AAPM Task Group Report 336: Quality assurance for 3D printing in medical imaging and radiation therapy applications
Leng, Shuai, Craft, D. , Angel, Erin , Howell, Rebecca M., Jesseph, F., Kiarashi, Nooshin, Lewis, John H., Lo, Joseph, Markovic, Alex, McGee, Kiaran P. , Prah, D.E. , Rasmussen, Karl H., Rong, Yi, Schaefer, Kyle E., Solomon, Justin B., Leng, Shuai , Howell, Rebecca M. , Ionita, Ciprian N. , Lewis, John Henry , Lo, Joseph Yuan-Chieh , Solomon, Justin , Wake, Nicole

Medical Physics | April 29, 2026 | Volume: 53 | Issue: 5 | Pages: No page available

10.1002/mp.70446 Get It

Abstract Additive manufacturing (AM), commonly referred to as 3D printing, has been broadly used in the field of medical imaging and radiotherapy. In medical imaging applications, patient‐specific anatomic models have been used to aid in preoperative planning, patient communication, imaging technique assessment and optimization, and medical education. Within the field of radiation therapy, 3D printing finds significance in fabricating patient‐specific immobilization devices, custom bolus devices, anthropomorphic phantoms, brachytherapy devices, and electron therapy devices. Consistent with standard medical physics practices there is a need to establish quality assurance and quality control (QA/QC) protocols, tolerances, and testing frequencies. The diversity of 3D printing technologies and products poses challenges for medical adoption and thus requires guidelines in workflow standardization and establishment of testing procedures. This report is centered around providing comprehensive vendor‐neutral implementation guidelines and recommendations for QC and QA processes. The scope of this report encompasses diverse requirements within medical imaging and radiation therapy settings, serving both clinical and research purposes. Brief overview of 3D printing technology, common materials, and potential clinical applications is provided. QA team, infrastructure, measurement techniques and challenges are discussed. QA processes for each step in 3D printing are discussed in great detail and baseline and action limits are recommended. This report also touched on regulatory considerations. Key recommendations are summarized at the end of the report.
Characterization of LiF TLD‐100 in carbon ion beams for remote audits
Taylor, Paige A. , Mirandola, Alfredo , Ciocca, Mario , Hartzell, Shannon , Magro, Giuseppe , Alvarez, P , Peeler, C , Howell, Rebecca M. , Taylor, Paige , Peterson, Christine B. , Koay, Eugene J. , Kry, Stephen F.

