The decision to treat a patient with therapeutic apheresis depends on multiple factors, such as what does the patient most likely have, is the diagnosis amenable to apheresis treatment, what is the harm‐versus‐benefit ratio of apheresis treatment in this patient, and what are the internal and external issues associated with receiving apheresis treatment? The “ G uidelines on the U se of T herapeutic A pheresis in C linical P ractice— E vidence‐based A pproach from the Writing C ommittee of the A merican S ociety for A pheresis” addresses these issues and helps aid in clinical decision making. The development and application of these G uidelines as well as potential new applications will be discussed in this article.
SummaryThe initial description of therapeutic plasma exchange (TPE) in an animal model was published almost 100 years ago. Since that time, this treatment has been applied to a wide variety of diseases but limited research has been published examining the mechanisms of action ofTPE. The therapeutic effects ofTPEcould include the removal of pathological substances from the blood, such as monoclonal paraproteins and autoantibodies, as well as the replacement of deficient plasma components when plasma is used as a replacement fluid. Beyond these potential mechanisms, other possible mechanisms include possible alterations in lymphocyte proliferation and function that could sensitize these cells to immunosuppressant and chemotherapeutic agents and alterations in the immune system including changes inBandTcell numbers and activation, increasedTsuppressor function, and alteration inT‐helper cell type 1/2 (Th1/Th2) ratio. Much remains unknown about the mechanisms of action ofTPE, indicating a need for basic research into this therapy.
Thrombotic thrombocytopenic purpura: 2012 American Society for Apheresis (ASFA) consensus conference on classification, diagnosis, management, and future research
Guidelines on the Use of Therapeutic Apheresis in Clinical Practice—Evidence‐Based Approach from the Writing Committee of the American Society for Apheresis: The Sixth Special Issue
Discordant CD34+ cell results in peripheral blood and hematopoietic progenitor cell–apheresis product: implications for clinical decisions and impact on patient treatment
Case ReportA 50‐year‐old male with T‐cell lymphoma presented for autologous peripheral blood stem cell transplantation. After granulocyte–colony‐stimulating factor (G‐CSF) mobilization, his peripheral blood CD34+ cell count was 166 × 106/L on the day before collection, which predicted a high yield of CD34+ cells in the apheresis product. The first two collections had yields much lower than expected, triggering an investigation and changes to the apheresis collection methods since mobilization appeared adequate from the peripheral CD34+ values.ResultsChanges to the apheresis collection variables and instrumentation did not improve the yields in the next three collections. The laboratory investigation demonstrated that there was an interfering substance in the patient's plasma that was causing falsely high peripheral blood CD34+ cell values and that the low CD34+ cell yields in the collections were consistent with the actual peripheral blood CD34+ cell value. Based on this finding and after discussion with the clinical service, the patient then received plerixafor to increase the number of circulating CD34+ cells before Collections 6 and 7. The patient went on to achieve the target CD34+ cell dose and subsequently underwent a successful autologous transplant with full hematopoietic engraftment.ConclusionThis case demonstrates the importance of timely and critical review of laboratory results in the context of the specific patient. This case exemplifies how diligent review of laboratory results and open communication among the various teams can positively affect patient outcomes.
A multicenter evaluation of a new therapeutic plasma exchange procedure
BackgroundThe AMICUS (Fenwal, Inc.) was cleared in the United States for platelet (PLT) and plasma collection in 1996 with subsequent clearances for the collection of other blood products. Although not previously used for therapeutic plasma exchange (TPE), new disposables, software, and hardware were developed to enable TPE on the AMICUS.Study Design and MethodsA multicenter, randomized, nonblinded, crossover paired treatment protocol was performed. Thirty patients with orders for at least two TPE procedures were randomly assigned to the AMICUS or the COBE Spectra (TerumoBCT) for the first treatment. Each patient was crossed over to the other device using the same procedure settings from the first procedure. The primary objective compared efficiency of plasma removal (EPR) with secondary objectives of comparing PLT and hemoglobin (Hb) waste plasma content, coagulation factor and complement activation, fluid balance tracking accuracy, procedure length, and adverse events.ResultsThe EPR for the AMICUS (81.9 ± 7.62%) was superior to that of the COBE Spectra (75.2 ± 6.29%; p = 0.00001). The AMICUS also demonstrated statistically higher fluid balance accuracy (99.84%) compared to that of the COBE Spectra (98.83%; p < 0.0001) and a statistically shorter procedure time (103.9 ± 30.8 vs. 110.5 ± 27.1 min, p < 0.001). No significant differences with regard to PLT and Hb content in the waste plasma, change in patient PLT count, or changes in markers of coagulation and complement cascade activation were seen. Frequency and severity of adverse reactions were similar.ConclusionThe AMICUS separator can effectively perform TPE. The AMICUS demonstrated superior plasma removal efficiency compared to the COBE Spectra with no evidence of significant differences in PLT removal, hemolysis, and coagulation or complement activation.
Ticlopidine‐associated ADAMTS13 activity deficient thrombotic thrombocytopenic purpura in 22 persons in Japan: a report from the Southern Network on Adverse Reactions (SONAR)
BackgroundIdentifying antibodies to HLA (anti‐HLA) by solid‐phase assays is used to screen blood donors to mitigate transfusion‐related acute lung injury risk. Various cutoffs for detection assays have been proposed in the literature; however, these do not take into consideration lot‐to‐lot variability of commercially available assays.Study Design and MethodsSamples from 93 nontransfused males were tested using five different lots of a multiplex bead‐based anti‐HLA detection kit. A subset of 17 samples was tested on 5 days using a single lot. An additional 96 samples from donations with varied anti‐HLA levels were tested using kits from two different lots. Results were reported as a normalized background (NBG) ratio.ResultsFor the 93 nontransfused donors, NBG values generated using the reference lot were significantly higher than those obtained with three of the four comparator lots. However, for the 96 samples with low‐, moderate‐, and higher‐level anti‐HLA, Class I (CL‐I) values were 1.4 times lower and Class II (CL‐II) values were 1.2 times lower using the reference versus comparator lot. For CL‐I antibodies the between‐lot standard deviation (SD) was 1.36 (95% confidence interval [CI], 1.19‐1.60), while the between‐day SD was 1.27 (95% CI, 1.08‐1.52). Similarly, for CL‐II antibodies the between‐lot SD was 0.81 (95% CI, 0.70‐0.95), while the between‐day SD was 0.50 (95% CI, 0.43‐0.60).ConclusionsThere is interlot variability in the tested HLA detection assay as well as significant bias between lots. It may be reasonable to develop a new cutoff when a new lot is obtained.
Ticlopidine-, Clopidogrel-, and Prasugrel-Associated Thrombotic Thrombocytopenic Purpura: A 20-Year Review from the Southern Network on Adverse Reactions (SONAR)