Back to Authors

Nicolai, Evan N.

https://orcid.org/0000-0003-0447-568X

Mayo Clinic

Mayo Clinic

Citations 7

Abstract 361: Effects of Chronic, Intermittent Senescent Cell Clearance in Combination with Lipid Lowering on Inflammation in Perivascular Adipose Tissue
Nicolai, Evan N. , Hagler, Michael A , Roos, Carolyn M, Zhang, Bin , Miller, Jordan D.

Arteriosclerosis, Thrombosis, and Vascular Biology | April 7, 2025 | Volume: 39 | Issue: Suppl_1 | Pages: No page available

10.1161/atvb.39.suppl_1.361 Get It

Perivascular adipose tissue releases inflammatory paracrine factors that accelerate development of vascular dysfunction, atherosclerosis, and large vessel diseases such as abdominal aortic aneurysm. Our group has shown that chronic hypercholesterolemia and chronological aging both significantly increase senescent cell burden in vascular and endothelial cell populations of large arteries, but the effects of chronic hypercholesterolemia on senescent cell burden in perivascular adipose tissue—as well as the biological impact of reducing those senescent cells using pharmacological or genetic interventions—is poorly understood. Here, we sought to investigate the effects of chronic, intermittent senescent cell clearance by treating mice with Fisetin—a flavenoid shown to be a potent senolytic in multiple tissue types—and its potential synergies with risk factor mitigation. In brief, “Reversa” mice (ldlr-deficient, apoB100-only mice in which lipids can be lowered with a genetic switch) were fed a Western diet for 6 months, at which point they were randomized to one of three groups for 2 additional months: 1) continued progression on Western Diet (WD), 2) risk factor mitigation/lipid lowering with a genetic switch (LL) or 3) weekly, intermittent treatment with Fisetin + lipid lowering (FIS+LL). Compared to WD mice, LL mice had modest reductions in perivascular adipose inflammatory markers such as IL-6, CCL2, and CD-68, as well as the pro-oxidant Nox2; however, LL mice experienced no impact on expression of the pro-inflammatory cytokine TNFalpha. Interestingly, while intermittent Fisetin treatment and lipid lowering in the FIS+LL group had a significant additive effect on reducing IL-6, Nox2, and CD68, these changes were associated with modest reductions in expression of p16 ink4a or p21 (both of which are markers of senescent cell burden). Collectively, these data suggest that Fisetin is likely to modestly reduce senescent cell burden in perivascular fat, while effectively synergizing with lipid lowering to reduce a subset of inflammatory markers in this tissue, which may ultimately have implications for management of multiple age-associated vascular diseases.
Identification of intrinsic primary afferent neurons in mouse jejunum
Melo, Carina Guimarães de Souza , Nicolai, Evan N. , Alcaino, Constanza , Cassmann, Tiffany J., Whiteman, Sara, Wright, Alec M., Miller, Katie E., Gibbons, Simon J. , Beyder, Arthur , Linden, David R. , Whiteman, Sara T, Linden, D R , Beyder, Arthur , Gibbons, S J

Neurogastroenterology & Motility | September 28, 2020 | Volume: 32 | Issue: 12 | Pages: No page available

10.1111/nmo.13989 Get It

AbstractBackgroundThe gut is the only organ system with intrinsic neural reflexes. Intrinsic primary afferent neurons (IPANs) of the enteric nervous system initiate intrinsic reflexes, form gut‐brain connections, and undergo considerable neuroplasticity to cause digestive diseases. They remain inaccessible to study in mice in the absence of a selective marker. Advillin is used as a marker for primary afferent neurons in dorsal root ganglia. The aim of this study was to test the hypothesis that advillin is expressed in IPANs of the mouse jejunum.MethodsAdvillin expression was assessed with immunohistochemistry and using transgenic mice expressing an inducible Cre recombinase under the advillin promoter were used to drive tdTomato and the genetically encoded calcium indicator GCaMP5. These mice were used to characterize the morphology and physiology of advillin‐expressing enteric neurons using confocal microscopy, calcium imaging, and whole‐cell patch‐clamp electrophysiology.Key ResultsAdvillin is expressed in about 25% of myenteric neurons of the mouse jejunum, and these neurons demonstrate the requisite properties of IPANs. Functionally, they demonstrate calcium responses following mechanical stimuli of the mucosa and during antidromic action potentials. They have Dogiel type II morphology with neural processes that mostly remain within the myenteric plexus, but also project to the mucosa and express NeuN and calcitonin gene‐related peptide (CGRP), but not nNOS.Conclusions and InferencesAdvillin marks jejunal IPANs providing accessibility to this important neuronal population to study and model digestive disease.
SPARC: A Road Map for Vagus Nerve Stimulation: Evidence of Vagotopy in a Swine Model
McConico, Andrea L., Nicolai, Evan N. , Ross, Erika K., Johnson, Aaron J. , Ludwig, Kip A. , Ludwig, Kip A , Settell, Megan L. , Knudsen, Bruce E. , Shoffstall, Andrew J. , Ross, Erika K., Pelot, Nicole A. , Grill, Warren M. , Johnson, Aaron J.

