Back to Authors

Shoffstall, Andrew J.

https://orcid.org/0000-0002-0881-2180

Mayo Clinic

Louis Stokes Cleveland VA Medical Center

Citations 4

Quantification of porcine lower thoracic spinal cord morphology with intact dura mater using high‐resolution μCT
Chin, J. , Settell, Megan L. , Brucker-Hahn, Meagan , Lust, Daniel, Zhang, Jichu , Upadhye, Aniruddha , Deshmukh, Ashlesha , Ludwig, Kip A. , Lavrov, Igor , Crofton, Andrew , Lempka, Scott F. , Chin, Justin , Brucker-Hahn, Meagan K , Upadhye, Aniruddha R , Deshmukh, Ashlesha , Ludwig, Kip A , Lavrov, Igor , Crofton, Andrew R , Lempka, Scott F , Zhang, Mingming , Shoffstall, Andrew J , Knudsen, Bruce E. , Shoffstall, Andrew J.

Journal of Neuroimaging | October 11, 2024 | Volume: 34 | Issue: 6 | Pages: 646-663

10.1111/jon.13239 Get It

AbstractBackground and PurposeSpinal cord stimulation (SCS) is approved by the Food and Drug Administration for treating chronic intractable pain in the back, trunk, or limbs through stimulation of the dorsal column. Numerous studies have used swine as an analog of the human spinal cord to better understand SCS and further improve its efficacy. We performed high‐resolution imaging of the porcine spinal cord with intact dura mater using micro‐computed tomography (μCT) to construct detailed 3‐dimensional (3D) visualizations of the spinal cord and characterize the morphology of the dorsal and ventral rootlets.MethodsWe obtained spinal cords from Yorkshire/Landrace crossbred swine (N = 7), stained samples with osmium tetroxide, and performed μCT imaging of the T12‐T15 levels at isotropic voxel resolutions ranging from 3.3 to 50 μm. We measured the anatomical morphology using the 3D volumes and compared our results to measurements previously collected from swine and human spinal cords via microdissection techniques in prior literature.ResultsWhile the porcine thoracic‐lumbar spinal cord is a popular model for SCS, we highlight multiple notable differences compared to previously published T8‐T12 human measurements including rootlet counts (porcine dorsal/ventral: 12.2 ± 2.6, 26.6 ± 3.4; human dorsal/ventral: 5.3 ± 1.3, 4.4 ± 2.4), rootlet angles (porcine ventral‐rostral: 161 ± 1°, ventral‐caudal: 155 ± 6°, dorsal‐rostral: 148 ± 9°, dorsal‐caudal: 142 ± 6°; human ventral‐rostral: 170 ± 3°, ventral‐caudal: 22 ± 10°, dorsal‐rostral: 171 ± 3°, dorsal‐caudal: 15 ± 7°), and the presence and count of dorsal rootlet bundles.ConclusionsDetailed measurements and highlighted differences between human and porcine spinal cords can inform variations in modeling and electrophysiological experiments between the two species. In contrast to other approaches for measuring the spinal cord and rootlet morphology, our method keeps the dura intact, reducing potential artifacts from dissection.
SPARC: A Road Map for Vagus Nerve Stimulation: Evidence of Vagotopy in a Swine Model
McConico, Andrea L., Nicolai, Evan N. , Ross, Erika K., Johnson, Aaron J. , Ludwig, Kip A. , Ludwig, Kip A , Settell, Megan L. , Knudsen, Bruce E. , Shoffstall, Andrew J. , Ross, Erika K., Pelot, Nicole A. , Grill, Warren M. , Johnson, Aaron J.

