Back to Authors

Solomon, Justin B.

Mayo Clinic

Duke University

Citations 2

AAPM Task Group Report 336: Quality assurance for 3D printing in medical imaging and radiation therapy applications
Leng, Shuai, Craft, D. , Angel, Erin , Howell, Rebecca M., Jesseph, F., Kiarashi, Nooshin, Lewis, John H., Lo, Joseph, Markovic, Alex, McGee, Kiaran P. , Prah, D.E. , Rasmussen, Karl H., Rong, Yi, Schaefer, Kyle E., Solomon, Justin B., Leng, Shuai , Howell, Rebecca M. , Ionita, Ciprian N. , Lewis, John Henry , Lo, Joseph Yuan-Chieh , Solomon, Justin , Wake, Nicole

Medical Physics | April 29, 2026 | Volume: 53 | Issue: 5 | Pages: No page available

10.1002/mp.70446 Get It

Abstract Additive manufacturing (AM), commonly referred to as 3D printing, has been broadly used in the field of medical imaging and radiotherapy. In medical imaging applications, patient‐specific anatomic models have been used to aid in preoperative planning, patient communication, imaging technique assessment and optimization, and medical education. Within the field of radiation therapy, 3D printing finds significance in fabricating patient‐specific immobilization devices, custom bolus devices, anthropomorphic phantoms, brachytherapy devices, and electron therapy devices. Consistent with standard medical physics practices there is a need to establish quality assurance and quality control (QA/QC) protocols, tolerances, and testing frequencies. The diversity of 3D printing technologies and products poses challenges for medical adoption and thus requires guidelines in workflow standardization and establishment of testing procedures. This report is centered around providing comprehensive vendor‐neutral implementation guidelines and recommendations for QC and QA processes. The scope of this report encompasses diverse requirements within medical imaging and radiation therapy settings, serving both clinical and research purposes. Brief overview of 3D printing technology, common materials, and potential clinical applications is provided. QA team, infrastructure, measurement techniques and challenges are discussed. QA processes for each step in 3D printing are discussed in great detail and baseline and action limits are recommended. This report also touched on regulatory considerations. Key recommendations are summarized at the end of the report.
Inter‐laboratory comparison of channelized hotelling observer computation
Ba, Alexandre, Abbey, Craig K. , Baek, Jongduk , Han, Minah , Balta, Christiana, Brankov, Jovan G. , Massanés, Francesc, Gifford, Howard C. , Veldkamp, Wouter J. H. , Petrov, Dimitar, Marshall, Nicholas , Samuelson, F. W. , Zeng, Rongping , Solomon, Justin B., Samei, Ehsan , Timberg, Pontus, Förnvik, Hannie, Reiser, Ingrid , Yu, Lifeng , Gong, Hao , Bochud, François , Bouwman, Ramona W. , Giron, Irene Hernandez , Solomon, Justin , Yu, Lifeng , Reiser, Ingrid

Medical Physics | April 28, 2018 | Volume: 45 | Issue: 7 | Pages: 3019-3030

10.1002/mp.12940 Get It

PurposeThe task‐based assessment of image quality using model observers is increasingly used for the assessment of different imaging modalities. However, the performance computation of model observers needs standardization as well as a well‐established trust in its implementation methodology and uncertainty estimation. The purpose of this work was to determine the degree of equivalence of the channelized Hotelling observer performance and uncertainty estimation using an intercomparison exercise.Materials and MethodsImage samples to estimate model observer performance for detection tasks were generated from two‐dimensional CT image slices of a uniform water phantom. A common set of images was sent to participating laboratories to perform and document the following tasks: (a) estimate the detectability index of a well‐defined CHO and its uncertainty in three conditions involving different sized targets all at the same dose, and (b) apply this CHO to an image set where ground truth was unknown to participants (lower image dose). In addition, and on an optional basis, we asked the participating laboratories to (c) estimate the performance of real human observers from a psychophysical experiment of their choice. Each of the 13 participating laboratories was confidentially assigned a participant number and image sets could be downloaded through a secure server. Results were distributed with each participant recognizable by its number and then each laboratory was able to modify their results with justification as model observer calculation are not yet a routine and potentially error prone.ResultsDetectability index increased with signal size for all participants and was very consistent for 6 mm sized target while showing higher variability for 8 and 10 mm sized target. There was one order of magnitude between the lowest and the largest uncertainty estimation.ConclusionsThis intercomparison helped define the state of the art of model observer performance computation and with thirteen participants, reflects openness and trust within the medical imaging community. The performance of a CHO with explicitly defined channels and a relatively large number of test images was consistently estimated by all participants. In contrast, the paper demonstrates that there is no agreement on estimating the variance of detectability in the training and testing setting.