Back to Authors

Ibbott, Geoffrey S.

0000-0003-3663-2408

Mayo Clinic

Associate Executive Director The American Board of Radiology Tucson Arizona USA

Citations 2

AAPM task group report 351: Protocol for clinical reference dosimetry in external beam MR‐guided radiotherapy
Sarfehnia, Arman , Alvarez, P , Bellon, M, Bouchard, Hugo , Dolan, James E., Malkov, Victor , Asselen, Bram van , Wolthaus, J., Prez, Leon de , Dolan, James E., Ibbott, Geoffrey S. , Muir, Bryan , Rogers, D. W. O. , Yadav, Poonam

Medical Physics | May 29, 2025 | Volume: 52 | Issue: 7 | Pages: No page available

10.1002/mp.17884 Get It

Abstract Background Magnetic Resonance‐guided Radiation Therapy (MRgRT) systems are increasingly used in clinical practice, necessitating a dedicated dosimetry protocol to address the challenges posed by the presence of strong magnetic fields. Purpose AAPM TG351 introduces a reference dosimetry protocol for external beam MRgRT systems, aligning with AAPM TG51 reports and incorporating elements from the IAEA TRS398 code of practice. Methods The protocol offers practical guidance on beam quality and dosimetry setup in the presence of strong magnetic fields. It reviews relevant literature to identify reference‐class chambers suitable for external beam MRgRT systems and determines their beam quality conversion and other relevant correction factors through a detailed analysis of available data and associated uncertainties. Results AAPM TG351 offers a comprehensive dosimetry protocol for external beam MRgRT systems, addressing the unique challenges posed by the presence of magnetic fields. It includes detailed guidance for measurement setups, a list of reference‐class chambers appropriate for reference dosimetry in MRgRT systems, and updated beam quality conversion and correction factors. Additionally, the protocol presents an in‐depth analysis of the uncertainty budget, identifying key contributors and providing strategies to minimize uncertainties, thereby enhancing clinical accuracy and reliability. Conclusions This protocol provides a practical, evidence‐based reference for medical physicists conducting reference dosimetry in external beam MRgRT systems.
AAPM task group report 314: Fault recovery in external beam radiation therapy
Sutlief, Steven , Buckey, C, Hadley, Scott, Curran, Bruce, Siochi, R , Tripathi, Sugata , Perrin, D, Young, Cheryl, Negrut, Cristina, Koehl, Susan, Shi, Jie, Ibbott, Geoffrey S. , Young, Cheryl, Robertson, Ian

Medical Physics | November 15, 2024 | Volume: 52 | Issue: 1 | Pages: 21-44

10.1002/mp.17502 Get It

Abstract Task Group (TG) 314 of the American Association of Physicists in Medicine (AAPM) was charged to develop guidance for recovering from fault states in radiation therapy, specifically regarding the delivery of photon or electron beams using a linear accelerator (linac) including ancillary systems. The fault conditions addressed may involve software, hardware, or a combination of causes. The report provides detailed recommendations for the proactive steps to be taken before a fault, the actions to be taken at the time of a fault, and the safety steps before returning a linac to clinical service, as well as the activities that device manufacturers and standard organizations can do to prevent and resolve the faults. A user‐maintained log of prior faults; establishment of remote access by the vendor; and user training in emergency gantry, couch, and door motions are all useful proactive steps. At the moment of downtime and after ensuring the safety of the patient, the report stresses the importance of capturing fault information, prompt contact with the service engineer after the initial assessment, and considerations for communicating the estimated duration before the linac is returned to service. The medical physicist has a critical responsibility to assess the impact of the fault on patient care. Before resuming clinical use, the medical physicist must both determine the level of testing required to ensure safe operation of the linac and ensure any partially or totally delivered treatments have been correctly saved for accurate completion of the treatment fraction. The report stresses the roles of the radiation therapist, medical physicist, and service engineer to efficiently and safely address linac downtime. The appendices contain a description of the efforts of several organizations regarding linac safety: Integrating the Healthcare Enterprise—Radiation Oncology, International Standards Organization/International Electrotechnical Commission, Radiation Oncology Safety Stakeholder Initiative, and the AAPM Vendor Relations and Product Usability Subcommittee. Disclaimer: The recommendations of this TG should not be used to establish regulations. These recommendations are guidelines for Qualified Medical Physicists and others to use and appropriately interpret for their institution and clinical setting. Each institution may have site‐specific or state‐mandated needs and requirements which may modify their usage of these recommendations.