Background Lower extremity salvage following significant soft tissue loss can be complicated by lack of recipient vessel for free tissue transfer. We describe our experience in lower limb salvage for patients with no recipient vessels with the use of pedicle, free and cable bridge flaps. Methods A retrospective review from 1985 to 2017 of patients undergoing lower limb salvage using a contralateral pedicle cross leg (PCL) flaps, free cross leg (FCL) flaps, or free cable bridge (FCB) flaps was conducted. Demographics, etiology of the reconstruction, type of flap used, donor-site vessels, defect size, operating time, time of pedicle division, length of hospital stay, time to ambulation, and complications were analyzed. Results A total of 53 patients (48 males and 5 females) with an average age of 35 years (range, 29–38 years) were identified. The etiology for the reconstruction was trauma in 52 patients and oncological resection in 1 patient. There were 18 PCL, 25 FCL, and 10 FCB completed. The recipient vessels for all flaps were the posterior tibial artery and vein. The average operating room times for PCL, FCL, and FCB flaps were 4, 9, and 10 hours, respectively. The average length of hospital stay was 5 weeks and average time to ambulation was 4 weeks. The average follow-up time was 7.5 years (range, 3–12 years). Complications encountered were hematoma (six), prolonged pain (six), total flap loss (two), reoperation (five), and infection (four). Limb salvage rates were 96.2%. Conclusion When ipsilateral limb vessels are not available, and other reconstructive options have been exhausted, cross leg flaps can be a viable option for limb salvage in the setting of extensive defects.
Long-Term Outcomes of Pedicled Gastrocnemius Flaps in Total Knee Arthroplasty
Background: Deficient soft tissue following total knee arthroplasty (TKA) can jeopardize outcome. The gastrocnemius flap is an important means of providing coverage of a knee with deficient soft tissue. There is a paucity of long-term studies on the use of the gastrocnemius flap in the setting of TKA. The purpose of this study was to review the outcomes after the use of pedicled gastrocnemius flaps for coverage of a soft-tissue defect at the time of TKA. Methods: Eighty-three patients in whom a gastrocnemius flap had been used to cover the site of a primary (n = 18) or revision (n = 65) TKA over a 25-year period were identified. There were 48 women (58%) and 35 men (42%) with a mean age and body mass index (BMI) of 65 years and 32.6 kg/m 2 . The mean wound size was 49 cm 2 , and the wound was most commonly located over the anterior aspect of the knee/patellar tendon (n = 33). Patients were followed to the time of implant or flap revision, amputation, or death or for a minimum of 2 years (mean, 8 years). Clinical outcomes were assessed using the Knee Society Score (KSS) for pain and the KSS for function. The Kaplan-Meier method was used to assess revision and amputation-free survival. Risk factors for amputation and revision were identified with Cox regression. Results: The 10-year revision and amputation-free survival rates following gastrocnemius flap coverage were 68% and 79%, respectively. The risk of implant failure was increased by morbid obesity (BMI of ≥40 kg/m 2 ) (hazard ratio [HR] = 2.82, 95% confidence interval [CI] = 1.09 to 7.32, p = 0.03) and ≥5 prior surgical procedures on the knee (HR = 2.68, 95% CI = 1.04 to 6.88, p = 0.04). The risk of amputation was increased in patients with ≥5 prior surgical procedures (HR = 10.76, 95% CI = 2.38 to 48.58, p = 0.002), an age of ≥65 years (HR = 4.94, 95% CI = 1.10 to 22.09, p = 0.03), and a wound size of ≥50 cm 2 (HR = 3.29, 95% CI = 1.14 to 9.53, p = 0.02). Preoperatively the mean KSSs for pain and function were 46 and 28, and these scores significantly (p < 0.05) improved to 78 and 43, respectively, at the time of follow-up. Conclusions: The gastrocnemius flap reliably provides coverage of components used in complex knee reconstruction. A history of multiple surgical procedures on the knee and larger soft-tissue defects increase the risk of revision TKA and of amputation. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Novel engineered tendon-fibrocartilage-bone composite with cyclic tension for rotator cuff repair
Background: Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Methods: Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. Results: The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. Conclusions: FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Clinical Relevance: Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.