Medical Physics | December 24, 2024 | Volume: 52 | Issue: 3 | Pages: 1858-1866

10.1002/mp.17605 Get It

Abstract Background A passive dosimeter framework for the measurement of dose in carbon ion beams has yet to be characterized or implemented for regular use. Purpose This work determined the dose calculation correction factors for absorbed dose in thermoluminescent dosimeters (TLDs) in a therapeutic carbon ion beam. TLD could be a useful tool for remote audits, particularly in the context of clinical trials as new protocols are developed for carbon ion radiotherapy. Methods TLD‐100 were irradiated in a carbon ion beam at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia, Italy. The dose correction factors for linearity, fading, and beam quality were characterized. Fading was characterized from 5 to 100 days post‐irradiation. For linearity, the TLDs were irradiated to absorbed doses ranging from 1 to 15 Gy in both the entrance of a high‐energy pristine carbon ion peak and the center of a 2 cm spread‐out Bragg peak. For beam quality, the TLD was irradiated to the same absorbed dose (3 Gy) in several pristine carbon ion Bragg peaks, as well as in several spread‐out Bragg peaks. Each correction factor was calculated and compared to photon correction factors. The correction factors were also compared between high and low dose‐averaged linear energy transfer (LET D ) in the carbon ion beams. The absorbed dose was compared between ion chamber and TLD‐100 in the several tissue substitute phantom materials, applying the carbon ion TLD correction factors. Results There was no statistically significant difference in the TLD fading correction factor between photons, low LET D carbon ion beams, or high LET D carbon ion beams. The TLD linearity correction factor did differ between photons, low LET D carbon ions, and high LET D carbon ions. The beam quality correction factor was large and changed linearly with LET D . The overall uncertainty of the carbon ion absorbed dose calculation was 3.9% at the one‐sigma level, driven largely by a 3.5% uncertainty in the beam quality correction. TLD measurements were within 1.2% of ion chamber measurements in the phantom material for polyethylene, solid water (Gammex and Sun Nuclear), acrylic, blue water, and techtron HPV. TLD measurements in balsa wood were within 3.0% and cork was 6.6% low compared to ion chamber. Conclusion TLD‐100 can be used for passive dosimetry in a therapeutic carbon ion beam. Importantly, the linearity and beam quality correction factors are both different from photon therapy, and dependent on LET D of the carbon ion beam. This opens the possibility of TLD use for carbon ion output audits, phantom audits, and in vivo dose measurements, but may be subject to more complicated management and slightly larger uncertainties than are achieved in photon beams.
OSLD nanoDot characterization for carbon radiotherapy dosimetry
Taylor, Paige A. , Hartzell, Shannon , Ciocca, Mario , Magro, Giuseppe , Alvarez, P , Peeler, C , Howell, Rebecca M. , Taylor, Paige , Mirandola, Alfredo , Peterson, Christine B. , Koay, Eugene J. , Kry, Stephen F.

Physics in Medicine & Biology | April 25, 2024 | Volume: 69 | Issue: 11 | Pages: 115001

10.1088/1361-6560/ad43ac Get It

Abstract Objective . This study characterized optically-stimulated luminescent dosimeter (OSLD) nanoDots for use in a therapeutic carbon beam using the Imaging and Radiation Oncology Core (IROC) framework for remote output verification. Approach . The absorbed dose correction factors for OSLD (fading, linearity, beam quality, angularity, and depletion), as defined by AAPM TG 191, were characterized for carbon beams. For the various correction factors, the effect of linear energy transfer (LET) was examined by characterizing in both a low and high LET setting. Main results . Fading was not statistically different between reference photons and carbon, nor between low and high LET beams; thus, the standard IROC-defined exponential function could be used to characterize fading. Dose linearity was characterized with a linear fit; while low and high LET carbon linearity was different, these differences were small and could be rolled into the uncertainty budget if using a single linearity correction. A linear fit between beam quality and dose-averaged LET was determined. The OSLD response at various angles of incidence was not statistically different, thus a correction factor need not be applied. There was a difference in depletion between low and high LET irradiations in a primary carbon beam, but this difference was small over the standard five readings. The largest uncertainty associated with the use of OSLDs in carbon was because of the k Q correction factor, with an uncertainty of 6.0%. The overall uncertainty budget was 6.3% for standard irradiation conditions. Significance . OSLD nanoDot response was characterized in a therapeutic carbon beam. The uncertainty was larger than for traditional photon applications. These findings enable the use of OSLDs for carbon absorbed dose measurements, but with less accuracy than conventional OSLD audit programs.
Technical note: Radiological clinical equivalence for phantom materials in carbon ion therapy
Taylor, Paige A. , Ciocca, Mario , Hartzell, Shannon , Vai, Alessandro , Alvarez, P , Howell, Rebecca M. , Peeler, C , Taylor, Paige , Mirandola, Alfredo , Koay, Eugene J. , Peterson, Christine B. , Kry, Stephen F.

