Back to Authors

Soares, Christopher G.

Mayo Clinic

Dosimetry Consultant Duluth MN USA

Citations 2

Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55
Niroomand‐Rad, Azam, Chiu‐Tsao, Sou‐Tung, Lewis, David F. , Soares, Christopher G., Battum, L.J. van, Trichter, Samuel , Kissick, M, Alvarez, P , Grams, Michael P. , Das, Indra J. , Massillon-JL, G. , Chan, Maria F.

Medical Physics | September 29, 2020 | Volume: 47 | Issue: 12 | Pages: 5986-6025

10.1002/mp.14497 Get It

The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high level of achievable accuracy for a wide range of dose values and its suitability under a variety of measurement conditions. However, since the publication of the 1998 AAPM Task Group 55, Report No. 63 on RCF dosimetry, the chemistry, composition, and readout systems for RCFs have evolved steadily. There are several challenges in using the new RCFs, readout systems and validation of the results depending on their applications. Accurate RCF dosimetry requires understanding of RCF selection, handling and calibration methods, calibration curves, dose conversion methods, correction methodologies as well as selection, operation and quality assurance (QA) programs of the readout systems. Acquiring this level of knowledge is not straight forward, even for some experienced users. This Task Group report addresses these issues and provides a basic understanding of available RCF models, dosimetric characteristics and properties, advantages and limitations, configurations, and overall elemental compositions of the RCFs that have changed over the past 20 yr. In addition, this report provides specific guidelines for data processing and analysis schemes and correction methodologies for clinical applications in radiation therapy.
AAPM recommendations on medical physics practices for ocular plaque brachytherapy: Report of task group 221
Thomson, Rowan M. , Kaulich, Theodor W., Mourtada, Firas , Rivard, Mark J., Soares, Christopher G., Vanneste, Françoise M., Melhus, Christopher S. , Furutani, Keith M. , Vanneste, F.

Medical Physics | December 28, 2019 | Volume: 47 | Issue: 5 | Pages: No page available

10.1002/mp.13996 Get It

The American Association of Physicists in Medicine (AAPM) formed Task Group 221 (TG‐221) to discuss a generalized commissioning process, quality management considerations, and clinical physics practice standards for ocular plaque brachytherapy. The purpose of this report is also, in part, to aid the clinician to implement recommendations of the AAPM TG‐129 report, which placed emphasis on dosimetric considerations for ocular brachytherapy applicators used in the Collaborative Ocular Melanoma Study (COMS). This report is intended to assist medical physicists in establishing a new ocular brachytherapy program and, for existing programs, in reviewing and updating clinical practices. The report scope includes photon‐ and beta‐emitting sources and source:applicator combinations. Dosimetric studies for photon and beta sources are reviewed to summarize the salient issues and provide references for additional study. The components of an ocular plaque brachytherapy quality management program are discussed, including radiation safety considerations, source calibration methodology, applicator commissioning, imaging quality assurance tests for treatment planning, treatment planning strategies, and treatment planning system commissioning. Finally, specific guidelines for commissioning an ocular plaque brachytherapy program, clinical physics practice standards in ocular plaque brachytherapy, and other areas reflecting the need for specialized treatment planning systems, measurement phantoms, and detectors (among other topics) to support the clinical practice of ocular brachytherapy are presented. Expected future advances and developments for ocular brachytherapy are discussed.