the various correction factors, the effect of linear energy transfer (LET) was examined by characterizing in both a low and high LET setting. Main results . Fading was not statistically different between reference photons and carbon, nor between low and high LET beams; thus, the standard IROC-defined exponential function could be used to characterize fading. Dose linearity was characterized with a linear fit; while low and high LET carbon linearity was different, these differences were small and could be rolled into the uncertainty budget if using a single linearity correction. A linear fit between beam quality and dose-averaged LET was determined. The OSLD response at various angles of incidence was not statistically different, thus a correction factor need not be applied. There was a difference in depletion between low and high LET irradiations in a primary carbon beam, but this difference was small over the standard five readings. The largest uncertainty associated with the use of OSLDs in carbon was because of the k Q correction factor, with an uncertainty of 6.0%. The overall uncertainty budget was 6.3% for standard irradiation conditions. Significance . OSLD nanoDot response was characterized in a therapeutic carbon beam. The uncertainty was larger than for traditional photon applications. These findings enable the use of OSLDs for carbon absorbed dose measurements, but with less accuracy than conventional OSLD audit programs.
Technical note: Radiological clinical equivalence for phantom materials in carbon ion therapy
AbstractPurposeAs carbon ion radiotherapy increases in use, there are limited phantom materials for heterogeneous or anthropomorphic phantom measurements. This work characterized the radiological clinical equivalence of several phantom materials in a therapeutic carbon ion beam.MethodsEight materials were tested for radiological material‐equivalence in a carbon ion beam. The materials were computed tomography (CT)‐scanned to obtain Hounsfield unit (HU) values, then irradiated in a monoenergetic carbon ion beam to determine relative linear stopping power (RLSP). The corresponding HU and RLSP for each phantom material were compared to clinical carbon ion calibration curves. For absorbed dose comparison, ion chamber measurements were made in the center of a carbon ion spread‐out Bragg peak (SOBP) in water and in the phantom material, evaluating whether the material perturbed the absorbed dose measurement beyond what was predicted by the HU‐RLSP relationship.ResultsPolyethylene, solid water (Gammex and Sun Nuclear), Blue Water (Standard Imaging), and Techtron HPV had measured RLSP values that agreed within ±4.2% of RLSP values predicted by the clinical calibration curve. Measured RLSP for acrylic was 7.2% different from predicted. The agreement for balsa wood and cork varied between samples. Ion chamber measurements in the phantom materials were within 0.1% of ion chamber measurements in water for most materials (solid water, Blue Water, polyethylene, and acrylic), and within 1.9% for the rest of the materials (balsa wood, cork, and Techtron HPV).ConclusionsSeveral phantom materials (Blue Water, polyethylene, solid water [Gammex and Sun Nuclear], and Techtron HPV) are suitable for heterogeneous phantom measurements for carbon ion therapy. Low density materials should be carefully characterized due to inconsistencies between samples.
Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55
The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high level of achievable accuracy for a wide range of dose values and its suitability under a variety of measurement conditions. However, since the publication of the 1998 AAPM Task Group 55, Report No. 63 on RCF dosimetry, the chemistry, composition, and readout systems for RCFs have evolved steadily. There are several challenges in using the new RCFs, readout systems and validation of the results depending on their applications. Accurate RCF dosimetry requires understanding of RCF selection, handling and calibration methods, calibration curves, dose conversion methods, correction methodologies as well as selection, operation and quality assurance (QA) programs of the readout systems. Acquiring this level of knowledge is not straight forward, even for some experienced users. This Task Group report addresses these issues and provides a basic understanding of available RCF models, dosimetric characteristics and properties, advantages and limitations, configurations, and overall elemental compositions of the RCFs that have changed over the past 20 yr. In addition, this report provides specific guidelines for data processing and analysis schemes and correction methodologies for clinical applications in radiation therapy.