Medical Physics | April 10, 2024 | Volume: 51 | Issue: 7 | Pages: 5154-5158

10.1002/mp.17056 Get It

AbstractPurposeAs carbon ion radiotherapy increases in use, there are limited phantom materials for heterogeneous or anthropomorphic phantom measurements. This work characterized the radiological clinical equivalence of several phantom materials in a therapeutic carbon ion beam.MethodsEight materials were tested for radiological material‐equivalence in a carbon ion beam. The materials were computed tomography (CT)‐scanned to obtain Hounsfield unit (HU) values, then irradiated in a monoenergetic carbon ion beam to determine relative linear stopping power (RLSP). The corresponding HU and RLSP for each phantom material were compared to clinical carbon ion calibration curves. For absorbed dose comparison, ion chamber measurements were made in the center of a carbon ion spread‐out Bragg peak (SOBP) in water and in the phantom material, evaluating whether the material perturbed the absorbed dose measurement beyond what was predicted by the HU‐RLSP relationship.ResultsPolyethylene, solid water (Gammex and Sun Nuclear), Blue Water (Standard Imaging), and Techtron HPV had measured RLSP values that agreed within ±4.2% of RLSP values predicted by the clinical calibration curve. Measured RLSP for acrylic was 7.2% different from predicted. The agreement for balsa wood and cork varied between samples. Ion chamber measurements in the phantom materials were within 0.1% of ion chamber measurements in water for most materials (solid water, Blue Water, polyethylene, and acrylic), and within 1.9% for the rest of the materials (balsa wood, cork, and Techtron HPV).ConclusionsSeveral phantom materials (Blue Water, polyethylene, solid water [Gammex and Sun Nuclear], and Techtron HPV) are suitable for heterogeneous phantom measurements for carbon ion therapy. Low density materials should be carefully characterized due to inconsistencies between samples.
Cardiac Substructure Radiation Dose and Risk of Late Cardiac Disease in Survivors of Childhood Cancer: A Report From the Childhood Cancer Survivor Study
Bates, James E. , Shrestha, Suman , Liu, Qi , Smith, Susan A. , Mulrooney, Daniel A. , Leisenring, Wendy M. , Robison, Leslie L. , Chow, Eric J. , Oeffinger, Kevin C. , Armstrong, Gregory T. , Howell, Rebecca M. , Leisenring, Wendy , Gibson, Todd , Robison, Leslie L , Chow, Eric J , Oeffinger, Kevin C , Constine, Louis S , Hoppe, Bradford S , Lee, Choonsik , Yasui, Yutaka , Mulrooney, Daniel A , Gibson, Todd M. , Hoppe, Bradford S.

Journal of Clinical Oncology | June 12, 2023 | Volume: 41 | Issue: 22 | Pages: 3826-3838

10.1200/jco.22.02320 Get It

PURPOSE Radiation-associated cardiac disease is a major cause of morbidity/mortality among childhood cancer survivors. Radiation dose-response relationships for cardiac substructures and cardiac diseases remain unestablished. METHODS Using the 25,481 5-year survivors of childhood cancer treated from 1970 to 1999 in the Childhood Cancer Survivor Study, we evaluated coronary artery disease (CAD), heart failure (HF), valvular disease (VD), and arrhythmia. We reconstructed radiation doses for each survivor to the coronary arteries, chambers, valves, and whole heart. Excess relative rate (ERR) models and piecewise exponential models evaluated dose-response relationships. RESULTS The cumulative incidence 35 years from diagnosis was 3.9% (95% CI, 3.4 to 4.3) for CAD, 3.8% (95% CI, 3.4 to 4.2) for HF, 1.2% (95% CI, 1.0 to 1.5) for VD, and 1.4% (95% CI, 1.1 to 1.6) for arrhythmia. A total of 12,288 survivors (48.2%) were exposed to radiotherapy. Quadratic ERR models improved fit compared with linear ERR models for the dose-response relationship between mean whole heart and CAD, HF, and arrhythmia, suggesting a potential threshold dose; however, such departure from linearity was not observed for most cardiac substructure end point dose-response relationships. Mean doses of 5-9.9 Gy to the whole heart did not increase the risk of any cardiac diseases. Mean doses of 5-9.9 Gy to the right coronary artery (rate ratio [RR], 2.6 [95% CI, 1.6 to 4.1]) and left ventricle (RR, 2.2 [95% CI, 1.3 to 3.7]) increased risk of CAD, and to the tricuspid valve (RR, 5.5 [95% CI, 2.0 to 15.1]) and right ventricle (RR, 8.4 [95% CI, 3.7 to 19.0]) increased risk of VD. CONCLUSION Among children with cancer, there may be no threshold dose below which radiation to the cardiac substructures does not increase the risk of cardiac diseases. This emphasizes their importance in modern treatment planning.
Low-dose radiation to cardiac substructures and late-onset cardiac disease: A report from the Childhood Cancer Survivor Study (CCSS).
Shrestha, Suman , Smith, Susan A. , Oeffinger, Kevin C. , Howell, Rebecca M. , Bates, James E. , Liu, Qi , Mulrooney, Daniel A. , Leisenring, Wendy M. , Gibson, Todd M. , Chow, Eric J. , Robison, Leslie L. , Armstrong, Gregory T. , Constine, Louis S , Hoppe, Bradford S. , Lee, Choonsik , Yasui, Yutaka