Diagnosis and management of hook of hamate fractures
The purpose of this study was to evaluate the time to diagnosis and management of hook of hamate fractures in an era of advanced imaging. We performed a retrospective study of 51 patients treated for hook of hamate fractures. Patients were sent a quickDASH questionnaire regarding the outcomes of their treatment. Hook of hamate fractures were diagnosed with advanced imaging at a median of 27 days. Clinical findings of hook of hamate tenderness had better sensitivity than carpal tunnel-view radiographs. Nonunion occurred in 24% of patients with non-operative treatment and did not occur in the operative group. Both treatment groups achieved good clinical results, with a grip strength of 80% compared with the non-injured hand and a median quickDASH score of 2. Advanced imaging improved the time to diagnosis and treatment compared to historical case series. Nonunion is common in patients treated non-operatively. Level of evidence: IV
The effect of full dose composite tissue allotransplantation immunosuppression on allograft motor nerve regeneration in a rat sciatic nerve model
BackgroundThe purpose of this study was to identify which triple immunosuppressive protocols, currently used for vascularized composite allotransplantation in the clinic, will have the best effect on motor function recovery following nerve allograft reconstruction.MethodsEighty‐eight Lewis rats underwent a 1‐cm sciatic nerve allograft transplantation and skin graft from 44 Brown‐Norway rats. Group I received 0.9% isotonic saline (control); Group II, 2 mg/kg FK506; Group III, 1 mg/kg FK506 with 15 mg/kg mycophenolate mofetil (MMF); and Group IV, 2 mg/kg FK506 with 30 mg/kg MMF and prednisone. Each group consisted of 11 rats. After 12 weeks, motor function recovery was evaluated with isometric tetanic force, muscle mass, ankle contracture angle, electrophysiology, and nerve histomorphometry. Adequacy of immunosuppression was monitored with the transplanted skin graft. All data are expressed as a percentage of the contralateral side.ResultsIsometric tetanic force showed significantly better functional recovery in all groups treated with immunosuppression compared to control. Within the immunosuppression groups no significant difference was found: 42.1 ± 6.4% (Group I), 56.1 ± 12.4% (Group II), 58.4 ± 10.7% (Group III), and 61.3 ± 11.2% (Group IV). Group IV was superior to all other groups regarding ankle contracture (P < .05) and electrophysiology (P < .001). Skin graft rejection occurred in 41 and 0% (Groups III and IV, respectively).ConclusionsFK506 significantly enhanced motor recovery after allograft reconstruction. This effect was comparable between combination treatment (low‐dose FK506 and MMF) and triple therapy (high‐dose FK506 and MMF plus prednisolone). However, triple therapy was more effective in suppressing skin rejection.
Rotator cuff repair with a novel mesh suture: An ex vivo assessment of mechanical properties
Outcomes and Complications of Reconstruction with Use of Free Vascularized Fibular Graft for Spinal and Pelvic Defects Following Resection of a Malignant Tumor
Background: Following resection of malignant tumors of the spine and pelvis, reconstructive surgeons often face large structural defects. Unlike reconstruction in the extremities, wherein a free vascularized fibular graft (FVFG) is a highly utilized option for segmental osseous reconstruction, there are limited data on the use of an FVFG in the spine and pelvis. The aim of this study was to review our institution’s experience with reconstruction with use of an FVFG following oncological resection in the spine and pelvis. Methods: We reviewed 24 cases involving the use of an FVFG in reconstruction of segmental osseous defects of the spine and pelvis following oncological resection from 2000 to 2015. The cohort consisted of 12 male and 12 female patients with a mean age of 37 years and a mean follow-up of 5 years. Fifty-four percent of the reconstructions were spinopelvic or sacropelvic. Results: The overall 2, 5, and 10-year rate of survival was 76%, 55%, and 37%, respectively. With regard to disease-free survival, the overall 2, 5, and 10-year rate was 81%, 72%, and 48%. The overall rate of union was 86%, with a mean time to union of 7 months. Complications were common, with 83% of the patients sustaining at least 1 postoperative complication. Following the procedure, the mean Musculoskeletal Tumor Society rating was 53%. Conclusions: An FVFG provides a durable means of reconstruction of osseous defects in the spine and pelvis. Although patient function was acceptable following these large reconstructions, the rate of postoperative complications was high. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Advances in peripheral nerve regeneration as it relates to VCA