Back to Authors

Taggart, Nathaniel W.

https://orcid.org/0000-0002-7424-8207

Mayo Clinic

Mayo Clinic

Citations 41

Temporary balloon occlusion of atrial septal defects in suspected or documented left ventricular diastolic dysfunction: Hemodynamic and clinical findings
Miranda, William R. , Hagler, Donald J. , Reeder, Guy S., Warnes, Carole A. , Connolly, Heidi M. , Egbe, Alexander C. , Taggart, Nathaniel W. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | February 12, 2019 | Volume: 93 | Issue: 6 | Pages: 1069-1075

10.1002/ccd.28150 Get It

AbstractObjectiveTo review our experience with balloon testing prior to atrial septal defect (ASD) closure in adults with left ventricular (LV) diastolic dysfunction.BackgroundASD closure in patients with LV diastolic dysfunction may precipitate LV failure. Temporary ASD occlusion has been used in this scenario but data are limited.MethodsRetrospective review of 27 patients age ≥ 50 years undergoing temporary ASD balloon occlusion between 2000 and 2018 for suspected LV diastolic dysfunction or elevated LV end‐diastolic pressure (LVEDP).ResultsMedian age was 72 years (IQR 66.7; 75.2). Atrial fibrillation was seen in 58% of patients, hypertension in 58%, and coronary artery disease in 26%; 52% were females. Median ASD size was 13 mm (10; 18) and Qp/Qs 1.8 (1.6; 2.2). Median LVEDP was 14 mmHg (12; 22); pulmonary artery wedge pressure (PAWP) 12 mmHg (9; 16.5) and left atrial pressure (LAP) 13.5 mmHg (8; 16.3). After a median of 5 min (3; 10) of balloon occlusion, patients with baseline LVEDP ≥15 mmHg had more significant increases in LVEDP (9 [6; 12] vs. 2 mmHg [0.5; 5]; p = 0.03) and LAP/PAWP (10.5 [8.3; 16.3] vs. 1.5 mmHg [−1.5; 3]; p = 0.0003) than those with baseline LVEDP <15 mmHg. None of those with a baseline LVEDP <15 mmHg had a LAP/PAWP >15 mmHg during balloon testing compared to 92% of patients with a baseline LVEDP ≥15 mmHg.ConclusionLVEDP might be used to predict LAP post‐ASD closure. Comorbidities typically associated with LV diastolic dysfunction are common in these patients and should be considered in their management.
Ultrasound guided percutaneous common carotid artery access in piglets for intracoronary stem cell infusion
Taggart, Nathaniel W. , Edgerton, Sarah, Peral, Susana Cantero, Holst, Kimberly , Cetta, Frank , Anderson, Jason H. , Edgerton, Sarah L, Cantero Peral, Susana, Holst, Kimberly A, Taggart, Nathaniel W

Laboratory Animals | July 20, 2017 | Volume: 52 | Issue: 1 | Pages: 88-92

10.1177/0023677217719923 Get It

In pigs, the deep location of the common carotid artery and overlying sternomastoideus muscle in the neck has led to the recommendation for a surgical cutdown for common carotid access, as opposed to minimally invasive techniques for vascular access. We sought to determine if direct percutaneous common carotid artery access in piglets is attainable. Seventeen piglets were anesthetized and intubated. Under two-dimensional and color flow Doppler ultrasound guidance, a 21 gauge needle was utilized to access the right common carotid artery. Following arterial puncture, the Seldinger technique was applied to place a 4 or 5 French introducer. Upon completion of cardiac catheterization with intracoronary stem cell infusion the introducer was removed and manual pressure was applied to prevent hematoma development. Successful access with an introducer was achieved in all 17 piglets. The average weight was 8.5 ± 1.7 kg. One piglet developed a hematoma with hemorrhaging from the catheterization site and was euthanized. This piglet was given bivalirudin for the procedure. After this incident, subsequent piglets were not given anticoagulation and no other complications occurred. Ultrasound guided percutaneous common carotid artery access in piglets is attainable in a safe, reliable, and reproducible manner when performed by microvascular experts.
Acute and midterm results following perventricular device closure of muscular ventricular septal defects: A multicenter PICES investigation
Gray, Robert G. , Menon, Shaji C. , Johnson, Joyce T. , Bingler, Michael, Breinholt, John P. , Kenny, Damien , Lozier, John S. , Murphy, Joshua, Sathanandam, Shyam , Taggart, Nathaniel W. , Trucco, Sara M. , Goldstein, Bryan H. , Gordon, Brent M. , Armstrong, Aimee K. , Taggart, Nathaniel W , Goldstein, Bryan H

