Back to Authors

Asirvatham, Samuel J.

https://orcid.org/0000-0001-9835-5536

Mayo Clinic

Mayo Clinic

Citations 335

Trends in Use and Adverse Outcomes Associated with Transvenous Lead Removal in the United States
Deshmukh, Abhishek , Patel, Nileshkumar , Patel, Nileshkumar, Patel, Achint , Patel, Nilay, Patel, Nilay, Arora, Shilpkumar , Noheria, Amit , Mulpuru, Siva K. , Badheka, Apurva, Fischer, Avi, Coffey, James O., Cha, Yong‐Mei , Friedman, Paul A. , Asirvatham, Samuel J. , Viles-González, Juan F., Patel, Achint A, Kapa, Suraj , Mulpuru, Siva, Patel, Nileshkumar, Noseworthy, Peter A. , Patel, Nilay, Patel, Nilay, Asirvatham, Samuel J

Circulation | November 4, 2015 | Volume: 132 | Issue: 25 | Pages: 2363-2371

10.1161/circulationaha.114.013801 Get It

Background— Transvenous lead removal (TLR) has made significant progress with respect to innovation, efficacy, and safety. However, limited data exist regarding trends in use and adverse outcomes outside the centers of considerable experience for TLR. The aim of our study was to examine use patterns, frequency of adverse events, and influence of hospital volume on complications. Methods and Results— Using the Nationwide Inpatient Sample, we identified 91 890 TLR procedures. We investigated common complications including pericardial complications (hemopericardium, cardiac tamponade, or pericardiocentesis), pneumothorax, stroke, vascular complications (consisting of hemorrhage/hematoma, incidents requiring surgical repair, and accidental arterial puncture), and in-hospital deaths described with TLR, defining them by the validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis code. We specifically assessed in-hospital death (2.2%), hemorrhage requiring transfusion (2.6%), vascular complications (2.0%), pericardial complications (1.4%), open heart surgery (0.2%), and postoperative respiratory failure (2.4%). Independent predictors of complications were female sex and device infections. Hospital volume was not independently associated with higher complications. There was a significant rise in overall complication rates over the study period. Conclusions— The overall complication rate in patients undergoing TLR was higher than previously reported. Female sex and device infections are associated with higher complications. Hospital volume was not associated with higher complication rates. The number of adverse events in the literature likely underestimates the actual number of complications associated with TLR.
Lockstep
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | October 20, 2015 | Volume: 8 | Issue: 5 | Pages: 1289-1290

10.1161/circep.115.003224 Get It

Visualizing Risk for and Optimizing Prevention of Sudden Cardiac Death
Naksuk, Niyada , Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | September 2, 2015 | Volume: 26 | Issue: 11 | Pages: 1247-1249

10.1111/jce.12819 Get It

Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach?
Fu, Hai‐Xia , Huang, Xinmiao, Li, Zhong , Osborn, Michael J., Asirvatham, Samuel J. , Espinosa, Raúl E. , Brady, Peter A. , Lee, Hon-Chi , Greason, Kevin L. , Sohail, M. Rizwan , Acker, Nancy G., Hodge, David O. , Friedman, Paul A. , Cha, Yong‐Mei , Sohail, Rizwan M., Baddour, Larry M. , Asirvatham, Samuel J , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | August 21, 2015 | Volume: 38 | Issue: 12 | Pages: 1439-1447

10.1111/pace.12736 Get It

Wobble
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | August 18, 2015 | Volume: 8 | Issue: 4 | Pages: 985-987

10.1161/circep.115.002998 Get It

The Knot That Binds Mitral Valve Prolapse and Sudden Cardiac Death
Asirvatham, Samuel J. , Noseworthy, Peter A. , Asirvatham, Samuel J

Circulation | July 9, 2015 | Volume: 132 | Issue: 7 | Pages: 551-552

10.1161/circulationaha.115.017979 Get It

Editor’s Choice-Clinical impact of delirium and antipsychotic therapy: 10-Year experience from a referral coronary care unit
Naksuk, Niyada , Park, Jae Y, Sharma, Sunita, Gaba, Prakriti , Rosenbaum, Andrew , Peeraphatdit, Thoetchai , Hu, Tiffany , Bell, Malcolm R. , Herasevich, Vitaly , Brady, Peter A. , Asirvatham, Samuel J. , Rosenbaum, Andrew N , Hu, Tiffany Y, Kapa, Suraj , Thongprayoon, Charat , Asirvatham, Samuel J , Herasevich, Vitaly

