Back to Authors

Cunningham, Scott A.

https://orcid.org/0000-0002-7589-1712

Mayo Clinic

Mayo Clinic

Citations 62

Desulfovibrio legallii Prosthetic Shoulder Joint Infection and Review of Antimicrobial Susceptibility and Clinical Characteristics of Desulfovibrio Infections
Vasoo, Shawn , Mason, Erin L., Gustafson, Daniel R., Cunningham, Scott A. , Cole, Nicolynn C., Vetter, Emily A., Steinmann, Scott P. , Wilson, Walter R., Patel, Robin , Berbari, Elie F. , Henry, Nancy K., Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | May 22, 2014 | Volume: 52 | Issue: 8 | Pages: 3105-3110

10.1128/jcm.00083-14 Get It

ABSTRACT We describe a case of shoulder hemiarthroplasty infection with Desulfovibrio legallii . Antimicrobial susceptibilities of 36 Desulfovibrio isolates are presented. Metronidazole and carbapenems exhibited reliable activity, although piperacillin-tazobactam did not. Eleven previous cases of Desulfovibrio infection are reviewed; most arose from a gastrointestinal tract-related source.
Inhibition Controls for Qualitative Real-Time PCR Assays: Are They Necessary for All Specimen Matrices?
Buckwalter, Seanne P., Sloan, Lynne M., Cunningham, Scott A. , Espy, Mark J., Uhl, J. R., Jones, Mary F. , Vetter, Emily A., Mandrekar, Jayawant N. , Cockerill, Franklin R., Pritt, Bobbi S. , Patel, Robin , Wengenack, Nancy L. , Patel, Robin , Pritt, Bobbi S , Cunningham, Scott A

Journal of Clinical Microbiology | April 16, 2014 | Volume: 52 | Issue: 6 | Pages: 2139-2143

10.1128/jcm.03389-13 Get It

ABSTRACT A retrospective analysis of 386,706 specimens representing a variety of matrix types used in qualitative real-time PCR assays determined the overall inhibition rate to be 0.87% when the inhibition control was added preextraction to 5,613 specimens and 0.01% when the inhibition control was added postextraction but preamplification in 381,093 specimens. Inhibition rates of ≤1% were found for all specimen matrix types except urine and formalin-fixed, paraffin-embedded tissue.
Streptococcus suis-Related Prosthetic Joint Infection and Streptococcal Toxic Shock-Like Syndrome in a Pig Farmer in the United States
Gomez, Eric, Kennedy, Cassie C. , Cunningham, Scott A. , Patel, Robin , Virk, Abinash, Gottschalk, Marcelo G , Virk, Abinash , Patel, Robin , Kennedy, Cassie C , Cunningham, Scott A

Journal of Clinical Microbiology | April 10, 2014 | Volume: 52 | Issue: 6 | Pages: 2254-2258

10.1128/jcm.02934-13 Get It

ABSTRACT Streptococcus suis is an emerging swine-associated zoonotic agent that can cause meningitis and septicemia in humans. We present, to our knowledge, the first case of S. suis arthroplasty infection and streptococcal toxic shock-like syndrome due to an nonencapsulated serotype 5 strain in North America.
Misidentification of Neisseria polysaccharea as Neisseria meningitidis with the Use of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
Cunningham, Scott A. , Mainella, Jill M., Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | April 3, 2014 | Volume: 52 | Issue: 6 | Pages: 2270-2271

10.1128/jcm.00664-14 Get It

Campylobacter Prosthetic Joint Infection
Vasoo, Shawn , Schwab, Jeramy J., Cunningham, Scott A. , Robinson, Trisha J., Cass, Joseph R., Berbari, Elie F. , Walker, Randall C., Osmon, Douglas R. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | February 13, 2014 | Volume: 52 | Issue: 5 | Pages: 1771-1774

10.1128/jcm.03572-13 Get It

ABSTRACTA 75-year-old man was diagnosed with probableCampylobacter jejuniprosthetic knee infection after a diarrheal illness. Joint aspirate and operative cultures were negative, but PCR of prosthesis sonicate fluid was positive, as was stool culture. Nineteen additional cases ofCampylobacterprosthetic joint infection reported in the literature are reviewed.
Rapid and Direct Real-Time Detection of bla KPC and bla NDM from Surveillance Samples
Vasoo, Shawn , Cunningham, Scott A. , Kohner, Peggy C., Mandrekar, Jayawant N. , Lolans, Karen , Hayden, Mary K. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | August 22, 2013 | Volume: 51 | Issue: 11 | Pages: 3609-3615