Catheterization and Cardiovascular Interventions | May 8, 2017 | Volume: 90 | Issue: 2 | Pages: 281-289

10.1002/ccd.27121 Get It

ObjectivesTo describe acute and mid‐term results of hybrid perventricular device closure of muscular ventricular septal defects (mVSDs).BackgroundPerventricular device closure of mVSDs can mitigate technical limitations of percutaneous closure and need for cardiopulmonary bypass or ventriculotomy with a surgical approach.MethodsThis is a multicenter retrospective cohort study of patients undergoing hybrid perventricular mVSD device closure from 1/2004 to 1/2014. Procedural details, adverse events, outcomes, and follow‐up data were collected. Patients were divided into two groups: (1) simple (mVSD closure alone) and (2) complex (mVSD closure with concomitant cardiac surgery).ResultsForty‐seven patients (60% female) underwent perventricular mVSD device closure at a median age of 5.2 months (IQR 1.8–8.9) and weight of 5.1 kg (IQR 4.0–6.9). Procedural success was 91% [100% (n = 22) simple and 84% (n = 21/25) complex]. Adverse events occurred in 19% (9/47) [9% (2/22) simple and 28% (7/25) complex]. Hospital length of stay (LOS) was shorter in the simple vs. complex group (4 vs. 14 days, P < 0.01). At mid‐term follow‐up of 19.2 months (IQR 2.3–43) 90% of pts had complete mVSD closure; none developed late heart block, increased atrioventricular (AV) valve insufficiency or ventricular dysfunction.ConclusionsPerventricular device closure of simple mVSD was associated with a high rate of procedural success, few adverse events, and short hospital LOS. Procedural adverse events were associated with the presence of concomitant complex surgery. Residual mVSD, AV valve insufficiency, or ventricular dysfunction were uncommon at mid‐term follow‐up. © 2017 Wiley Periodicals, Inc.
Novel delivery technique for atrial septal defect closure in young children utilizing the GORE® CARDIOFORM® septal occluder
Anderson, Jason H. , Fraint, Hannah, Moore, Phillip , Taggart, Nathaniel W. , Cabalka, Allison K. , Taggart, Nathaniel W , Anderson, Jason

Catheterization and Cardiovascular Interventions | November 29, 2016 | Volume: 89 | Issue: 7 | Pages: 1232-1238

10.1002/ccd.26874 Get It

ObjectivesTo develop a novel delivery technique to overcome vascular size limitations for device closure of a secundum ASD in the young patient.BackgroundThe efficacy, clinical utility, and safety of transcatheter closure in comparison to surgical closure are well established; however, access vessel size remains a potential limitation to device selection in the young patient.MethodsA retrospective medical record review of all cases of secundum ASD closure between April 2015 and April 2016 utilizing a novel delivery method described herein at two separate academic institutions. The device is disassembled allowing the delivery sheath to serve as the introducer. It is advanced to the RA with re‐introduction of the device allowing for deployment in the standard fashion.ResultsOverall, 10 patients underwent secundum ASD closure via this novel delivery technique. There were six females (60%) and the average age at time of the procedure was 4.2 years ± 1.6 years (range 2–6 years). The majority of patients had an isolated secundum ASD (70%) with the primary indication for closure being right ventricular volume overload (90%). All patients had successful placement of a GORE® CARDIOFORM® Septal Occluder (GCSO) with no or trivial residual shunt. No patients had vascular complications related to the procedure.ConclusionsWe describe a novel technique for ASD closure using the GCSO delivery sheath as the access sheath, which reduces the vascular access size requirement by 25%, thus addressing one common limitation for percutaneous device closure of a secundum ASD in young patients. © 2016 Wiley Periodicals, Inc.
Intravascular and hybrid intraoperative stent placement for baffle obstruction in transposition of the great arteries after atrial switch
Poterucha, Joseph T., Taggart, Nathaniel W. , Johnson, Jonathan N. , Cannon, Bryan C. , Hagler, Donald J. , Cetta, Frank , Cabalka, Allison K. , Dearani, Joseph A. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | October 27, 2016 | Volume: 89 | Issue: 2 | Pages: 306-314