European Heart Journal: Acute Cardiovascular Care | June 30, 2015 | Volume: 6 | Issue: 6 | Pages: 560-568

10.1177/2048872615592232 Get It

Atrioventricular Nodal Block With Atrioventricular Nodal Reentrant Tachycardia Ablation
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | June 16, 2015 | Volume: 8 | Issue: 3 | Pages: 745-747

10.1161/circep.115.002989 Get It

Direct Pulmonary Vein Ablation With Stenosis Prevention Therapy
Holmes, David R. , Ebrille, Elisa , Syed, Faisal F. , Ladewig, Dorothy J., Mikell, Susan B. , Powers, Joanne, Suddendorf, Scott H., Gilles, Emily J., Danielsen, Andrew J., Hodge, David O. , Asirvatham, Samuel J. , Kapa, Suraj , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | June 15, 2015 | Volume: 26 | Issue: 9 | Pages: 1000-1006

10.1111/jce.12732 Get It

Direct Pulmonary Vein Ablation With Stenosis Prevention TherapyIntroductionThe dominant location of electrical triggers for initiating atrial fibrillation (AF) originates from the muscle sleeves inside pulmonary veins (PVs). Currently, radiofrequency ablation (RFA) is performed outside of the PVs to isolate, rather than directly ablate these tissues, due to the risk of intraluminal PV stenosis.MethodsIn 4 chronic canine experiments, we performed direct PV muscle sleeve RFA ± postablation drug‐coated balloon (DCB) treatment with paclitaxel/everolimus. Of the 4 PVs, 2 PVs were ablated and treated with DCB, 1 PV was ablated without DCB treatment (positive control), and 1 PV was left as a negative control. Local electrograms were assessed in PVs for near‐field signals and were targeted for ablation. After 12–14 weeks survival, PVs were interrogated for absence of near‐field PV potentials, and each PV was assessed for stenosis.ResultsAll canines survived the study period without cardiorespiratory complications, and remained ambulatory. In all canines, PVs that were ablated and treated with DCB remained without any significant intraluminal stenosis. In contrast, PVs that were ablated and not treated with DCB showed near or complete intraluminal stenosis. At terminal study, PV potentials remained undetectable. A blinded, histologic analysis demonstrated that ablated PVs without DCB treatment had extensive thrombus, fibrin, mineralization, and elastin disruption.ConclusionOur chronic canine data suggest that direct PV tissue ablation without subsequent stenosis is feasible with the use of postablation DCBs.
Transcatheter tricuspid valve‐in‐valve in patients with transvalvular device leads
Eleid, Mackram F. , Asirvatham, Samuel J. , Hagler, Donald J. , Taggart, Nathaniel W. , Rihal, Charanjit S. , Cabalka, Allison K. , Noseworthy, Peter A. , Rihal, Charanjit S. , Asirvatham, Samuel J , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | May 6, 2015 | Volume: 87 | Issue: 4 | Pages: No page available

10.1002/ccd.25990 Get It

ObjectiveTo describe the effects of percutaneously implanted valve‐in‐valve in the tricuspid position for patients with pre‐existing transvalvular device leads.MethodsIn this case series, we describe implantation of the Melody valve and SAPIEN XT valve within dysfunctional bioprosthetic tricuspid valves in three patients with transvalvular device leads.ResultsIn all cases, the valve was successfully deployed and device lead function remained unchanged. In 1/3 cases with 6‐month follow‐up, device lead parameters remain unchanged and transcatheter valve‐in‐valve function remains satisfactory.ConclusionsTranscatheter tricuspid valve‐in‐valve is feasible in patients with pre‐existing transvalvular devices leads. Further study is required to determine the long‐term clinical implications of this treatment approach. © 2015 Wiley Periodicals, Inc.