The FASEB Journal | April 19, 2020 | Volume: 34 | Issue: S1 | Pages: 1-1

10.1096/fasebj.2020.34.s1.07366 Get It

Cervical vagal nerve stimulation (VNS) is an FDA approved treatment for epilepsy and depression and is currently being evaluated for treatment of numerous other disorders including pain, anxiety, and inflammation. VNS also received European market approval for heart failure, bronchoconstriction, and diabetes; however, approval for these indications was based on studies in animals, such as dogs and rats, whose vagal nerve size may not have been representative of humans. When subjected to double‐blinded, randomized, sham controlled studies for subsequent U.S. approval, many of these CE‐marked VNS indications failed to meet their primary efficacy endpoints. More than 100,000 patients have undergone VNS, but despite the efficacy of vagal nerve stimulation in a subset of patients, many fail to reach stimulation levels that result in alleviation of symptoms without triggering unwanted side effects. Post hoc studies of the patient population suggested that VNS may not engage the intended fiber pathways in humans, despite engagement in preclinical studies in mouse, rat, or dog. Stimulation parameters were limited in these studies as higher parameters caused side effects such as cough, voice alteration, and dyspnea. Discrepancies between stimulation amplitude needed for intended effect versus unwanted side effect could be directly related to the relative size of the vagus nerve across animal models, variations in fascicle organization, or variations in branching patterns. To address translating improvements in VNS from the lab to the clinic, we evaluated the swine as a potential model for approximating the clinical environment. The size and fascicular organization of the swine vagus nerve is more representative of the human nerve than previously used models. We used a combination of histology, microdissection, and ultrasound to establish a distinct bimodal organization of groups of fascicles stemming from one large fascicle at the inferior (nodose) ganglion, an organization we have termed ‘vagotopy’. We demonstrated that with the use of ultrasound we can visualize the fascicular organization in vivo , an approach that could be used clinically to target stimulation of either sensory fibers or parasympathetic efferents, depending on therapeutic intent. These advances in a clinically relevant model not only inform electrode placement for target engagement, but provide an approach for reduction of side effects. Support or Funding Information Acknowledgements Funded by TL1TR002380 andThe Defense Advanced Research Projects Agency (DARPA) Biological Technologies Office (BTO) Targeted Neuroplasticity Training Program under the auspices of Doug Weber and Tristan McClure‐Begley through the Space and Naval Warfare Systems Command (SPAWAR) Systems Center with (SSC) Pacific grants no. N66001‐17‐2‐4010, and the NIH SPARC Program Award OT2 OD025340.
SPARC: Neural elements mediating side effects during cervical vagus nerve stimulation in the pig
Nicolai, Evan N. , Williams, Justin C. , Ludwig, Kip A. , Ludwig, Kip A , Settell, Megan L. , Knudsen, Bruce E. , Pelot, Nicole A. , Grill, Warren M.

The FASEB Journal | April 19, 2020 | Volume: 34 | Issue: S1 | Pages: 1-1

10.1096/fasebj.2020.34.s1.07189 Get It

Vagus nerve stimulation (VNS) is FDA‐approved and CE‐marked for a diverse set of conditions including epilepsy, depression, heart failure, and others. Despite widespread adoption and perceived efficacy, a post‐hoc analysis of patients treated for heart failure using VNS revealed that only 12% of patients showed stimulation evoked heart rate changes one‐year post‐implant. This finding is not unexpected given that A‐type nerve fibers have the lowest activation thresholds, and they innervate neck muscles, causing contractions that patients will not tolerate. Therefore, muscle responses at lower amplitudes may have prevented application of higher amplitudes required to achieve cardiac effects in clinical trials of VNS for heart failure. Understanding therapy‐limiting side effects to VNS and finding ways to mitigate them are critical for optimizing VNS for clinical therapies. We developed a swine model of VNS which closely approximates the size and fascicular organization of the cervical vagus nerve observed in humans. The clinical LivaNova stimulation electrode was used as advised by a practicing neurosurgeon. We hypothesized that neck muscle responses are mediated by somatic branches of the vagus nerve as opposed to direct electrical activation of the muscle fibers. Further, we hypothesized that stimulation evoked responses depend on the location of the stimulation electrode on the vagus nerve. We measured compound nerve action potentials using intrafascicular electrodes placed within the vagus to identify activation of different nerve fiber types by conduction velocity. The downstream effects of nerve fiber activation, i.e. changes in heart rate and neck muscle responses (EMG), were measured using an arterial catheter and intramuscular electrodes, respectively. We then used a neuromuscular junction blocking agent, as well as systematic transection of somatic vagus nerve branches, to specifically identify the pathways causing neck muscle contractions. Two pathways contributed to VNS‐evoked neck muscle responses: activation of nerve fibers in the recurrent laryngeal branch of the cervical vagus nerve at low amplitudes and in the superior laryngeal branch at higher amplitudes. Lesser activation of the superior laryngeal branch could be achieved by moving the stimulation electrode caudally down the length of the vagus. This work represents a step towards mitigating intolerable side effects of VNS, thereby allowing maximization of intended target engagement and therapeutic benefit. Support or Funding Information The Defense Advanced Research Projects Agency (DARPA) Biological Technologies Office (BTO) Targeted Neuroplasticity Training Program under the auspices of Doug Weber and Tristan McClure‐Begley through the Space and Naval Warfare Systems Command (SPAWAR) Systems Center with (SSC) Pacific grants no. N66001‐17‐2‐4010, and the NIH SPARC Program Award OT2 OD025340.
Neural Interfaces: An Injectable Neural Stimulation Electrode Made from an In‐Body Curing Polymer/Metal Composite (Adv. Healthcare Mater. 23/2019)
Baumgart, Ian W. , Nicolai, Evan N. , Gosink, Brian A., Asp, Anders J., Polaconda, Shyam , Malerick, Kevin D., Brodnick, Sarah K. , McConico, Andrea L., Sanger, Zachary , Lee, Jannifer H. , Aho, Johnathon M. , Ross, Erika K., Lujan, Jose L., Williams, Justin C. , Franke, Manfred , Trevathan, James K. , Asp, Anders J., Settell, Megan L. , Zeng, Weifeng , Knudsen, Bruce E. , Suminski, Aaron J. , Ross, Erika K., Weber, Douglas J. , Ludwig, Kip A. , Shoffstall, Andrew J.