10.1128/jcm.01731-13 Get It

ABSTRACT We assessed the performance of a duplex real-time PCR assay for bla KPC and bla NDM performed directly (D-PCR) on perianal and perirectal swabs and stool. Spiked specimens and 126 clinical surveillance swabs (comprising a sensitivity panel of 46 perirectal double swabs previously determined to be culture positive for bla KPC -PCR-positive Enterobacteriaceae and a specificity panel of 80 perianal swabs from patients at risk of carbapenemase-producing Enterobacteriaceae [CPE] colonization) were studied. For the surveillance swabs, D-PCR was compared to PCR after broth enrichment (BE-PCR) and two culture-based methods: the HardyCHROM ESBL agar (HC-A) and the CDC screening (CDC-A) methods. PCR was performed on morphologically distinct colonies that were isolated by culture. All of the initial PCR testing was done without extraction using a simple lysis procedure. The analytical sensitivities of D-PCR for bla KPC were 9 CFU/μl (for swabs) and 90 CFU/μl (for stool), and for bla NDM , it was 1.9 CFU/μl (for both swabs and stool). In the clinical sensitivity panel, D-PCR and BE-PCR were initially positive for bla KPC in 41/46 (89.1%) and 43/46 (93.5%) swabs, respectively. The swabs that were initially negative by D-PCR ( n = 5) and BE-PCR ( n = 3) were visibly stool soiled; all swabs were bla KPC positive upon repeat testing after lysate extraction. The CDC-A and HC-A yielded bla KPC -positive Enterobacteriaceae from 36/46 (78.3%) and 35/46 (76.1%) swabs, respectively (sensitivities of D-PCR/BE-PCR postextraction of soiled specimens versus HC-A, P = 0.0009, and versus CDC-A, P = 0.0016). All swabs in the specificity panel were negative for CPE by all four methods. D-PCR allows for the timely detection of bla KPC and bla NDM carriage with excellent sensitivity when specimens visibly soiled with stool undergo preparatory extraction.
Comparison of a Novel, Rapid Chromogenic Biochemical Assay, the Carba NP Test, with the Modified Hodge Test for Detection of Carbapenemase-Producing Gram-Negative Bacilli
Vasoo, Shawn , Cunningham, Scott A. , Kohner, Peggy C., Simner, Patricia J. , Mandrekar, Jayawant N. , Lolans, Karen , Hayden, Mary K. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | July 4, 2013 | Volume: 51 | Issue: 9 | Pages: 3097-3101

10.1128/jcm.00965-13 Get It

ABSTRACT We compared carbapenemase detection among 271 Gram-negative bacilli (of which 131 were carbapenemase producers) using a novel chromogenic rapid test—the Carba NP test (CNP)—and the modified Hodge test (MHT). Sensitivities were comparable (CNP, 100%, versus MHT, 98%; P = 0.08), but CNP was more specific (100% versus 80%; P < 0.0001) and faster.
Rapid PCR Detection of Mycoplasma hominis, Ureaplasma urealyticum, and Ureaplasma parvum
Cunningham, Scott A. , Mandrekar, Jayawant N. , Rosenblatt, Jon E., Patel, Robin , Cunningham, Scott A

International Journal of Bacteriology | March 11, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-7

10.1155/2013/168742 Get It

Objective. We compared laboratory developed real-time PCR assays for detection of Mycoplasma hominis and for detection and differentiation of Ureaplasma urealyticum and parvum to culture using genitourinary specimens submitted for M. hominis and Ureaplasma culture. Methods. 283 genitourinary specimens received in the clinical bacteriology laboratory for M. hominis and Ureaplasma species culture were evaluated. Nucleic acids were extracted using the Total Nucleic Acid Kit on the MagNA Pure 2.0. 5 μL of the extracts were combined with 15 μL of each of the two master mixes. Assays were performed on the LightCycler 480 II system. Culture was performed using routine methods. Results. M. hominis PCR detected 38/42 M. hominis culture-positive specimens, as well as 2 that were culture negative (sensitivity, 90.5%; specificity, 99.2%). Ureaplasma PCR detected 139/144 Ureaplasma culture-positive specimens, as well as 9 that were culture negative (sensitivity, 96.5%; specificity, 93.6%). Of the specimens that tested positive for Ureaplasma species, U. urealyticum alone was detected in 33, U. parvum alone in 109, and both in 6. Conclusion. The described PCR assays are rapid alternatives to culture for detection of M. hominis and Ureaplasma species, and, unlike culture, the Ureaplasma assay easily distinguishes U. urealyticum from parvum.
Importance of Using Bruker's Security-Relevant Library for Biotyper Identification of Burkholderia pseudomallei, Brucella Species, and Francisella tularensis
Cunningham, Scott A. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | February 28, 2013 | Volume: 51 | Issue: 5 | Pages: 1639-1640

10.1128/jcm.00267-13 Get It

Rapid and Simultaneous Detection of Genes Encoding Klebsiella pneumoniae Carbapenemase ( bla KPC ) and New Delhi Metallo-β-Lactamase ( bla NDM ) in
Cunningham, Scott A. , Noorie, Tabassum, Woodford, Neil , Patel, Robin , Meunier, Danièle , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | January 24, 2013 | Volume: 51 | Issue: 4 | Pages: 1269-1271

10.1128/jcm.03062-12 Get It

ABSTRACT We present a duplex, real-time PCR assay for detection of Klebsiella pneumoniae carbapenemase ( bla KPC ) and New Delhi metallo-β-lactamase ( bla NDM ) genes. Accuracy was assessed with 158 Gram-negative bacillary isolates, including 134 carbapenemase producers. The assay had 100% sensitivity and specificity compared with reference methods and a turnaround time of 90 min.