Back to Authors

Snozek, Christine L.H.

https://orcid.org/0000-0003-0769-7165

Mayo Clinic

Mayo Clinic in Arizona

Citations 34

Catecholamine Interference in Enzymatic Creatinine Assays
Saenger, Amy K., Lockwood, Christina M. , Snozek, Christine L.H. , Milz, Thomas C., Karon, Brad S. , Scott, Mitchell G., Jaffe, Allan S. , Jaffe, Allan S.

Clinical Chemistry | July 9, 2009 | Volume: 55 | Issue: 9 | Pages: 1732-1736

10.1373/clinchem.2009.127373 Get It

Abstract Background: Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigation into interference of catecholamines with enzymatic methods. Methods: Spiked solutions of dopamine, dobutamine, epinephrine, and norepinephrine were added to pooled sera at catecholamine concentrations consistent with clinically relevant dosing. Creatinine was measured enzymatically on the Roche P-Modular, Ortho Clinical Diagnostics Vitros 350, and Abbott i-STAT. Jaffe methods were performed on the Roche P-Modular and Siemens Dimension RxL. In 10 patients receiving dopamine and/or dobutamine via a venous or arterial line we evaluated and compared the extent of in vivo creatinine interference in paired serum samples obtained by venipuncture and from indwelling catheters. Results: All catecholamines caused significant negative interference with the Roche enzymatic creatinine assay, most pronounced for dopamine and dobutamine. The Vitros enzymatic assay demonstrated slight negative interferences, and i-STAT enzymatic and Jaffe methods were unaffected by the presence of catecholamines. Significant (P < 0.001) differences in creatinine concentrations by Roche enzymatic vs Jaffe methods were observed in venipuncture specimens compared with arterial or venous catheter specimens, suggesting dopamine and dobutamine reversibly adhere to the catheter lumen. Conclusions: Negative interferences were pronounced for Roche enzymatic results in blood samples obtained from indwelling catheters, a phenomenon not observed in peripheral draws. Physicians and laboratorians should be alert to the possibility of a falsely low creatinine result and reevaluate questionable samples using a method unaffected by catecholamines.
Clinical Impact of Discordance in Serum Albumin Measurements on Myeloma International Staging System
Kapoor, Prashant , Snozek, Christine L.H. , Colby, Colin , Katzmann, Jerry A., Greipp, Philip R., Larson, Dirk R. , Rajkumar, S. Vincent

Journal of Clinical Oncology | August 18, 2008 | Volume: 26 | Issue: 24 | Pages: 4051-4052

10.1200/jco.2008.18.5082 Get It

Serum Thyroglobulin, High-Resolution Ultrasound, and Lymph Node Thyroglobulin in Diagnosis of Differentiated Thyroid Carcinoma Nodal Metastases
Snozek, Christine L.H. , Chambers, Eugene P., Reading, Carl C., Sebo, Thomas J., Sistrunk, J. Woody, Grebe, Stefan K., Singh, Ravinder

The Journal of Clinical Endocrinology & Metabolism | August 8, 2007 | Volume: 92 | Issue: 11 | Pages: 4278-4281

10.1210/jc.2007-1075 Get It

Comparison of Bromcresol Green and Agarose Protein Electrophoresis for Quantitation of Serum Albumin in Multiple Myeloma
Snozek, Christine L.H. , Saenger, Amy K., Greipp, Philip R., Bryant, Sandra C. , Kyle, Robert A. , Rajkumar, S. Vincent , Katzmann, Jerry A., Rajkumar, S Vincent

Clinical Chemistry | April 26, 2007 | Volume: 53 | Issue: 6 | Pages: 1099-1103

10.1373/clinchem.2007.088252 Get It

Abstract Background: The International Staging System for multiple myeloma has increased the importance of accurate measurement of serum albumin. Two common albumin assays, bromcresol green (BCG) and agarose gel protein electrophoresis (PEL), frequently yield discordant results, creating confusion regarding which assay is superior for use in myeloma. Methods: We measured albumin by BCG on a Roche Modular system, by PEL with a Helena SPIFE SPE Vis agarose gel, and by immunonephelometry performed on a Dade Behring BNII nephelometer. BCG and PEL were used to measure albumin in 5777 patient samples, and all 3 methods were used in an additional 252 samples. The clinical impact was assessed on 698 myeloma patient samples. Results: For sera with zero/low monoclonal immunoglobulin protein (M)-spike (0 to <15 g/L), results for both BCG and PEL correlated well to nephelometry, although median PEL results were 8 g/L lower than corresponding BCG measurements. Correlation between PEL and nephelometry or BCG diminished with increasing M-spike, with PEL eventually overestimating albumin compared with both other assays. IgG and IgA M-spikes showed significantly different effects on albumin discordance. For 35% of myeloma patients, discrepancy between BCG and PEL had a potentially clinically significant effect on staging, but no difference in group survival was found. Conclusions: Both BCG and PEL correlate well to nephelometry in sera with zero/low M-spikes. In the presence of larger M-spikes, PEL correlates poorly to nephelometry or BCG, whereas BCG compares well with nephelometry regardless of M-spike. Thus, albumin measurement can be performed reliably in myeloma patient sera by use of inexpensive, automated BCG assays.