10.1002/ccd.26783 Get It

ObjectivesTo report our experience with intravascular and hybrid intra‐operative stent placement for baffle obstruction in patients with complete transposition of the great arteries (TGA) after the atrial switch (Mustard/Senning) operation.BackgroundVenous baffle obstruction is a challenging complication after atrial switch operation in patients with TGA. Traditional treatment options include intravascular stenting or surgery.MethodsA retrospective analysis of Mayo Clinic's electronic medical record was completed to identify consecutive pediatric and adult patients with TGA after atrial switch who underwent baffle stent implantation from 1994 to 2015.ResultsOverall, 64 patients were referred for cardiac catheterization, in whom 47 (73%) were noted to have hemodynamic and angiographic evidence of baffle obstruction. A total of 20 patients mean age 33 (range: 8–46) years old underwent stent implantation of baffle stenosis at a mean of 33 (range: 7.5–45) years after initial atrial switch operation (Mustard, n = 19; Senning, n = 1). Overall, 27 baffles were stented in 20 patients via the following approaches: intravascular (17); hybrid surgical (3); staged intravascular & hybrid (2). Sites of stent placement were: superior vena cava (SVC) (13); inferior vena cava (IVC) (9); pulmonary venous baffle (5). Three patients had stent placement in the SVC and IVC baffles during the same procedure. Procedural adverse events occurred in 2/22 cases (9%) including creation of unintentional baffle leak (n = 1) and stent migration (n = 1). There was no procedure‐related mortality. At follow‐up (median 2, range 0.02–10 years), significantly improved NYHA class and mean Doppler baffle gradient were demonstrated (P < 0.05). Mild baffle re‐stenosis (mean Doppler gradient; 2–3 mmHg) occurred in two patients who have not required re‐intervention. Trivial baffle leak was noted in four patients. Baffle re‐intervention was only occurred in one patient. One patient with pre‐procedural Class IV symptoms died 3.5 months after stent implantation.ConclusionsThis study is the largest reported experience of intravascular and intra‐operative hybrid stent placement for patients with TGA after atrial switch. Transcatheter and minimally invasive hybrid intraoperative surgical stent placement are an effective strategy for relief of systemic and pulmonary venous baffle obstruction. © 2016 Wiley Periodicals, Inc.
AngioJet™ thrombolysis of SVC thrombosis after orthotopic heart transplantation: A case report
Sessions, Kristen L., Anderson, Jason H. , Johnson, Jonathan N. , Taggart, Nathaniel W. , Taggart, Nathaniel W , Anderson, Jason

Pediatric Transplantation | April 19, 2016 | Volume: 20 | Issue: 5 | Pages: 723-726

10.1111/petr.12715 Get It

AbstractSVC obstruction is a rare acute complication after bicaval cardiac transplantation and can be catastrophic for the patient. Herein, we report the case of a child who developed SVC thrombosis causing acute SVC syndrome nine days after heart transplantation. Thrombolysis was successfully performed using the AngioJet™ system and subsequent balloon angioplasty with re‐establishment of flow. This procedure allowed for revascularization without repeat sternotomy or stent implantation. The patient is well without recurrence at last follow‐up.
Long‐term follow‐up after PFO device closure
Taggart, Nathaniel W. , Reeder, Guy S., Lennon, Ryan J. , Slusser, Joshua P. , Freund, Monique , Cetta, Frank , Hagler, Donald J. , Freund, Monique A, Cabalka, Allison K. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | March 31, 2016 | Volume: 89 | Issue: 1 | Pages: 124-133

