PurposeTo demonstrate the feasibility of pseudo‐continuous arterial‐spin–labeled (pCASL) imaging with 3D fast‐spin‐echo stack‐of‐spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy‐current–induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion‐related images with high‐performance gradients (80 mT/m, 700T/m/s) of the C3T.MethodsTo track eddy‐current–induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density‐compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion‐weighted (ΔM) images and proton‐density–weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers.ResultsBlurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal‐to‐noise ratio of ΔM images improved, on average, by 7.6% after correction (P < .001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s.ConclusionEddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax. The trajectory correction for spiral‐readout–based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high‐performance gradients.
Distortion‐free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion‐free high‐resolution diffusion imaging on a compact 3T with high‐performance gradients
BackgroundDistortion‐free, high‐resolution diffusion imaging using DIADEM (Distortion‐free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated.PurposeTo investigate the clinical feasibility of DIADEM‐based high‐resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high‐performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging.Study TypeProspective feasibility study.Phantom/SubjectsDiffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0‐field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging.Field Strength/Sequence3T; the standard single‐shot echo‐planar‐imaging (EPI), multishot DIADEM diffusion, and anatomical (2D‐FSE [fast‐spin‐echo], 2D‐FLAIR [fluid‐attenuated‐inversion‐recovery], and 3D‐MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging.AssessmentThe scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high‐resolution diffusion imaging in healthy control and brain tumor volunteers.Statistical TestBland–Altman analysis.ResultsThe scan time for high in‐plane (0.86 mm2) resolution, distortion‐free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland–Altman plot. The proposed acquisition with a total off‐resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion‐free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries.Data ConclusionThe proposed high‐resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements.Level of Evidence3Technical EfficacyStage 1 J. Magn. Reson. Imaging 2020;51:296–310.