Advanced Healthcare Materials | December 5, 2019 | Volume: 8 | Issue: 23 | Pages: No page available

10.1002/adhm.201970090 Get It

An Injectable Neural Stimulation Electrode Made from an In‐Body Curing Polymer/Metal Composite
Trevathan, James K. , Baumgart, Ian W. , Nicolai, Evan N. , Gosink, Brian A., Asp, Anders J., Settell, Megan L. , Polaconda, Shyam , Malerick, Kevin D., Brodnick, Sarah K. , Zeng, Weifeng , McConico, Andrea L., Sanger, Zachary , Lee, Jannifer H. , Aho, Johnathon M. , Ross, Erika K., Lujan, Jose L., Williams, Justin C. , Franke, Manfred , Ludwig, Kip A. , Shoffstall, Andrew J. , Knudsen, Bruce E. , Trevathan, James K , Ludwig, Kip A , Shoffstall, Andrew J , Asp, Anders J., Suminski, Aaron J. , Ross, Erika K., Weber, Douglas J.

Advanced Healthcare Materials | November 7, 2019 | Volume: 8 | Issue: 23 | Pages: No page available

10.1002/adhm.201900892 Get It

Abstract Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, a novel electrode that begins as an uncured, flowable prepolymer that can be injected around a neuroanatomical target to minimize surgical manipulation is developed. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, detailed electrochemical and microscopy characterization of its material properties is performed and the feasibility of using it to stimulate the nervous system electrically in rats and swine is validated. The silicone‐metal‐particle composite performs very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of its simplicity, the Injectrode has the potential to be less invasive, more robust, and more cost‐effective than traditional electrode designs, which could increase the adoption of neuromodulation therapies for existing and new indications.
Design Choices for Next-Generation Neurotechnology Can Impact Motion Artifact in Electrophysiological and Fast-Scan Cyclic Voltammetry Measurements
Nicolai, Evan N. , Michelson, Nicholas J. , Settell, Megan L. , Hara, Seth A. , Trevathan, James K. , Asp, Anders J., Stocking, Kaylene C., Luján, J. Luis , Kozai, Takashi D.Y. , Ludwig, Kip A. , Trevathan, James K , Ludwig, Kip A , Asp, Anders J.

Micromachines | September 28, 2018 | Volume: 9 | Issue: 10 | Pages: 494

10.3390/mi9100494 Get It

Implantable devices to measure neurochemical or electrical activity from the brain are mainstays of neuroscience research and have become increasingly utilized as enabling components of clinical therapies. In order to increase the number of recording channels on these devices while minimizing the immune response, flexible electrodes under 10 µm in diameter have been proposed as ideal next-generation neural interfaces. However, the representation of motion artifact during neurochemical or electrophysiological recordings using ultra-small, flexible electrodes remains unexplored. In this short communication, we characterize motion artifact generated by the movement of 7 µm diameter carbon fiber electrodes during electrophysiological recordings and fast-scan cyclic voltammetry (FSCV) measurements of electroactive neurochemicals. Through in vitro and in vivo experiments, we demonstrate that artifact induced by motion can be problematic to distinguish from the characteristic signals associated with recorded action potentials or neurochemical measurements. These results underscore that new electrode materials and recording paradigms can alter the representation of common sources of artifact in vivo and therefore must be carefully characterized.