10.1002/ccd.26518 Get It

ObjectivesTo describe medium‐ to long‐term follow‐up of patients undergoing device closure of patent foramen ovale (PFO) for stroke or transient ischemic attack (TIA).BackgroundTranscatheter device closure of PFO continues to be used for secondary prevention of cryptogenic stroke or TIA, but data are lacking regarding long‐term outcomes.MethodsWe reviewed the Mayo Clinic Rochester PFO database for patients who underwent device closure of PFO for secondary prevention of stroke/TIA from December 2001 to June 2012. Demographic, clinical, procedural, and follow‐up data were reviewed. Recurrence rate of stroke/TIA were calculated. Data were analyzed to identify risk factors of recurrent neurologic events.ResultsSeven hundred and thirty patients (mean age 53 years; 40% female) were included in our study. Most patients (72%) had cryptogenic stroke as their qualifying event for PFO closure. There were no procedure‐related deaths or strokes. The most commonly used device was the Amplatzer Septal Occluder (82%). Median follow‐up was 6 years. A 3.9% of patients had documented residual right‐to‐left shunting at last echocardiogram. Recurrent stroke and/or TIA were reported in 45 patients, (6.3% of patients with follow‐up data). Patients who experienced recurrent stroke/TIA were older and had a higher rate of diabetes and hypertension than those who did not. The presence of residual shunt did not correlate with risk of recurrent events.ConclusionsDevice closure of PFO can be performed safely with very good long‐term resolution of atrial shunting. Recurrent neurologic events after PFO closure may reflect additional comorbid risk factors unrelated to the potential for paradoxical embolism. © 2016 Wiley Periodicals, Inc.
Three-Dimensional Rotational Angiography-Guided Stent Placement for Treatment of Acquired Supravalvar Aortic Stenosis
Anderson, Jason H. , Fetterly, Kenneth A. , Taggart, Nathaniel W. , Taggart, Nathaniel W , Anderson, Jason

Circulation | August 3, 2015 | Volume: 132 | Issue: 5 | Pages: 455-456

10.1161/circulationaha.115.017612 Get It

Transcatheter closure of postmyocardial infarction, iatrogenic, and postoperative ventricular septal defects: The Mayo Clinic experience
Egbe, Alexander C. , Poterucha, Joseph T., Rihal, Charanjit S. , Taggart, Nathaniel W. , Cetta, Frank , Pollak, Peter , Reeder, Guy S., Hagler, Donald J. , Cabalka, Allison K. , Pollak, Peter M, Rihal, Charanjit S. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | May 29, 2015 | Volume: 86 | Issue: 7 | Pages: 1264-1270

10.1002/ccd.25989 Get It

Objectives To determine event‐free survival after transcatheter closure of ventricular septal defect (VSD), and to identify predictors of adverse events (AE) in post myocardial infarction VSD (post‐MI VSD) subgroup. Background There are limited data on mid‐term follow‐up after transcatheter VSD closure. Methods Retrospective review of 27 cases of transcatheter VSD closure (post‐MI = 18 and non‐ischemic = 9) performed from 1999 to 2013. We defined AE as death, device embolization, hemolysis requiring blood transfusion, heart block and reintervention. Results In the post‐MI VSD subgroup, mean age and follow‐up was 69 ± 11 and 7.3 ± 7 years, respectively. AE occurred in 8 (44%) patients (death‐3, device embolization‐1, hemolysis‐1, surgical VSD closure‐2, reintervention‐1). Event‐free survival was 56% at 1 month and 5 years, and all AE occurred in the periprocedural period. Cardiogenic shock (HR: 3.21, CI: 1.82–5.41, P = 0.002), and VSD closure in acute phase (HR: 2.14, CI: 1.12–4.31, P = 0.004) were independent predictors of AE. In the non‐ischemic VSD subgroup, mean age and follow‐up was 49 ± 15 and 8.7 ± 8 years, respectively. AE occurred in 3 (33%) patients (late death‐1, surgical VSD closure‐2). For the entire cohort, freedom from death was 89% and 85% at 1 month and 5 years, and event‐free survival was 70% and 61% at 1 month and 5 years. Conclusions Transcatheter closure of post‐MI VSD carries a moderate risk of periprocedural complications but low event rates afterwards. By comparison, device closure of non‐ischemic VSD has lower periprocedural morbidity but some patients continued to experience AE during follow‐up. © 2015 Wiley Periodicals, Inc.
Embolization of Veno-venous Collaterals after the Fontan Operation Is Associated with Decreased Survival
Poterucha, Joseph T., Johnson, Jonathan N. , Taggart, Nathaniel W. , Hagler, Donald J. , Driscoll, David J. , Cetta, Frank , Taggart, Nathan W, Cabalka, Allison K. , Taggart, Nathaniel W

Congenital Heart Disease | May 23, 2015 | Volume: 10 | Issue: 5 | Pages: E230-E236

10.1111/chd.12276 Get It