The FASEB Journal | April 19, 2020 | Volume: 34 | Issue: S1 | Pages: 1-1

10.1096/fasebj.2020.34.s1.07366 Get It

Cervical vagal nerve stimulation (VNS) is an FDA approved treatment for epilepsy and depression and is currently being evaluated for treatment of numerous other disorders including pain, anxiety, and inflammation. VNS also received European market approval for heart failure, bronchoconstriction, and diabetes; however, approval for these indications was based on studies in animals, such as dogs and rats, whose vagal nerve size may not have been representative of humans. When subjected to double‐blinded, randomized, sham controlled studies for subsequent U.S. approval, many of these CE‐marked VNS indications failed to meet their primary efficacy endpoints. More than 100,000 patients have undergone VNS, but despite the efficacy of vagal nerve stimulation in a subset of patients, many fail to reach stimulation levels that result in alleviation of symptoms without triggering unwanted side effects. Post hoc studies of the patient population suggested that VNS may not engage the intended fiber pathways in humans, despite engagement in preclinical studies in mouse, rat, or dog. Stimulation parameters were limited in these studies as higher parameters caused side effects such as cough, voice alteration, and dyspnea. Discrepancies between stimulation amplitude needed for intended effect versus unwanted side effect could be directly related to the relative size of the vagus nerve across animal models, variations in fascicle organization, or variations in branching patterns. To address translating improvements in VNS from the lab to the clinic, we evaluated the swine as a potential model for approximating the clinical environment. The size and fascicular organization of the swine vagus nerve is more representative of the human nerve than previously used models. We used a combination of histology, microdissection, and ultrasound to establish a distinct bimodal organization of groups of fascicles stemming from one large fascicle at the inferior (nodose) ganglion, an organization we have termed ‘vagotopy’. We demonstrated that with the use of ultrasound we can visualize the fascicular organization in vivo , an approach that could be used clinically to target stimulation of either sensory fibers or parasympathetic efferents, depending on therapeutic intent. These advances in a clinically relevant model not only inform electrode placement for target engagement, but provide an approach for reduction of side effects. Support or Funding Information Acknowledgements Funded by TL1TR002380 andThe Defense Advanced Research Projects Agency (DARPA) Biological Technologies Office (BTO) Targeted Neuroplasticity Training Program under the auspices of Doug Weber and Tristan McClure‐Begley through the Space and Naval Warfare Systems Command (SPAWAR) Systems Center with (SSC) Pacific grants no. N66001‐17‐2‐4010, and the NIH SPARC Program Award OT2 OD025340.
Neural Interfaces: An Injectable Neural Stimulation Electrode Made from an In‐Body Curing Polymer/Metal Composite (Adv. Healthcare Mater. 23/2019)
Baumgart, Ian W. , Nicolai, Evan N. , Gosink, Brian A., Asp, Anders J., Polaconda, Shyam , Malerick, Kevin D., Brodnick, Sarah K. , McConico, Andrea L., Sanger, Zachary , Lee, Jannifer H. , Aho, Johnathon M. , Ross, Erika K., Lujan, Jose L., Williams, Justin C. , Franke, Manfred , Trevathan, James K. , Asp, Anders J., Settell, Megan L. , Zeng, Weifeng , Knudsen, Bruce E. , Suminski, Aaron J. , Ross, Erika K., Weber, Douglas J. , Ludwig, Kip A. , Shoffstall, Andrew J.

Advanced Healthcare Materials | December 5, 2019 | Volume: 8 | Issue: 23 | Pages: No page available

10.1002/adhm.201970090 Get It

An Injectable Neural Stimulation Electrode Made from an In‐Body Curing Polymer/Metal Composite
Trevathan, James K. , Baumgart, Ian W. , Nicolai, Evan N. , Gosink, Brian A., Asp, Anders J., Settell, Megan L. , Polaconda, Shyam , Malerick, Kevin D., Brodnick, Sarah K. , Zeng, Weifeng , McConico, Andrea L., Sanger, Zachary , Lee, Jannifer H. , Aho, Johnathon M. , Ross, Erika K., Lujan, Jose L., Williams, Justin C. , Franke, Manfred , Ludwig, Kip A. , Shoffstall, Andrew J. , Knudsen, Bruce E. , Trevathan, James K , Ludwig, Kip A , Shoffstall, Andrew J , Asp, Anders J., Suminski, Aaron J. , Ross, Erika K., Weber, Douglas J.

Advanced Healthcare Materials | November 7, 2019 | Volume: 8 | Issue: 23 | Pages: No page available

10.1002/adhm.201900892 Get It

Abstract Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, a novel electrode that begins as an uncured, flowable prepolymer that can be injected around a neuroanatomical target to minimize surgical manipulation is developed. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, detailed electrochemical and microscopy characterization of its material properties is performed and the feasibility of using it to stimulate the nervous system electrically in rats and swine is validated. The silicone‐metal‐particle composite performs very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of its simplicity, the Injectrode has the potential to be less invasive, more robust, and more cost‐effective than traditional electrode designs, which could increase the adoption of neuromodulation therapies for existing and new indications.