Journal of Clinical Oncology | June 2, 2021 | Volume: 39 | Issue: 15_suppl | Pages: 10027-10027

10.1200/jco.2021.39.15_suppl.10027 Get It

10027 Background: Thoracic radiotherapy (RT) is a risk factor for cardiac disease among survivors of childhood cancer based on studies considering RT doses to the entire heart. Dose to specific cardiac substructures may provide more precise dose-response associations to guide RT planning. We report associations between RT dose to cardiac substructures and risk of specific cardiac outcomes. Methods: We determined the cumulative incidences of CTCAE grade 3 – 5 coronary artery disease (CAD), heart failure (HF), and valvular disease (VD) among 25,481 5-year childhood cancer survivors diagnosed 1970 – 1999 in the CCSS. Median age at diagnosis was 6.1 years (0 – 20 years) and at last follow-up 29.8 years (5.6 – 65.9 years). For the 12,228 individuals receiving RT, fields were reconstructed on an age scaled computational phantom. Mean doses to the entire heart, cardiac chambers, valves, and left main, anterior descending (LAD), circumflex, and right coronary (RCA) arteries were estimated. Adjusted piecewise exponential models (including cumulative anthracycline dose) evaluated associations between mean RT dose to each structure and outcomes. Results: At 30 years from diagnosis, the cumulative incidences of grades 3 – 5 CAD, HF, and VD were 2.3% (95% CI 2.0 – 2.5), 2.6% (95% CI 2.4 – 2.9), and 0.6% (95% CI 0.5 – 0.8) respectively. Low dose RT (mean 5 – 9.9 Gy) to the RCA (relative rate [RR] = 2.6, 95% CI 1.6 – 4.1, p < 0.001), LAD (RR = 1.9, 95% CI 1.1 – 3.3, p = 0.019), and left ventricle (RR = 2.2, 95% CI 1.3 – 3.7, p = 0.002) was associated with increased risk of CAD relative to those not exposed; mean dose of 5 – 9.9 Gy to the entire heart was not (RR = 1.1, 95% CI = 0.8 – 1.6, p = 0.59). Table shows the associated cumulative incidences of CAD for these structures. Mean RT doses of 5 – 9.9 Gy to the aortic valve (RR = 4.6, 95% CI 1.5 – 14.0, p = 0.008) and tricuspid valve (RR = 5.5, 95% CI 2.0 – 15.1, p = 0.001) were associated with risk of VD compared to those with no RT; mean heart dose 5 – 9.9 Gy was not (RR = 0.6, 95% CI = 0.2 – 1.3, p = 0.16). No cardiac structure was significantly associated with an increased risk of HF at a mean dose of 5 – 9.9 Gy. Mean RT doses below 5 Gy were not associated with increased risks of CAD, HF, or VD; doses ≥10 Gy to nearly all substructures and the entire heart were. Conclusions: Low dose RT to the coronary arteries and cardiac valves (5 – 9.9 Gy) from RT is associated with increased risk of CAD and VD, respectively. Sensitivity to low dose RT may vary across the heart and doses to specific structures may be more predictive of late cardiac disease than whole heart dose. These data can guide RT planning to prioritize substructures for avoidance.[Table: see text]
Temporal trends among survivors of rhabdomyosarcoma: A report from the Childhood Cancer Survivor Study (CCSS).
Hingorani, Pooja , Wang, Mingjuan , Srivastava, Deo Kumar , Oeffinger, Kevin C. , Howell, Rebecca M. , Meyer, William H. , Arndt, Carola A.S., Nathan, Paul C. , Yasui, Yutaka , Leisenring, Wendy M. , Mueller, Emily L. , Gibson, Todd M. , Wolden, Suzanne L. , Bjornard, Kari L. , Robison, Leslie L. , Green, Daniel M. , Armstrong, Gregory T. , Ness, Kirsten K.

