ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA / vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml ( n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml ( n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.
Comparison of LightCycler PCR, Rapid Antigen Immunoassay, and Culture for Detection of Group A Streptococci from Throat Swabs
ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results ( n = 58) than either culture ( n = 55) or the Directigen immunoassay ( n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted “gold standard,” bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR ( n = 7) or the Directigen method ( n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant ( P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time (∼1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).
Direct Detection of
Legionella
Species from Bronchoalveolar Lavage and Open Lung Biopsy Specimens: Comparison of LightCycler PCR, In Situ Hybridization, Direct Fluorescence Antigen Detection, and Culture
ABSTRACT We developed a rapid thermocycling, real-time detection (also known as real-time PCR) method for the detection of Legionella species directly from clinical specimens. This method uses the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.) and requires approximately 1 to 2 h to perform. Both a Legionella genus PCR assay and Legionella pneumophila species-specific PCR assay were designed. A total of 43 archived specimens from 35 patients were evaluated, including 19 bronchoalveolar lavage (BAL) specimens and 24 formalin-fixed, paraffin-embedded open lung biopsy specimens. Twenty-five of the specimens were culture-positive for Legionella (9 BAL specimens and 16 tissue specimens). BAL specimens were tested by LightCycler PCR (LC-PCR) methods and by a direct fluorescent antibody (DFA) assay, which detects L. pneumophila serogroups 1 to 6 and several other Legionella species. Tissue sections were tested by the two LC-PCR methods, by DFA, by an in situ hybridization (ISH) assay, specifically designed to detect L. pneumophila , and by Warthin-Starry (WS) staining. The results were compared to the “gold standard” method of bacterial culture. With BAL specimens the following assays yielded the indicated sensitivities and specificities, respectively: Legionella genus detection by Legionella genus LC-PCR, 100 and 100%; Legionella genus detection by DFA assay, 33 and 100%; and L. pneumophila detection by L. pneumophila species-specific LC-PCR, 100 and 100%. With open lung biopsy specimens the following assays yielded the indicated sensitivities and specificities, respectively: Legionella genus detection by LC-PCR 68.8 and 100%; Legionella genus detection by DFA assay, 44 and 100%; Legionella genus detection by WS staining, 63 and 100%; L. pneumophila species-specific detection by LC-PCR, 17 and 100%; and L. pneumophila species-specific detection by ISH, 100 and 100%. The analytical sensitivity of both LC-PCR assays was <10 CFU/reaction. LC-PCR is a reliable method for the direct detection of Legionella species from BAL specimens. The Legionella genus LC-PCR assay could be performed initially; if positive, L. pneumophila species-specific LC-PCR could then be performed (if species differentiation is desired). The speed with which the LC-PCR procedure can be performed offers significant advantages over both culture-based methods and conventional PCR techniques. In contrast, for the methods evaluated, culture was the best for detecting multiple Legionella species in lung tissue. WS staining, Legionella genus LC-PCR, and L. pneumophila species-specific ISH were useful as rapid tests with lung tissue.