Journal of Clinical Oncology | March 6, 2020 | Volume: 37 | Issue: 15_suppl | Pages: 11570-11570

10.1200/jco.2019.37.15_suppl.11570 Get It

11570 Background: Intergroup Rhabdomyosarcoma Study Group (IRSG) protocols included treatment modifications, which may have ameliorated late health outcomes for rhabdomyosarcoma (RMS) survivors treated in more recent era. Methods: We evaluated chronic health conditions (CHCs) and late mortality ( > 5 years from diagnosis) among survivors treated 1970-1990 (IRSG I-III) and 1991-1999 (IRSG IV), and associations with specific treatments to identify treatment-related factors for adverse outcomes. Associations between treatments and CHCs and mortality were evaluated using Fine and Gray’s proportional hazards method accounting for competing risks. Results: 856 survivors treated 1970-90 (median diagnosis age 5.4 years [0- 20]) and 306 treated 1991-99 (median diagnosis age 5.5 years [0-20]) were included. Significant exposure differences between eras included higher percentage (53% vs. 17%, p < 0.01) receiving ≥ 20gm/m2 cumulative alkylators in 1991-99, but more receiving platinums (13% vs 5%, p < 0.01) and abdomen/ pelvis radiation (29% vs. 23%, p = 0.04) in 1970-90. 20-year cumulative incidence for any (40% vs. 28%, p < 0.01), ≥2 (16% vs. 7%, p < 0.01), and endocrine (8% vs. 2.5%, p < 0.01) grade 3-5 CHCs was higher in 1970-90 compared to 1991-99. The hazard ratio (HR) for any (HR 0.7, 95% Confidence Interval [CI] 0.55-0.9), ≥2 (HR 0.38, 95% CI 0.22-0.66) and endocrine (HR 0.25, 95% CI 0.09-0.67) grade 3-5 CHC was lower for 1991-99 survivors than 1970-90. The effect of era (1991-99 vs 1970-90, HR 0.73; 95% CI 0.59-0.91) on CHC was not attenuated when treatment variables were added to multivariable model. Exposures with increased risk of grade 3-5 CHC included platinums (hearing, HR 2, 95% CI 1.07-3.8), anthracycline ≥250mg/m2 (cardiovascular, HR 2.7, 95% CI 1.2-6) and abdomen/ pelvis radiation (second malignant neoplasms, HR 2.1, 95% CI 1.1-4, gastrointestinal, HR 7.4, 95% CI 3.5-16 and endocrine, HR 2.5, 95% CI 1.4-4.4). Gonadal dysfunction was the most common endocrine CHC. There was no difference in all cause or cause-specific mortality between the two cohorts. Conclusions: RMS survivors from the IRSG IV era are at reduced risk for late onset chronic health conditions compared to previous era.